Search results for "parametric"

showing 10 items of 980 documents

Noninvasive assessment of baroreflex sensitivity in post-MI patients by an open loop parametric model of RR-systolic pressure interactions

2003

Noninvasive evaluation of baroreflex sensitivity is considered an important goal for diagnosis and prognosis in post-MI patients. Methodological approach and physiological measure conditions may be the main causes for the differences found with respect to the standard Phenylephrine test. In this study, three linear parametric models, describing variability and mutual interactions of RR interval and systolic arterial pressure (SAP), were compared in relation to their ability to quantify baroreflex gain, using the Phenylephrine test index (Phe/sub BRS/) as reference. By monovariate autoregressive (AR) model, bivariate AR model and open loop ARXAR model, specific gain indexes (/spl alpha//sub …

medicine.medical_specialtyAlpha (ethology)HemodynamicsRegression analysisBaroreflexCorrelationBlood pressureAutoregressive modelInternal medicineSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaParametric modelmedicineCardiologyCardiology and Cardiovascular MedicineSoftwareMathematicsComputers in Cardiology 1999. Vol.26 (Cat. No.99CH37004)
researchProduct

Effects of a short-term resistance program using elastic bands versus weight machines for sedentary middle-aged women.

2008

This study was designed to determine whether different effects on functional capacity and body composition were produced by using different devices (elastic bands (EBs) versus weight machines (WMs)) with the same resistance training program. Forty-five healthy sedentary middle-aged women volunteers were chosen and randomly assigned to 1 of 3 groups: 21 subjects trained using EBs (EBG), 14 in trained using WMs (WMG), and 10 were controls (CG). Both exercise groups trained with a periodized muscular endurance program twice a week for 10 weeks, with a total of 6 exercises per session for the major muscle groups. Exercise intensity was equalized by jointly monitoring the same targeted number of…

medicine.medical_specialtyAnalysis of VarianceWeight Liftingbusiness.industryStrength trainingPhysical Therapy Sports Therapy and RehabilitationSquatResistance TrainingGeneral MedicineMiddle AgedAdaptation PhysiologicalStatistics NonparametricIntensity (physics)Exercise intensityPhysical therapyBody CompositionMedicineHumansOrthopedics and Sports MedicineFemaleAnalysis of varianceEarly phaseLead (electronics)businessBioelectrical impedance analysisJournal of strength and conditioning research
researchProduct

Three-dimensional parametric modeling of bicuspid aortopathy and comparison with computational flow predictions

2017

Bicuspid aortic valve (BAV)-associated ascending aneurysmal aortopathy (namely "bicuspid aortopathy") is a heterogeneous disease making surgeon predictions particularly challenging. Computational flow analysis can be used to evaluate the BAV-related hemodynamic disturbances, which likely lead to aneurysm enlargement and progression. However, the anatomic reconstruction process is time consuming so that predicting hemodynamic and structural evolution by computational modeling is unfeasible in routine clinical practice. The aim of the study was to design and develop a parametric program for three-dimensional (3D) representations of aneurysmal aorta and different BAV phenotypes starting from s…

medicine.medical_specialtyComputer science0206 medical engineeringBiomedical EngineeringMedicine (miscellaneous)Bioengineering02 engineering and technology030204 cardiovascular system & hematologyBiomaterials03 medical and health sciences0302 clinical medicineBicuspid aortic valveAneurysmInternal medicinemedicineRoutine clinical practicecardiovascular diseasesParametric statisticsGeneral Medicinemedicine.disease020601 biomedical engineeringStructural evolutionFlow (mathematics)Parametric modelcardiovascular systemCardiologyAlgorithmArtificial Organs
researchProduct

Single snapshot RGB multispectral imaging at fixed wavelengths: proof of concept

2014

A concept of single snapshot multispectral imaging by standard RGB image sensors under spectrally-specific illumination comprising a fixed number of narrow spectral lines is discussed and experimentally validated. The limiting conditions, RGB band spectral crosstalk corrections and potential applications for parametric mapping of skin are regarded, along with the preliminary results of the proof-of-concept measurements.

medicine.medical_specialtyComputer sciencebusiness.industryMultispectral imageSpectral lineSpectral imagingWavelengthOpticsProof of conceptComputer Science::Computer Vision and Pattern RecognitionmedicineRGB color modelSnapshot (computer storage)businessParametric statisticsSPIE Proceedings
researchProduct

Telaprevir drug monitoring during antiviral therapy of hepatitis C graft infection after liver transplantation

2014

Background & Aims Recurrence of hepatitis C virus (HCV) infection after orthotopical liver transplantation (OLT) is common and associated with reduced graft and patient survival. The protease inhibitor telaprevir may enhance virological response rates in patients after OLT in combination with pegylated interferon-alfa and ribavirin. Pharmacokinetic studies have shown significant drug–drug interactions between telaprevir and immunosuppression (IS), but telaprevir pharmacokinetics in OLT patients with IS are unknown. Aim of the present study was to analyse telaprevir plasma concentrations in patients with HCV genotype 1 infection after OLT in comparison to patients without OLT and IS. Methods…

medicine.medical_specialtyHepatitis C virusmedicine.medical_treatmentPharmacologyLiver transplantationmedicine.disease_causeAntiviral AgentsGastroenterologyStatistics NonparametricTacrolimusPolyethylene GlycolsTelaprevirchemistry.chemical_compoundRecurrenceTandem Mass SpectrometryInternal medicineRibavirinmedicineHumansProspective StudiesImmunosuppression TherapyHepatologybusiness.industryRibavirinInterferon-alphaHepatitis Cmedicine.diseaseHepatitis CRecombinant ProteinsTacrolimusLiver TransplantationTransplantationsurgical procedures operativechemistryDrug Therapy CombinationDrug MonitoringbusinessViral hepatitisOligopeptidesChromatography Liquidmedicine.drugLiver International
researchProduct

Canal transportation caused by a new instrumentation technique and three standard techniques

1996

The ability of three different enlarging techniques (balanced force concept, step-back, and recapitulation) and a prototype system to maintain the original canal path during root canal preparation were compared, in vitro, with a theoretical ideally prepared root canal. Measurements were made at the concave and convex sides of the canal at four different levels (1, 4, 5, and 7 mm from apical, respectively). Simulated root canals embedded in clear casting resin and an enlarging computer-supported device were used for this study. The results showed that none of the enlarging techniques used in this study was able to prepare a canal ideally. The prototype system, at level 1, showed an ideal amo…

medicine.medical_specialtyInstrumentationRoot canalConvex sideConcave sideStatistics NonparametricSurgeryModels Structuralmedicine.anatomical_structureEvaluation Studies as TopicSmear Layerotorhinolaryngologic diseasesmedicinesense organsGeneral DentistryRoot Canal PreparationBiomedical engineeringMathematicsJournal of Endodontics
researchProduct

Intra-operative locally injected pharmacotherapy as a novel strategy for adhesion prophylaxis.

2012

Abstract Background Pharmacotherapy for peritoneal adhesion prophylaxis has been a focus for intensive research. Previous strategies included intravenous and intraperitoneal application of suitable pharmaceutical agents. However, success of these strategies in humans has been limited. Here we describe intra-operative local injection of pharmaceuticals as a novel strategy for adhesion prophylaxis. Methods N  = 208 peritoneal lesions were created in 26 adult Wistar rats. In each animal, lesions on one flank were randomly chosen for treatment with locally injected prednisolone whereas the contralateral side was injected with normal saline. Half of the animals were randomly selected for early a…

medicine.medical_specialtyIntra operativeAdhesionsmedicine.medical_treatmentPrednisoloneAnti-Inflammatory AgentsAdhesion (medicine)Tissue AdhesionsPeritoneal DiseasesStatistics NonparametricRandom AllocationPharmacotherapyLocal injectionStatistical significanceAbdomenmedicineAnimalsLocal anesthesiaRats WistarSteroidSalineIntraoperative Carebusiness.industryHistocytochemistryGeneral Medicinemedicine.diseaseSurgeryRatsDisease Models AnimalPrednisoloneSurgeryPeritoneumbusinessLocal injectionInjections Intraperitonealmedicine.drugInternational journal of surgery (London, England)
researchProduct

Multiparametric MRI and Radiomics in Prostate Cancer: A Review of the Current Literature

2021

Prostate cancer (PCa) represents the fourth most common cancer and the fifth leading cause of cancer death of men worldwide. Multiparametric MRI (mp-MRI) has high sensitivity and specificity in the detection of PCa, and it is currently the most widely used imaging technique for tumor localization and cancer staging. mp-MRI plays a key role in risk stratification of naïve patients, in active surveillance for low-risk patients, and in monitoring recurrence after definitive therapy. Radiomics is an emerging and promising tool which allows a quantitative tumor evaluation from radiological images via conversion of digital images into mineable high-dimensional data. The purpose of radiomics is to…

medicine.medical_specialtyMedicine (General)Clinical BiochemistryReviewProstate cancerR5-920RadiomicsProstatemedicinemagnetic resonance imagingcancerGleason scoreCancer stagingPI-RADSprostatemedicine.diagnostic_testbusiness.industryCancerMultiparametric MRIMagnetic resonance imagingmedicine.diseasePI-RADSmedicine.anatomical_structureradiomicsRadiologybusinessSettore MED/36 - Diagnostica Per Immagini E RadioterapiaDiagnostics
researchProduct

Causal linear parametric model for baroreflex gain assessment in patients with recent myocardial infarction

2001

Spectral and cross-spectral analysis of R-R interval and systolic arterial pressure (SAP) spontaneous fluctuations have been proposed for noninvasive evaluation of baroreflex sensitivity (BRS). However, results are not in good agreement with clinical measurements. In this study, a bivariate parametric autoregressive model with exogenous input (ARXAR model), able to divide the R-R variability into SAP-related and -unrelated parts, was used to quantify the gain (αARXAR) of the baroreflex regulatory mechanism. For performance assessing, two traditional noninvasive methods based on frequency domain analysis [spectral, baroreflex gain by autogressive model (αAR); cross-spectral, baroreflex gain…

medicine.medical_specialtyPhysiologySystoleEntropyRR intervalMyocardial InfarctionHemodynamicsBlood PressureBaroreflexAutoregressive modelSpectral analysiElectrocardiographyPhenylephrineHeart RateInternal medicinePhysiology (medical)MedicineHumansVasoconstrictor AgentsIn patientAnalysis of VarianceModels Statisticalbusiness.industryModels CardiovascularBaroreflexMiddle AgedR-R-SAP transfer functionSurgeryBlood pressureBaroreflex sensitivityParametric modelCardiologySystolic arterial pressureRegression AnalysisCardiology and Cardiovascular MedicinebusinessRecent myocardial infarction
researchProduct

Interobserver discrepancy in liver fibrosis using transient elastography

2012

Summary.  Transient elastography is a useful method to assess liver fibrosis, but uncertainties still exist regarding reliability and reproducibility of the technique. We aimed to improve knowledge on interobserver variability with the procedure and tried to find factors associated with such variability. This was a cross-sectional study to compare the results of transient elastography performed by two different operators, one test made just after the other. We assessed both results with correlation tests and with repeated parametric or nonparametric tests, as needed. We also carried out a multivariate analysis to find factors associated with discrepancy in the results obtained by the two op…

medicine.medical_specialtyReproducibilityMultivariate analysisHepatologybusiness.industryLiver fibrosisNonparametric statisticsStandard deviationCorrelationInfectious DiseasesInterquartile rangeVirologymedicineRadiologybusinessTransient elastographyJournal of Viral Hepatitis
researchProduct