Management of a patient with multiple device replacements and extractions: When the leadless pacemaker is a viable solution
2022
Leadless pacemaker (LPs) is a safe device and the implantation rates of this device is increasing. The device extraction and replacement are today a challenging procedures especially in case of infections, fragile and older patients or in unfavorable venous anatomy; LPs can be a valid alternative strategy in these cases. We report a case of management of a patient with multiple previous device replacements and extractions, with malfunction of transvenous pacemaker and with a fibrous membrane between the walls of the ventricular lead and the superior vena cava (SVC), who underwent a successful LP implantation.
Jugular pacing lead extraction with laser sheath: a case report.
2010
Over the past 20 years, the number of patients with pacemakers (PM) or implantable cardioverter defibrillators has risen markedly; consequently, an increasing number of lead-removal procedures have become necessary. A 64-year-old woman presenting with an infected device pocket and positive bacterial cultures ( Staphylococcus aureus ) was admitted to our department for lead removal; in 1991, she underwent VVI PM implantation for atrioventricular II degree Mobitz 1 block, and a unipolar lead was introduced via the left jugular vein. The procedure was performed in our Electrophysiology Lab with a cardiac surgeon on standby, using an excimer laser system emitting the energy at the tip of a flex…
Role of cardiac dyssynchrony and resynchronization therapy in functional mitral regurgitation
2016
Functional mitral regurgitation (FMR) is a common complication of left ventricle (LV) dysfunction and remodelling. Recently, it has been recognized as an independent prognostic factor in both ischaemic and non-ischaemic LV dysfunctions. In this review article, we discuss the mechanisms through which cardiac dyssynchrony is involved in FMR pathophysiologic cascade and how cardiac resynchronization therapy (CRT) can have therapeutic effects on FMR by reverting specific dyssynchrony pathways. We analyse recent clinical trials focusing on CRT impact on FMR in 'real-world' patients, the limits and future perspectives that could eventually generate new predictors of CRT response in terms of FMR r…
Focus on right ventricular outflow tract septal pacing
2013
SummaryExperimental and clinical studies have shown that right ventricular apical pacing may result in long-term deleterious effects on account of its negative impact on left ventricular remodeling through desynchronization. This risk appears more pronounced in patients with even moderate left ventricular dysfunction and generally occurs after at least 1 year of pacing. As right ventricular apical pacing may be associated with the development of organic mitral insufficiency, other sites that allow for more physiological stimulation, such as right ventricular outflow tract septal pacing, have been developed, with good feasibility and reproducibility. However, the prospective randomized studi…
Leadless pacemaker implant in patients requiring CIED extraction: outcomes based upon timing of extraction
2021
Abstract Background Previous results from global Micra Transcatheter Pacemaker clinical trials have demonstrated leadless pacing as a safe and attractive option for patients with prior cardiac implantable electronic device (CIED) infection and extraction. Whether outcomes differ based upon the timing of prior device extraction has not been studied. Purpose To describe characteristics and outcomes of patients undergoing CIED extraction during or prior to Micra implantation. Methods Patients who underwent CIED explant and Micra implantation were identified from the Micra Post-Approval Registry and Micra Acute Performance studies. Baseline characteristics were summarized. A Fine-Gray competing…
Cardiovascular outcomes after cardiac resynchronization therapy in cardiac amyloidosis
2021
Abstract Aims Cardiac resynchronization therapy (CRT) is highly effective in dilated cardiomyopathy (DCM) patients with impaired left ventricular ejection fraction (LVEF) and left bundle block branch. In cardiac amyloidosis (CA) patients, left ventricular dysfunction and conduction defects are common, but the potential of CRT to improve cardiac remodelling and survival in this particular setting remains undefined. We investigated cardiovascular outcomes in CA patients after CRT implantation in terms of CRT echocardiographic response and major cardiovascular events (MACEs). Methods and results Our retrospective study included 47 CA patients implanted with CRT devices from January 2012 to Feb…
Cardiac pacemaker function of HCN4 channels in mice is confined to embryonic development and requires cyclic AMP.
2008
Important targets for cAMP signalling in the heart are hyperpolarization-activated and cyclic nucleotide-gated (HCN) channels that underlie the depolarizing 'pacemaker' current, I(f). We studied the role of I(f) in mice, in which binding of cAMP to HCN4 channels was abolished by a single amino-acid exchange (R669Q). Homozygous HCN4(R669Q/R669Q) mice die during embryonic development. Prior to E12, homozygous and heterozygous embryos display reduced heart rates and show no or attenuated responses to catecholaminergic stimulation. Adult heterozygous mice display normal heart rates at rest and during exercise. However, following beta-adrenergic stimulation, hearts exhibit pauses and sino-atrial…