Search results for "ophthalmologic"
showing 10 items of 49 documents
Measuring corneal clouding in patients suffering from mucopolysaccharidosis with the Pentacam densitometry programme
2013
Aim To identify a means to objectively measure corneal clouding in patients with mucopolysaccharidosis in a prospective controlled clinical trial. Methods Corneal haze was assessed by slit lamp examination and measured using the densitometry programme of the Pentacam, a rotating Scheimpflug camera in 33 mucopolysaccharidoses (MPS) patients and 32 controls. Results Pentacam measurements were available in 31 right and 31 left eyes of 32 patients and in 32 left and right eyes of 32 subjects in the control group. Slit lamp findings correlated very well with corneal density measurements (Spearman correlation right eye (OD)/left eye (OS)=0.782/0.791). MPS patients had higher density units (median…
Changes in anterior chamber eye during accommodation as assessed using a Dual Scheimpflug system
2014
Purpose: To study the changes in anterior chamber depth (ACD), anterior chamber angle (ACA), and pupil diameter (PD) during accommodation. Methods: Eighty eyes of 80 subjects, aged 22 to 40 years, were included. The rotating Dual Scheimpflug and a Placido disc system (Galilei G4, Ziemer Ophthalmic Systems AG, Switzerland) was used to measure the changes in ACD, ACA, and PD during accommodation. ACD measurement was taken for the central zone and for 4 more positions, each in different orientation (nasal, superior, temporal and inferior), 4 mm away from the centre. ACA was measured for the whole eye as well for the nasal, superior, temporal, and inferior quadrants. These metrics were obtained…
Comparison of Immersion Ultrasound, Partial Coherence Interferometry, and Low Coherence Reflectometry for Ocular Biometry in Cataract Patients
2011
PURPOSE: To compare ocular biometry parameters measured with immersion ultrasound, partial coherence interferometry, and low coherence reflectometry in cataract patients. METHODS: Measurements of axial length and anterior chamber depth were analyzed and compared using immersion ultrasound, partial coherence interferometry, and low coherence reflectometry. Keratometry (K), flattest axis, and white-to-white measurements were compared between partial coherence interferometry and low coherence reflectometry. Seventy-eight cataract (LOCS II range: 1 to 3) eyes of 45 patients aged between 42 and 90 years were evaluated. A subanalysis as a function of cataract degree was done for axial length and…
Changes in the anterior chamber during accommodation assessed with a Scheimpflug system.
2014
Purpose To study changes in the anterior chamber depth (ACD), anterior chamber angle, and pupil diameter with accommodation. Setting University of Valencia, Valencia, Spain. Design Evaluation of diagnostic technology. Methods A rotating Scheimpflug camera (Pentacam HR) was used to measure changes in the ACD, anterior chamber angle, and pupil diameter with accommodation. Peripheral ACD was measured at the corneal center and 2.0 mm away from it in the nasal, superior, temporal, and inferior directions. The anterior chamber angle was computed as the mean anterior chamber angle of the entire eye. All measurements were obtained with accommodation stimuli ranging from +1.0 to −4.0 diopters (D) in…
Comparison of cyclodeviation and duction measurement in Graves' orbitopathy patients using different devices
2011
To compare measurement outcomes of different devices measuring cyclodeviation and ductions in Graves' orbitopathy (GO) patients. Cyclodeviation in GO patients was measured using the Harms tangent screen (HTS), the cycloforometer of Franceschetti, and the synoptometer. Ductions were measured using the modified perimeter, the Goldmann perimeter and the Maddox tangent scale (MTS). In 13 patients, cyclodeviation in primary position, up-, and downgaze was measured with the above-mentioned devices. The mean differences ranged from 0.3º to 3.1º and were smallest between the HTS and the cycloforometer (89% of all measurements within 2º difference). Measurement of abduction, adduction, elevation, an…
Semi-automated retinal vessel analysis in nonmydriatic fundus photography.
2013
Purpose Funduscopic assessment of the retinal vessels may be used to assess the health status of microcirculation and as a component in the evaluation of cardiovascular risk factors. Typically, the evaluation is restricted to morphological appreciation without strict quantification. Our purpose was to develop and validate a software tool for semi-automated quantitative analysis of retinal vasculature in nonmydriatic fundus photography. Methods matlab software was used to develop a semi-automated image recognition and analysis tool for the determination of the arterial–venous (A/V) ratio in the central vessel equivalent on 45° digital fundus photographs. Validity and reproducibility of the r…
Comparison of partial coherence interferometry and ultrasound for anterior segment biometry.
2008
To assess the performance of a partial coherence interferometry (PCI)-based device for the determination of anterior segment biometry.Clinica Centrofama, Cartagena, Murcia, Spain.Central corneal thickness (CCT), anterior chamber depth (ACD), and lens thickness (LT) were measured with the ACMaster PCI anterior segment biometer and an Echoscan US-1800 ultrasound (US) biometer/pachymeter with and without cycloplegia. To determine the precision of the instruments, the same examiner took 30 consecutive CCT, ACD, and LT measurements in a single subject under the same conditions and with and without cycloplegia. The same measurements were performed in additional subjects.Twenty-one eyes (16 subjec…
Fixation pattern analysis with microperimetry in nystagmus patients
2015
Objective: To assess the usefulness of microperimetry (MP) as an additional objective method for characterizing the fixation pattern in nystagmus. Design: Prospective study. Participants: Fifteen eyes of 8 subjects (age, 12–80 years) with nystagmus from the Lluís Alcanyís Foundation (University of Valencia, Spain) were included. Methods: All patients had a comprehensive ophthalmologic examination including a microperimetric examination (MAIA, CenterVue, Padova, Italy). The following microperimetric parameters were evaluated: average threshold (AT), macular integrity index (MI), fixating points within a circle of 1° (P1) and 2° of radius (P2), bivariate contour ellipse area (BCEA) considerin…
Monocular versus binocular pupillometry.
2004
Purpose To quantify differences between monocular and binocular pupil size measurement under scotopic and mesopic conditions. Setting Department of Ophthalmology, Johannes Gutenberg-University, and Department of Medical Biometry, Epidemiology and Informatics, University of Mainz, Mainz, Germany. Methods Computerized dynamic pupillometry (P2000 SA, Procyon Instruments Ltd.) was used at 3 illumination levels: scotopic at 0.03 lux, mesopic low at 0.82 lux, and mesopic high at 6.4 lux. One hundred forty eyes of 70 healthy volunteers without ocular pathology were examined. The subjects were divided into 2 groups. In the first group, the pupil diameter was measured binocularly first. In the secon…
The ocular manifestations in IBD screening (OMIS) questionnaire: pilot study on detection of ocular involvement in inflammatory bowel diseases.
2020
Purpose: To assess the usefulness of a dedicated questionnaire for patients with inflammatory bowel diseases (IBD) treated with biological drugs for the detection of ocular extraintestinal manifestations (EIMs). IBD can cause extraintestinal symptoms including ocular complaints which are frequently ignored and may be associated with significant morbidity, including blindness. Methods: We developed a questionnaire, named Ocular Manifestations in IBD Screening (OMIS) questionnaire, after agreement between gastroenterologists and ophthalmologists. The questionnaire was administered by a non-ophthalmologist physician to 96 IBD patients treated with biological drugs. Results: 35 patients (36.5%)…