Search results for "ocular"

showing 10 items of 1219 documents

Addition of a fixed combination of brinzolamide 1%/timolol 0.5% to prostaglandin monotherapy in patients with glaucoma or ocular hypertension

2011

Katrin Lorenz1, Klaus Rosbach2, Andreas Matt3, Norbert Pfeiffer11University Medical Center, Johannes Gutenberg-Universität Mainz, Mainz, Germany; 2Private practice, Mainz, Germany; 3Private practice, Köln-Hohenhaus, GermanyBackground: This study was conducted to evaluate the safety and efficacy of adding a fixed combination of brinzolamide 1%/timolol 0.5% to prostaglandin analog (PGA) monotherapy in patients with primary open-angle glaucoma, pigment dispersion glaucoma, or ocular hypertension who require additional intraocular pressure (IOP) reduction.Methods: This was a prospective, multicenter (n = 5), open-label, single-arm, Phase IV clinical trial in which patients cur…

Intraocular pressuremedicine.medical_specialtygenetic structuresadjunctive therapyfixed combinationBrinzolamideTimololGlaucomaOcular hypertensionOphthalmologyMedicineAdverse effectcarbonic anhydrase inhibitorOriginal Researchbusiness.industryClinical OphthalmologyRE1-994medicine.diseasebrinzolamideeye diseasesDiscontinuationOphthalmologyProstaglandin analogglaucomasense organsbusinessmedicine.drugintraocular pressureClinical Ophthalmology
researchProduct

Acute endothelial failure after cosmetic iris implants (NewIris®)

2011

We report a case of an acute endothelial failure after the implantation of a new cosmetic, colored, artificial iris diaphragm implant called NewIris(®). A 21-year-old woman came to us complaining of progressive loss of vision and pain after NewIris lenses had been implanted. Decreased visual acuity, corneal edema, and increased intraocular pressure in both eyes appeared only 3 weeks after the surgery. The lenses were removed as soon as possible but had already severely affected the endothelial cell count. NewIris implants are an alternative to cosmetic contact lenses, but they are not as safe as other phakic anterior chamber intraocular lenses, nor are they a good option for the patient.

Intraocular pressuremedicine.medical_specialtygenetic structuresbusiness.industryCase Reportendothelial failureNewIrisEndothelial cell counteye diseasescosmetic iris implantsSurgeryOphthalmologymedicine.anatomical_structureCorneal edemaIntraocular lensesOphthalmologyDecreased Visual AcuitymedicineImplantsense organsIris (anatomy)businessClinical Ophthalmology (Auckland, N.Z.)
researchProduct

Spurectomy: A novel modification of non-penetrating deep sclerectomy.

2020

To evaluate the outcomes of a novel modification of the non-penetrating deep sclerectomy (NPDS) approach for glaucoma management called spurectomy.Observational comparative non-randomized retrospective study including 98 glaucomatous eyes of 76 patients operated on with the spurectomy technique consisting of the combination of the excision of the scleral spur with NPDS (groupA). A control group (groupB) including 53 glaucomatous eyes of 43 patients operated on with classical NPDS was also included. Changes in intraocular pressure (IOP) and medications required as well as complications were recorded in a 12-month follow-up.Mean IOP decreased from 25.69±8.11 preoperatively to 15.73±4.16mm Hg …

Intraocular pressuremedicine.medical_specialtygenetic structuresbusiness.industryScleral spurGlaucomaRetrospective cohort studyGeneral Medicine030204 cardiovascular system & hematologymedicine.diseaseDeep sclerectomyMethods observationaleye diseases03 medical and health sciences0302 clinical medicinemedicine.anatomical_structureCirugía de glaucoma no perforante Drenaje supracoroideo Espolonectomía Implante supraciliar Non-penetrating glaucoma surgery Spurectomy Suprachoroidal outflow Supraciliar implantOphthalmology030221 ophthalmology & optometrymedicinesense organsbusinessArchivos de la Sociedad Espanola de Oftalmologia
researchProduct

2021

AIM: To investigate short- and long-term intraocular pressure (IOP) fluctuations and further ocular and demographic parameters as predictors for normal tension glaucoma (NTG) progression. METHODS: This retrospective, longitudinal cohort study included 137 eyes of 75 patients with NTG, defined by glaucomatous optic disc or visual field defect with normal IOP (<21 mm Hg), independently from therapy regimen. IOP fluctuation, mean, and maximum were inspected with a mean follow-up of 38mo [standard deviation (SD) 18mo]. Inclusion criteria were the performance of minimum two 48-hour profiles including perimetry, Heidelberg retina tomograph (HRT) imaging, and optic disc photographs. The impact …

Intraocular pressuremedicine.medical_specialtygenetic structuresbusiness.industryeye diseasesVisual fieldOphthalmologymedicine.anatomical_structureNormal tension glaucomaOphthalmologyVisual field testingMedicinesense organsLongitudinal cohortbusinessHeidelberg retina tomographOptic discInternational Journal of Ophthalmology
researchProduct

An invasive species may be better than none: invasive signal and native noble crayfish have similar community effects

2014

14 pages; International audience; Human activities have resulted in the decline of native crayfish and promoted the spread of invasive crayfish species in European fresh waters, threatening ecosystem structure and functioning. We compared effects of native noble crayfish (Astacus astacus), invasive signal crayfish (Pacifastacus leniusculus) and of the absence of crayfish on leaf litter breakdown and invertebrate prey density and biomass in stream ecosystems. In microcosm experiments, invertebrate shredder density was significantly reduced by crayfish presence but similarly affected by the two crayfish species. While crayfish did not directly influence leaf litter breakdown, their presence r…

Introduced speciesAquatic Sciencelitter breakdownPacifastacusSignal crayfishPredationinvasive species[SDV.EE.ECO]Life Sciences [q-bio]/Ecology environment/Ecosystems14. Life underwaterShellfish[ SDE.BE ] Environmental Sciences/Biodiversity and EcologyAstacusbiologycrayfishEcologymusculoskeletal neural and ocular physiology15. Life on landPlant litterbiology.organism_classificationCrayfish[ SDV.EE.ECO ] Life Sciences [q-bio]/Ecology environment/Ecosystems6. Clean water[SDV.BA.ZI]Life Sciences [q-bio]/Animal biology/Invertebrate ZoologyPacifastacus leniusculusnervous system[SDE.BE]Environmental Sciences/Biodiversity and EcologyAstacus astacus
researchProduct

Some thoughts about the conceptual / procedural distinction in translation: a key-logging and eye-tracking study of processing effort

2014

This article builds on the conceptual / procedural distinction postulated by Relevance Theory to investigate processing effort in translation task execution. Drawing on relevance-theoretic assumptions, it assumes that instances related to procedural encodings will require more effortful processing not only in relation to the time spent on the task but also in terms of product indicators such as seconds per word and number of micro translation units per word. Drawing on key-logging and eye-tracking data, the article shows that there are statistically significant differences when conceptual and procedural encodings are analysed in selected areas of interest, with instances related to procedur…

Key loggingSeguimiento ocular (eye tracking)Linguistics and LanguageTranslation process research; Relevance Theory; Conceptual; Procedural distinction; Key logging; Eye trackingCodificación conceptual / procedimentalRelation (database)Computer scienceRelevance TheoryRegistros de teclado y ratón (key logging)computer.software_genreKeystroke loggingLanguage and LinguisticsEducationTask (project management)Encoding (semiotics)Teoría de la RelevanciaUNESCO::CIENCIAS DE LAS ARTES Y LAS LETRASEye trackingProceso de traducción; Teoría de la Relevancia; Codificación conceptual / procedimental; Registros de teclado y ratón (key logging); Seguimiento ocular (eye tracking)business.industryRelevance theorySIGNAL (programming language)Traducción e InterpretaciónTranslation process researchProceso de traducción:CIENCIAS DE LAS ARTES Y LAS LETRAS [UNESCO]Eye trackingArtificial intelligenceConceptual / procedural distinctionbusinesscomputerNatural language processingWord (computer architecture)MonTI. Monografías de Traducción e Interpretación
researchProduct

Posterior chamber phakic intraocular lenses after penetrating keratoplasty.

2009

Purpose To evaluate the efficacy, predictability, and safety of a phakic posterior chamber intraocular Collamer lens (ICL) after penetrating keratoplasty (PKP). Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Methods A myopic or toric ICL was implanted after PKP in eyes unable to wear glasses or contact lenses and for which corneal laser surgery was contraindicated. The uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refractive error, and endothelial cell count were recorded preoperatively and 24 months postoperatively. Results Preoperatively, the 15 eyes had myopia from −2.00 to −17.00 diopters (D) or astigmatism from −1.50 to −7.00 D. …

Laser surgeryAdultMaleRefractive errormedicine.medical_specialtyPhakic Intraocular Lensesgenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensCell CountAstigmatismPhakic intraocular lensSafety indexPostoperative ComplicationsLens Implantation IntraocularRefractive surgeryOphthalmologymedicineMyopiaHumansProspective StudiesDioptrebusiness.industryEndothelium CornealAstigmatismMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologyTreatment OutcomeSurgeryFemalesense organsbusinessKeratoplasty PenetratingJournal of cataract and refractive surgery
researchProduct

Femtosecond laser for residual refractive error correction after refractive lens exchange with multifocal intraocular lens implantation.

2008

Purpose To assess visual and refractive outcomes of femtosecond laser for residual refractive error correction after refractive lens exchange (RLE) with multifocal intraocular lens (IOL) implantation. Design Prospective, nonrandomized, masked observational case series (self-controlled). Methods Fifty-three eyes of 31 consecutive patients were submitted to femtosecond laser surgery after RLE with multifocal IOL implantation. Patients showed an average manifest refractive error (D) of M , 0.200 ± 0.490; J 0 , −0.051 ± 0.532; and J 45 , −0.007 ± 0.371. Visual acuity (VA) was measured at distance and near vision before and six months after the surgery. Results At six months after surgery, mean …

Laser surgeryMalemedicine.medical_specialtyRefractive errorVisual acuitygenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituAcrylic ResinsVisual AcuityKeratomileusisIntraocular lensRefraction OcularPostoperative ComplicationsLens Implantation IntraocularOphthalmologymedicineMyopiaHumansProspective StudiesDioptreAgedLenses Intraocularmedicine.diagnostic_testbusiness.industryCorneal TopographyMultifocal intraocular lensMiddle AgedCorneal topographymedicine.diseasePrognosiseye diseasesOphthalmologyHyperopiaFemaleLasers Excimersense organsmedicine.symptombusinessFollow-Up StudiesAmerican journal of ophthalmology
researchProduct

Solvent for removing silicone oil from intraocular lenses: experimental study comparing various biomaterials.

2000

Abstract Purpose To evaluate the effectiveness of a perfluorocarbon—perfluorohexyloctane (PFHO)—in removing silicone oil from different intraocular lenses (IOLs) and determine whether any removal technique enhances the removal of silicone oil. Methods Six IOL materials were analyzed: standard poly(methyl methacrylate) (PMMA), heparin-surface-modified (HSM) PMMA, AcrySof, 2 polyHEMAs with different water contents, and a second-generation SLM-2 silicone. One or 2 μL of a highly viscous silicone oil (5700 cs) was applied to the center of each IOL optic. Perfluorohexyloctane (2 mL) was then used to remove the silicone oil by 1 of 3 techniques: immersion of the IOL in PFHO; irrigation of the sil…

Lens materialsmedicine.medical_specialtyMaterials scienceSurface Propertiesmedicine.medical_treatmentIntraocular lensBiocompatible Materialschemistry.chemical_compoundSiliconemedicineHumansPolymethyl MethacrylateSilicone OilsLenses IntraocularFluorocarbonsComputerized analysisBiomaterialAdhesivenessReproducibility of ResultsSensory SystemsSilicone oilSurgerySolventOphthalmologychemistryIntraocular lensesSolventsMethacrylatesSurgeryBiomedical engineeringJournal of cataract and refractive surgery
researchProduct

Compression forces of haptics of selected posterior chamber lenses

1997

Abstract Purpose: To compare the compressive forces of the haptics of different intraocular lens (IOL) models and analyze the observed differences. Setting: Central Hospital of Central Finland and University of Jyvaskyla, Jyvaskyla, Finland. Methods: The haptics of 28 IOL models were compressed to a diameter of 9.0 mm. The compression forces were measured at 0.5 mm intervals. The conclusions were verified by numerical simulations of mechanical models of the lenses. Results: The measured forces varied between 100 and 601 mg at a diameter of 11.0 mm, 206 and 1057 mg at a diameter of 10.0 mm, and 315 and 2094 mg at a diameter of 9.0 mm. The slopes of the force curves of the three-piece lenses …

Lenses IntraocularMaterials scienceCompressive Strengthbusiness.industryMechanical modelsmedicine.medical_treatmentIntraocular lensCompression (physics)Sensory SystemsForce curveslaw.inventionLens (optics)OphthalmologyOpticsCompressive strengthLens Implantation IntraocularlawmedicineSurgerybusinessBiomedical engineeringHaptic technologyJournal of Cataract and Refractive Surgery
researchProduct