Search results for "optical coherence"
showing 10 items of 223 documents
Could structural changes in the retinal layers be a new biomarker of mental disorders? A systematic review and thematic synthesis.
2019
It has recently been suggested that alterations of the layers of the retina could be a biomarker of specific mental disorders since they originate in the same embryonic layer as the brain and both are interconnected through the optic nerve. The purpose of this article is to offer a systematic review of the literature and a thematic synthesis on the current state of the alterations of the retina layers identified by optical coherence tomography in patients with schizophrenia, bipolar disorder and major depression. For this purpose, we performed a bibliographic search, a systematic review of the studies and a thematic synthesis of the reported findings. Patients with schizophrenia have more a…
Enhanced Oxidative Stress and Other Potential Biomarkers for Retinopathy in Type 2 Diabetics: Beneficial Effects of the Nutraceutic Supplements
2015
We have studied the global risk of retinopathy in a Mediterranean population of type 2 diabetes mellitus (T2DM) patients, according to clinical, biochemical, and lifestyle biomarkers. The effects of the oral supplementation containing antioxidants/omega 3 fatty acids (A/ω3) were also evaluated. Suitable participants were distributed into two main groups: (1) T2DMG (with retinopathy (+DR) or without retinopathy (−DR)) and (2) controls (CG). Participants were randomly assigned (+A/ω3) or not (−A/ω3) to the oral supplementation with a daily pill of Nutrof Omega (R) for 18 months. Data collected including demographics, anthropometrics, characteristics/lifestyle, ophthalmic examination (best cor…
Large platelets but not putative endothelial progenitor cells are associated with low strut coverage after drug-eluting stent implantation
2015
Objectives This study assessed whether different subsets of circulating endothelial and putative endothelial progenitor cells (CEC and EPC) correlate with stent strut coverage (SSC) using second generation optical coherence tomography (OCT). Background Due to the lack of imaging modalities with a resolution down to the magnitude of a few cells, the influence of EPC on endothelialisation of drug-eluting stents has not been assessed in patients. Methods In 37 patients, SSC of everolimus-eluting stents was assessed by OCT 5-7months after stent implantation. Different subsets of EPC (CD34(+)KDR(+), CD34(+)KDR(+)CD45(dim), CD133(+), CD3(+)CD31(+)), CEC (CD31(+)CD45(-)CD146(+)), and CD31(+)CD45(-…
Site-Coded Oral Squamous Cell Carcinoma Evaluation by Optical Coherence Tomography (OCT): A Descriptive Pilot Study
2022
Optical Coherence Tomography (OCT) is an emerging non-invasive method for oral diagnostics, proving to be a practicable device for epithelial and subepithelial evaluation. The potential validity of OCT in oral cancer assessment has been explored but, to date, there are very few investigations conducted with a systematic comparison between clinical/histological and OCT parameters, especially in strict reference to the anatomical site-codification of the oral mucosa. In this regard, our study performed a two-steps evaluation (in vivo OCT and histological investigations) of suspected OSCCs, progressively recruited, using as references the OCT images of the same site-coded healthy mucosa, to pr…
Response by Meneveau and Ecarnot to Letter Regarding Article, “Optical Coherence Tomography to Optimize Results of Percutaneous Coronary Intervention…
2017
We read with interest the letters by Vallurupalli and Uretsky and also Dr Nadir relating to the results of the DOCTORS study (Does Optical Coherence Tomography Optimize Results of Stenting).1 We thank the authors for their insightful remarks. Vallurupalli and Uretsky raise an interesting point when they underline that a prolonged inflation time is superior to a rapid inflation/deflation technique in terms of both stent expansion and apposition. We acknowledge that we did not take stent inflation time into account in the case report form of the DOCTORS study. The arguments put forward by Vallurupalli and Uretsky suggest that this variable should be systematically recorded and reported. Howev…
New imaging techniques and opportunities in endoscopy.
2011
Gastrointestinal endoscopy is undergoing major improvements, which are driven by new available technologies and substantial refinements of optical features. In this Review, we summarize available and evolving imaging technologies that could influence the clinical algorithm of endoscopic diagnosis. Detection, characterization and confirmation are essential steps required for proper endoscopic diagnosis. Optical and nonoptical methods can help to improve each step; these improvements are likely to increase the detection rate of neoplasias and reduce unnecessary endoscopic treatments. Furthermore, functional and molecular imaging are emerging as new diagnostic tools that could provide an oppor…
In Vitro Measurement of Strain Localization Preceding Dissection of the Aortic Wall Subjected to Radial Tension
2020
AbstractBackgroundAortic dissection (AD) is a common pathology and challenging clinical problem. A better understanding of the biomechanical effects preceding its initiation is essential for predicting adverse events on a patient-specific basis. Moreover, the predictability of patient-specific biomechanics-based computational models is hampered by uncertainty about boundary conditions and material properties.ObjectivePredisposition of thoracic aortic aneurysms (TAA) to ADs can be related to the degradation of biomechanically important constituents in the aortic wall of TAAs. The goal of the present study is to develop a new methodology to measure strain fields in aortic tissues subjected to…
Intraoperative dexamethasone intravitreal implant in diabetic macular edema patients undergoing phacoemulsification: The CataDex study
2021
Purpose To assess the impact of preoperative intravitreal dexamethasone implant (DexI) on functional and anatomic outcomes in patients with diabetic macular edema (DME) who underwent phacoemulsification cataract surgery. Methods Prospective and non-comparative study conducted on consecutive DME patients undergoing cataract surgery. DexI was administered 15 days before surgery and in a pro re nata regime after surgery. Main outcome measures were mean change in central retinal thickness (CRT), central subfield thickness (CST), total macular volume (TMV), and central subfield volume (CSV) from baseline to month-12. Secondary outcome was mean change in best corrected visual acuity (BCVA). Resul…
The Usefulness of Optical Coherence Tomography in Disease Progression Monitoring in Younger Patients with Relapsing-Remitting Multiple Sclerosis: A S…
2022
The purpose of the study was to assess the usefulness of optical coherence tomography (OCT) in the detection of the neurodegenerative process in younger patients with multiple sclerosis (MS). The study group consisted of 61 patients with a relapsing remitting course of MS (mean age 36.4 ± 6.7 years) divided into two groups: short (≤5 years) and long (>10 years) disease duration. OCT, P300 evoked potential, Montreal Cognitive Assessment, and performance subtests (Picture Completion and Digit Symbol) of the Wechsler Adult Intelligence Scale were performed in all patients. Mean values of most parameters assessed in OCT (pRNFL Total, pRNFL Inferior, pRNFL Superior, pRNFL Temporalis, mRNFL, G…
Infracyanine Green vs. Brilliant Blue G in Inverted Flap Surgery for Large Macular Holes: A Long-Term Swept-Source OCT Analysis
2020
Background and Objectives: To compare the long-term toxicity of infracyanine green (IFCG) to brilliant blue G (BBG) in inverted internal limiting membrane flap surgery (I-ILMFS) for large, full-thickness macular holes (FTMHs). Materials and Methods: Prospective randomized study including 39 eyes with &ge