Search results for "particle detector"

showing 10 items of 200 documents

The GREAT spectrometer

2003

Abstract The GREAT spectrometer is designed to measure the decay properties of reaction products transported to the focal plane of a recoil separator. GREAT comprises a system of silicon, germanium and gas detectors optimised for detecting the arrival of the reaction products and correlating with any subsequent radioactive decay involving the emission of protons, α particles, β particles, γ rays, X-rays or conversion electrons. GREAT can either be employed as a sensitive stand-alone device for decay measurements at the focal plane, or used to provide a selective tag for prompt conversion electrons or γ rays measured with arrays of detectors deployed at the target position. A new concept of …

PhysicsNuclear and High Energy PhysicsSpectrometerPhysics::Instrumentation and Detectorsbusiness.industryAlpha particleDead timeCharged particleParticle detectorSemiconductor detectorNuclear physicsOpticsBeta particlebusinessInstrumentationRadioactive decayNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Electron-TOF-analyser for complete momentum analysis in photoemission from surfaces

2001

Abstract We present a new method for momentum-selective imaging by means of a time-of-flight (TOF) technique. The instrument employs a time- and space-resolving delayline detector in combination with a parabolic electrostatic field and a drift space. We use this kind of spectrometer, to raise the efficiency of experiments, which are total momentum resolved. The main difference to conventional photoemission experiments using a rotatable spectrometer is the simultaneous detection of all emitted photoelectrons. In addition to this feature, the angular distribution should be directly visible, to observe solid state symmetries. In order to facilitate these requirements, we use a delayline detect…

PhysicsNuclear and High Energy PhysicsSpectrometerPhysics::Instrumentation and Detectorsbusiness.industryAnalyserDetectorPhotoelectric effectParticle detectorMomentumTime of flightOpticsMeasuring instrumentbusinessInstrumentation
researchProduct

Performance enhancements of compound semiconductor radiation detectors using digital pulse processing techniques

2011

Abstract The potential benefits of using compound semiconductors for X-ray and gamma ray spectroscopy are already well known. Radiation detectors based on high atomic number and wide band gap compound semiconductors show high detection efficiency and good spectroscopic performance even at room temperature. Despite these appealing properties, incomplete charge collection is a critical issue. Generally, incomplete charge collection, mainly due to the poor transport properties of the holes, produces energy resolution worsening and the well known hole tailing in the measured spectra. In this work, we present a digital pulse processing (DPP) system for high resolution spectroscopy with compound …

PhysicsNuclear and High Energy PhysicsSpectrometerPreamplifierbusiness.industryDetectorSettore FIS/01 - Fisica SperimentaleCompound semiconductors CdTe detectors X-ray and gamma ray spectroscopy Digital pulse processing Pulse height analysis Pulse shape analysisParticle detectorPulse (physics)OpticsGamma spectroscopySpectroscopybusinessInstrumentationShape analysis (digital geometry)
researchProduct

Performance of long modules of silicon microstrip detectors

1998

This note describes the performance of modules assembled with up to twelve silicon microstrip detectors. These modules were built for the instrumented Silicon Target (STAR) that has been installed in the NOMAD spectrometer. Laboratory and test beam results are compared with model predictions. For a module of nine detectors, test beam results indicate a signal--to--noise ratio of 19, a hit finding efficiency of 99.8\% and a spatial resolution of 6.0 $\mu$m. Laboratory measurements indicate that modules of twelve detectors exhibit a signal--to--noise ratio of the order of 16.

PhysicsNuclear and High Energy PhysicsSpectrometerSiliconbusiness.industryPhysics::Instrumentation and DetectorsDetectorchemistry.chemical_elementFísicaParticle detectorSemiconductor detectorNuclear physicssilicon microstrip detectors; neutrino oscillationsSignal-to-noise ratioOpticschemistryMeasuring instrumentHigh Energy Physics::ExperimentDetectors and Experimental TechniquesbusinessInstrumentationImage resolution
researchProduct

The large-area micro-channel plate entrance detector of the heavy-ion magnetic spectrometer PRISMA

2005

This paper describes the entrance detector of the magnetic spectrometer PRISMA recently installed at Legnaro. The detector is based on rectangular (80 x 100 mm(2)) Micro-Channel Plates (MCP). It provides a fast time signal and its position-sensitive anode allows to extract the X and Y information. It exploits an electrostatic field for the acceleration of secondary electrons from a thin Carbon foil (similar or equal to 20 mu g/cm(2)) onto the MCP assembly. The electrons are guided by a parallel magnetic field. Good performances were obtained in the laboratory tests. The detector is presently installed at the entrance of PRISMA and gives resolutions <= 400 ps in time, and 1 mm in both X and …

PhysicsNuclear and High Energy PhysicsSpectrometerbusiness.industryDetectordetectors for heavy ions ; micro-channel plates ; magnetic spectrometers ; low-energy heavy-ion reactionsParticle detectorSecondary electronsCharged particleMagnetic fieldNuclear physicsOpticsElectric fieldMicrochannel plate detectorbusinessInstrumentation
researchProduct

PERFORMANCE OF THE ALEPH TIME PROJECTION CHAMBER

1991

The performance of the ALEPH Time Projection Chamber (TPC) has been studied using data taken during the LEP running periods in 1989 and 1990. After correction of residual distortions and optimisation of coordinate reconstruction algorithms, single coordinate resolutions of 173-mu-m in the azimuthal and 740-mu-m in the longitudinal direction are achieved. This results in a momentum resolution for the TPC of DELTA-p/p2 = 1.2 x 10(-3) (GeV/c)-1. In combination with the ALEPH Inner Tracking Chamber (ITC), a total momentum resolution of DELTA-p/p2 = 0.8 x 10(-3) (GeV/c)-1 is obtained. With respect to particle identification, the detector achieves a resolution of 4.4% for the measurement of the i…

PhysicsNuclear and High Energy PhysicsTime projection chamberPhysics::Instrumentation and DetectorsTracking (particle physics)Particle identificationParticle detectorMomentumNuclear physicsAzimuthPair productionHigh Energy Physics::ExperimentDetectors and Experimental TechniquesInstrumentationImage resolution
researchProduct

The optical/UV filters for the EPIC experiment

1998

EPIC, the European Photon Imaging Cameras is an experiment based on cooled CCDs on board the ESA X-ray Multi Mirrors satellite due to be launched in 1999. Since CCD's are sensitive to radiation other than X-rays, namely Optical and UV light, filters are necessary to prevent this radiation from reaching the detector sensitive area. Three types of filters were developed, to be used alternatively depending on target source. Here we report on the medium and thin filters developed by MOXTEK Inc. in Orem, Utah, while the thick ones, developed at the Max-Planck-Institut fur Extraterrestrische Physik (MPE, Germany) have been described elsewhere. The two filters, described here, have a 1600 /spl Ari…

PhysicsNuclear and High Energy PhysicsX-ray astronomyPhotonbusiness.industryDetectorRadiationParticle detectorSettore FIS/05 - Astronomia E AstrofisicaOpticsNuclear Energy and EngineeringFilter (video)CalibrationOptoelectronicsElectrical and Electronic EngineeringbusinessOptical filterIEEE Transactions on Nuclear Science
researchProduct

Surface processing of TlBr single crystals used for radiation detectors

2009

Abstract The processing method for obtaining the high-quality surfaces of TlBr single crystals, providing removal of a mechanically destroyed surface layer by chemical etching, is developed. The crystals grown from the melt of purified materials by the Bridgman–Stockbarger method were used for the experiments. The Vickers microhardness as a structure-sensitive technique was used in a study of the crystal quality and properties of the plastically deformed surface layer created by cutting. It was shown that even under highly accurate conditions of cutting, the depth of the work-hardened surface layer with a high density of dislocations, vacancies and other structural defects exceeds 20 μm. Th…

PhysicsNuclear and High Energy Physicsbusiness.industryDetectorSurface processingIsotropic etchingIndentation hardnessParticle detectorCrystalOptoelectronicsSurface layerLuminescencebusinessInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Pulse shape analysis of liquid scintillators for neutron studies

2002

The acquisition of signals from liquid scintillators with Flash ADC of high sampling rate ð 1G S=sÞ has been investigated. The possibility to record the signal waveform is of great advantage in studies with g’s and neutrons in a high count-rate environment, as it allows to easily identify and separate pile-up events. The shapes of pulses produced by g-rays and neutrons have been studied for two different liquid scintillators, NE213 and C6D6: A 1-parameter fitting procedure is proposed, which allows to extract information on the particle type and energy. The performance of this method in terms of energy resolution and n=g discrimination is analyzed, together with the capability to identify a…

PhysicsNuclear and High Energy Physicsbusiness.industryFlash ADCScintillatorSignalParticle detectorNuclear magnetic resonanceOpticsWaveformNeutron detectionNeutronbusinessInstrumentationEnergy (signal processing)Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

A portable telescope based on the ALIBAVA system for test beam studies

2013

Abstract A test beam telescope has been built using the ALIBAVA system to drive its data acquisition. The basic telescope planes consist of four XYT stations. Each station is built from a detector board with two strip sensors, mounted one in each side (strips crossing at 90°). The ensemble is coupled to an ALIBAVA daughter board. These stations act as reference frame and allow a precise track reconstruction. The system is triggered by the coincidence signal of the two scintillators located up and down stream. The telescope can hold several devices under tests. Each ALIBAVA daughter board is linked to its corresponding mother board. The system can hold up to 16 mother boards. A master board …

PhysicsNuclear and High Energy Physicsbusiness.industryTrack (disk drive)DetectorTracking (particle physics)SignalParticle detectorlaw.inventionTelescopeData acquisitionlawMeasuring instrumentbusinessInstrumentationComputer hardwareNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct