Search results for "ocular"
showing 10 items of 1219 documents
Changes in anterior chamber eye during accommodation as assessed using a Dual Scheimpflug system
2014
Purpose: To study the changes in anterior chamber depth (ACD), anterior chamber angle (ACA), and pupil diameter (PD) during accommodation. Methods: Eighty eyes of 80 subjects, aged 22 to 40 years, were included. The rotating Dual Scheimpflug and a Placido disc system (Galilei G4, Ziemer Ophthalmic Systems AG, Switzerland) was used to measure the changes in ACD, ACA, and PD during accommodation. ACD measurement was taken for the central zone and for 4 more positions, each in different orientation (nasal, superior, temporal and inferior), 4 mm away from the centre. ACA was measured for the whole eye as well for the nasal, superior, temporal, and inferior quadrants. These metrics were obtained…
Multisectorial changes in the ciliary muscle during accommodation measured with high-resolution optical coherence tomography
2019
ABSTRACT Purpose: To measure changes in the anterior ciliary muscle during accommodation at the nasal, superior, temporal, and inferior sectors by means of an anterior chamber optical coherence tomographer, and correlate them with vergence changes. Methods: Twenty-four subjects with healthy, phakic eyes, whose mean age was 27.1 ± 8.9 years, underwent measurement with an anterior chamber optical coherence tomographer. The anterior ciliary muscle was measured at the nasal, temporal, superior, and inferior sectors for 0, -1, -2, and -3 D of vergence. A linear model was used to assess the correlation of each eye parameter with the accommodative demand. Results: The anterior ciliary muscle area …
Comparison of visual and refractive results of Toric Implantable Collamer Lens with bioptics for myopic astigmatism.
2013
PURPOSE: To compare visual and refractive results of Toric Implantable Collamer Lens (TICL) and bioptics (ICL plus excimer corneal surgery) to treat myopic astigmatism. METHODS: Eighty-one eyes underwent TICL implantation and 83 eyes were treated with bioptics (corneal ablation was performed between 1.5 and 6 months after ICL implantation). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refraction, adverse events, safety, and efficacy were evaluated 12 months postoperatively. RESULTS: At 12 months postoperatively, the mean spherical equivalent was -0.15 ± 0.36 diopters (D) in the TICL group and -0.08 ± 0.26 D in the bioptics group (p = 0.099). Sixty-six …
Seventh nerve palsies may be the only clinical sign of small pontine infarctions in diabetic and hypertensive patients
2002
Backgroud: Small brainstem infarctions are increasingly recognized as a cause of isolated ocular motor and vestibular nerve palsies in diabetic and/or hypertensive patients. This raises the question whether there are also isolated 7th nerve palsies due to pontine infarctions in patients with such risk factors for the development of cerebrovascular diseases. Methods: Over an 11-year-period, we retrospectively identified 10 diabetic and/or hypertensive patients with isolated 7th nerve palsies and electrophysiological abnormalities indicating pontine dysfunction. All patients had examinations of masseter and blink reflexes, brainstem auditory evoked potentials, direct current electro-oculograp…
Sutureless ciliary sulcus supported intraocular lens with transiridal anchoring haptics.
2003
We report a technique for implanting intraocular lenses (IOLs) in the ciliary sulcus in eyes without capsule support. The IOL design allows it to be implanted without fixation sutures. The lens was implanted in 3 aphakic eyes without capsule support.
How Do Different Digital Displays Affect the Ocular Surface?
2020
Digital display use has been accepted as a contributing factor to dry eye disease. Nowadays, plenty of new models of digital displays have been developed, and the differences in their nature and the ways in which they are set and used may contribute to differences in the eye-related problems they cause.This study aimed to analyze the differences in ocular surface, tear film, and visual fatigue parameters after reading on different digital displays, with and without initial instillation of artificial tears.Thirty-one healthy individuals ranging in age from 20 to 26 years (mean ± standard deviation, 21.26 ± 1.73 years) were included in this prospective clinical study. Subjects' ocular surface…
Single versus double femtosecond laser pass for incomplete laser in situ keratomileusis flap in contralateral eyes: Visual and optical outcomes
2011
Purpose To evaluate visual acuity, refractive outcomes, and anterior corneal higher-order aberrations (HOAs) after myopic laser in situ keratomileusis (LASIK) with uneventful single femtosecond laser pass versus double pass performed for intraoperative suction loss. Setting Private refractive surgery center, Valencia, Spain. Design Cohort study. Methods After the LASIK flap was created with a single pass of an Intralase femtosecond laser in 1 eye and a double pass in the fellow eye, the ablation was performed with a Visx S2 laser. At 12 months, the refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, and anterior corneal HOAs were measured with 4.0 mm and 6.0 mm pup…
Scheimpflug biometry of the anterior segment after implantation of foldable iris-fixated lenses.
2006
ABSTRACT PURPOSE: To evaluate intraocular dimensions of the anterior segment of myopic phakic eyes after implantation of foldable iris-fixated lenses. METHODS: Seventeen myopic eyes that received a foldable iris-fixated phakic intraocular lens (PIOL) were assessed. Distances between the cornea and the IOLoptic edge and between the IOL optic and the crystalline lens were evaluated using Scheimpf lug photography 3 months postoperatively. RESULTS: The average postoperative distance between the central corneal endothelium and the anterior surface of the IOL was 2.01±0.26 mm. The distance between the corneal endothelium and the peripheral edge of the IOL averaged 1.32±0.18 mm at the 12 o'clock p…
Effects of intraocular cefotaxime on the human corneal endothelium
2001
Abstract Purpose To ascertain whether 0.4 mL of cefotaxime 0.25% applied intracamerally causes toxic alteration of the human corneal endothelium. Methods In this prospective randomized masked study, 66 patients had cataract extraction using phacoemulsification, a frown incision, and implantation of a poly(methyl methacrylate) intraocular lens. This was followed by intraocular injection of 0.4 mL of cefotaxime 0.25% or balanced salt solution (BSS®). Contact specular microscopy and photography were performed preoperatively and 1 to 4 days and 3 months postoperatively. Results In the cefotaxime group, the mean endothelial cell count was 2729 cells/mm 2 ± 474 (SD) preoperatively, 2520 ± 462 cel…
Changes in the anterior chamber during accommodation assessed with a Scheimpflug system.
2014
Purpose To study changes in the anterior chamber depth (ACD), anterior chamber angle, and pupil diameter with accommodation. Setting University of Valencia, Valencia, Spain. Design Evaluation of diagnostic technology. Methods A rotating Scheimpflug camera (Pentacam HR) was used to measure changes in the ACD, anterior chamber angle, and pupil diameter with accommodation. Peripheral ACD was measured at the corneal center and 2.0 mm away from it in the nasal, superior, temporal, and inferior directions. The anterior chamber angle was computed as the mean anterior chamber angle of the entire eye. All measurements were obtained with accommodation stimuli ranging from +1.0 to −4.0 diopters (D) in…