Search results for "pattern"
showing 10 items of 4203 documents
MORPHOMETRIC ANALYSIS OF HUMAN CORNEAL ENDOTHELIUM BY MEANS OF SPATIAL POINT PATTERNS
2002
This paper presents a method for detecting abnormalities in spatial arrangements of cells within any tissue that can be described by different sets of relevant points. The method has been applied to the detection of subtle abnormalities in corneal endothelia. Images of this type of tissue can be characterized by two types of points: cell centroids and triple points associated with the apical intersections as it was proposed by Díaz.7 Both types of points jointly considered are modeled using a bivariate spatial point process; then a statistical analysis based on certain distributional descriptors proposed by Doguwa4,9 is carried out to discriminate severe and subtle abnormalities from contr…
A granulometric analysis of specular microscopy images of human corneal endothelia
2005
The inner layer of the human cornea, called the corneal endothelium, plays an important role in the maintenance of corneal transparency. Specular microscopy is the most widely used technique to study the corneal endothelium in vivo. Improvements in technology have allowed us to obtain good quality specular images, but the detection and quantification of small size-shape cell changes is not obvious, specially when the physician wants to evaluate endothelial cell changes after some surgical procedures. This paper proposes a methodology to analyze specular microscopy images. Every corneal endothelium is described by means of different cumulative distribution functions or some moments (mean, st…
Classifying human endothelial cells based on individual granulometric size distributions
2002
Abstract This paper presents an application to a medical problem of methods of shape analysis based on mathematical morphology. The medical problem consists on the detection of abnormalities in the corneal endothelium, a tissue composed by quasi-planar cells of ideally regular hexagonal shape. Images of this tissue are taken by a specular microscope and used to evaluate the corneal endothelium status. Up to now, cell density, hexagonality and an analysis of cell areas are the usual descriptors of a corneal endothelium. These parameters are not sensitive enough to detect subtle lesions. What this paper proposes is an analysis based on granulometries, which are size-shape descriptors widely u…
Set Descriptors for Visual Evaluation of Human Corneal Endothelia
2001
Images of corneal endothelium obtained from specular microscopy are of great importance in the evaluation of the corneal endothelium status. Several commercial tools provide some numerical descriptors to characterize these images in terms of cell density, hexagonality, and some descriptive statistics of the cell areas. However, it is a too simple analysis that only detects severe abnormal endothelia with many irregular and large cells. Detection of subtle abnormalities needs a more refined analysis. This paper proposes a shape-size descriptor based on some modified versions of the geometric covariogram. This descriptor is presented as a valid alternative to the classical analysis that provi…
Unsupervised change detection with kernels
2012
In this paper an unsupervised approach to change detection relying on kernels is introduced. Kernel based clustering is used to partition a selected subset of pixels representing both changed and unchanged areas. Once the optimal clustering is obtained the estimated representatives (centroids) of each group are used to assign the class membership to all others pixels composing the multitemporal scenes. Different approaches of considering the multitemporal information are considered with accent on the computation of the difference image directly in the feature spaces. For this purpose a difference kernel approach is successfully adopted. Finally an effective way to cope with the estimation o…
Learning-automaton-based online discovery and tracking of spatiotemporal event patterns.
2013
Discovering and tracking of spatiotemporal patterns in noisy sequences of events are difficult tasks that have become increasingly pertinent due to recent advances in ubiquitous computing, such as community-based social networking applications. The core activities for applications of this class include the sharing and notification of events, and the importance and usefulness of these functionalities increase as event sharing expands into larger areas of one's life. Ironically, instead of being helpful, an excessive number of event notifications can quickly render the functionality of event sharing to be obtrusive. Indeed, any notification of events that provides redundant information to the…
Lambda+, the renewal of the Lambda Architecture: Category Theory to the rescue
2021
Designing software architectures for Big Data is a complex task that has to take into consideration multiple parameters, such as the expected functionalities, the properties that are untradeable, or the suitable technologies. Patterns are abstractions that guide the design of architectures to reach the requirements. One of the famous patterns is the Lambda Architecture, which proposes real-time computations with correctness and fault-tolerance guarantees. But the Lambda has also been highly criticized, mostly because of its complexity and because the real-time and correctness properties are each effective in a different layer but not in the overall architecture. Furthermore, its use cases a…
Structural modelling and mechanical tests supporting the design of the ATHENA X-IFU thermal filters and WFI optical blocking filter
2018
Copyright 2018 Society of Photo-Optical Instrumentation Engineers (SPIE). One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited. ATHENA is a Large high energy astrophysics space mission selected by ESA in the Cosmic Vision 2015-2025 Science Program. It will be equipped with two interchangeable focal plane detectors: the X-Ray Integral Field Unit (X-IFU) and the Wide Field Imager (WFI). Both detectors require x-ray transparent filters to fully exploit their sensitivity. In order to maximize the X-ray tra…
2016 European Guidelines on cardiovascular disease prevention in clinical practice The Sixth Joint Task Force of the European Society of Cardiology a…
2016
ABI : ankle–brachial (blood pressure) index ABPM : ambulatory blood pressure monitoring ACCORD : Action to Control Cardiovascular Risk in Diabetes ACE-I : angiotensin-converting enzyme inhibitor ACS : acute coronary syndromes ADVANCE : Action in Diabetes and Vascular disease: PreterAx
Tratamiento psicofarmacológico del trastorno bipolar en América Latina
2011
Objective: This study assessed the treatment preferences among Latin-American psychiatrists for their bipolar disorder patients and if these preferences reflect the current guidelines. Methods: We designed a survey comprised of fourteen questions. All the questions were aimed at the treatment of bipolar I patients only. We distributed the survey by hand or e-mail to psychiatrists in eight different countries: Argentina, Brasil, Colombia, Costa Rica, Ecuador, México, Perú and Venezuela. Between May 2008 and June 2009, we were able to gather 1143 surveys. Results: As the initial choice of treatment for a bipolar patient who debuts with mania, 61.3% choose a combination of an atypical antipsyc…