Search results for "ocular"
showing 10 items of 1219 documents
Effects of LASIK on Corneal Endothelium Using the 15-kHz IntraLase Femtosecond Laser
2011
PURPOSE: To assess the effects of LASIK with the 15-kHz IntraLase femtosecond laser on corneal endothelium. METHODS: In a prospective, single-center clinical trial, 138 patients (mean age: 32.0±7.1 years [range: 21 to 42 years]) underwent femtosecond LASIK for the correction of myopia −0.75 to −9.00 diopters (D) and cylinder up to 3.25 D. Patients were divided into two groups: contact lens group (n=76) and non-contact lens group (n=62). Pre- and 12-month postoperative specular microscopy of the central corneal endothelium was performed. The integrity of the central endothelium was assessed in terms of endothelial cell density and percentage of hexagonality. RESULTS: In the contact lens gro…
Online Vs In-person Education: Evaluating the Potential Influence of Teaching Modality on Dry Eye Symptoms and Risk Factors During the COVID-19 Pande…
2021
OBJECTIVES: To assess the potential effects of switching to online lecture format on dry eye symptoms and dry eye disease (DED) risk factors. METHODS: An anonymous cross-sectional online survey was conducted in 812 university students (mean age, 21.5±4.0 years). Participants were classified according to the number of hours the participants took online lectures into online students or in-person students. Respondents completed a total of three DED questionnaires (Ocular Surface Disease Index [OSDI]; 5-item Dry Eye Questionnaire; 8-item Contact Lens Dry Eye Questionnaire) and were surveyed on dry eye risk factors contemplated by the Tear Film and Ocular Surface Society Dry Eye Workshop II in a…
Visual performance with simultaneous vision multifocal contact lenses.
2011
Purpose: The aim was to assess visual performance after PureVision high addition multifocal contact lens (PM) fitting through contrast sensitivity measured under different illumination levels for both distance and near. Methods: In a cross-over study, 20 presbyopic patients were randomly assigned to PM or spectacles. Near contrast sensitivity was measured with the Vistech VCTS 6500 system. Distance contrast sensitivity and distance visual acuity (VA) were measured with the Functional Vision Analyser under photopic (85 cd/m2) and mesopic (3.0 cd/m2) conditions, the latter also under two levels of induced glare: 1.0 lux and 28 lux. Near VA was measured by logMAR charts under approximately 8…
Collagen copolymer posterior chamber phakic intraocular lens for hyperopia correction: three-year follow-up.
2013
Purpose To assess the efficacy, predictability, safety, and stability of the Visian V3 Implantable Collamer Lens posterior chamber phakic intraocular lens (PC pIOL) for moderate to high hyperopia. Setting Private clinic, Oviedo, Spain. Design Prospective nonrandomized clinical study. Methods The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, manifest refraction, endothelial cell density, intraocular pressure (IOP), central vault, and adverse events were evaluated for 3 years postoperatively. Results The study comprised 73 eyes of 44 patients. The mean spherical equivalent decreased from +4.84 diopters (D) ± 1.6 (SD) (range +1.00 to +7.75 D) preoperatively to −0.13 ± 0.39 …
A European Study of the Performance and Safety of MINIject in Patients With Medically Uncontrolled Open-angle Glaucoma (STAR-II)
2020
Precis In this European study (STAR-II), MINIject, a novel, ab-interno, supraciliary MIGS device, effectively lowered intraocular pressure (IOP) and the need for IOP-lowering medications in patients with primary open-angle glaucoma. Purpose To evaluate the safety and performance of a minimally invasive supraciliary glaucoma drainage device (MINIject DO627, iSTAR Medical SA, Wavre, Belgium) for surgical treatment of primary open angle glaucoma in patients refractory to topical hypotensive medications. Methods In a prospective, interventional, single-arm, multi-center, European study (STAR-II), MINIject was successfully implanted in a standalone procedure in 29 of 31 patients in 8 sites in 3 …
Peripheral corneal thickness and associated factors - results from the population-based German Gutenberg Health Study.
2021
PURPOSE Changes in peripheral corneal thickness are described in various corneal diseases such as corneal ectasia. However, few data exist describing the increase in corneal thickness from central to peripheral and reporting the normal distribution of corneal thickness in rings around the corneal centre. The aim of this study was to report these cornea characteristics and investigate associated factors in a population-based setting. METHODS The Gutenberg Health Study is a prospective, population-based study examining participants in a 5-year follow-up (age range 40-80 years) using Scheimpflug imaging. Corneal thickness was assessed in each participant at the apex, as well as in the corneal …
Behaviour of the phakic iris-claw intraocular lens (Artisan /Verisyse) during accommodation: an optical coherence biometry study.
2007
Purpose To evaluate variations in the position of the phakic iris claw lens (Artisan®, Verisyse®) and the natural crystalline lens during the accommodation process. Methods We measured changes in position of the iris claw lens and the crystalline lens during the accommodation using optical coherence biometry (AC Master®/Carl Zeiss Meditec, Germany) in 17 patients (28 eyes) with a phakic iris claw lens implanted for high myopia and/or myopic astigmatism. Accommodative effort was obtained using an internal optical target within the measuring device. Results There was a forward shift of the phakic iris claw lens with a mean of 70 μm (8–178 μm) of the optical path length (OPL). At the same time…
Prevalence of general binocular dysfunctions in a population of university students.
1997
Although some authors report that the prevalence of general binocular dysfunctions (nonstrabismic) for nonpresbyopes in the clinical population is greater than any condition except refractive error, limited research is available to support this statement. This clinical study determined the presence and clinical implications of these conditions in a population of university students with heavy near visual demands.From a group of second year students who were given a thorough eye examination, 65 students were selected. The criteria for selection were the absence of significant uncorrected refractive error, healthy eyes, and no strabismus or amblyopia.32.3% of the subjects showed general binoc…
Femtosecond laser versus mechanical keratome LASIK for myopia.
2005
To assess efficacy, safety, predictability, stability, and changes in corneal higher-order aberrations (CHOAs) and contrast sensitivity (CS) after a femtosecond laser for LASIK and standard LASIK for myopia.Prospective, randomized, comparative clinical study.Two hundred eyes of 100 consecutive patients who underwent LASIK treatment using the VISX S2 laser system. A femtosecond laser for flap creation was used in 100 eyes (50 patients; spherical equivalent [SE], -2.85+/-1.79 diopters [D]), and a mechanical microkeratome was used in 100 eyes (50 patients; SE, -2.90+/-1.63 D).Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest refraction, CS by means of t…
Learning Curve and Fatigue Effect of Flicker Defined Form Perimetry
2011
To evaluate the learning curve and fatigue effect of flicker defined form (FDF) perimetry.Prospective cross-sectional study.One hundred forty-one eyes of 75 healthy subjects were included in the study. Every subject was measured 3 times on 3 different days within 3 months. Differences among the tests were analyzed for mean sensitivity (MS), mean deviation (MD), pattern standard deviation (PSD), reliability indices, test duration, and test points5% and0.5% in 75 right eyes on the basis of linear mixed models for repeated measurements. To assess the effect of fatigue, differences of MS, MD, and PSD values between 66 left and right eyes were evaluated regarding alterations between these 3 exam…