Search results for "pcb"

showing 10 items of 31 documents

Optimization of large-volume injection for the determination of polychlorinated biphenyls in children's fast-food menus by low-resolution mass spectr…

2008

International audience; This study includes the determination of five indicator polychlorinated biphenyls (PCBs) (52, 101, 153, 138, and 180), six non-ortho PCBs (35, 80, 81, 77, 126, and 169), and two mono-ortho PCBs (28 and 118) in fast food for children. A freeze-dried sample of 10 g is extracted by using pressurized n-hexane in two 5 min cycles at 120 degrees C and 100 mbar. Fatty extracts were cleaned up by means of acetonitrile/n-hexane partitioning and gel-permeation chromatography. The fractionation of non-ortho, mono-ortho, and indicator PCBs was made on graphitized carbon solid-phase extraction cartridges by using n-hexane, n-hexane/toluene (99:1, v/v), and toluene as elution solv…

Quality ControlAnalytical chemistryFractionation010501 environmental sciencesTandem mass spectrometryMass spectrometry01 natural sciencesGas Chromatography-Mass SpectrometryMass Spectrometry[CHIM.ANAL]Chemical Sciences/Analytical chemistryTandem Mass SpectrometryHumansPCBs0105 earth and related environmental sciencesDetection limitChromatographyChemistryElution010401 analytical chemistryReproducibility of ResultsGeneral ChemistryRepeatabilityPolychlorinated Biphenyls0104 chemical sciencesChild PreschoolGas chromatographyVaporizerGeneral Agricultural and Biological SciencesFood AnalysisJournal of agricultural and food chemistry
researchProduct

Photochemical sample treatment for extracts clean up in PCB analysis from sediments.

2013

Sample purification can be considered the most polluting step of the whole analytical process for PCBs determination in sediment samples. The use of photochemical sample treatment represents an alternative methodology for extracts clean up allowing for a reduction of the used amount of organic solvents. The first application of a photochemical sample treatment for the selective removal or reduction of organic substances interfering with PCBs analyses in sediments is reported. The method's efficiency and robustness were compared with currently used chromatographic purification. Quality parameters such as recovery, linearity and reproducibility were studied. The entire procedure was validated…

Sample purificationReproducibilityGeologic SedimentsChromatographyPCBChemistryPhotochemistrySample (material)PCB Photochemical sampletreatment Sediment Clean up UV irradiationUV irradiationSedimentReplicatePhotochemistryPolychlorinated BiphenylsGas Chromatography-Mass SpectrometryAnalytical ChemistryClean-upCongenerEnvironmental chemistryClean upSettore CHIM/01 - Chimica AnaliticaSedimentGas chromatography–mass spectrometryPhotochemical sampletreatmentTalanta
researchProduct

Comparison of stable isotope composition and inorganic and organic contaminant levels in wild and farmed bluefin tuna, Thunnus thynnus, in the Medite…

2009

Abstract Stable isotope composition (δ13C and δ15N) and persistent pollutants, including heavy metals (Hg, Cd, Pb, As, Cu, Zn) and organochlorine compounds (PCBs, HCB and p,p′-DDE), were measured in muscle and liver tissues of wild and farmed bluefin tunas to investigate the changes occurring during the farming period and to assess the quality, in terms of contaminants, of the final product. At the end of farming, the food supplied was clearly integrated into the tuna tissues as derived from stable isotope signatures, and, contrarily to the literature findings obtained for other species, farmed tunas showed slight variations in persistent elements and chemical compounds in comparison with w…

Settore BIO/07 - EcologiaEnvironmental EngineeringDichlorodiphenyl DichloroethyleneHealth Toxicology and MutagenesisFish farmingAquaculturechemistry.chemical_compoundAquacultureMetals HeavyPCBs HCB pp’-DDE heavy metals stable isotopes tuna farmingHexachlorobenzeneHydrocarbons ChlorinatedMediterranean SeaAnimalsEnvironmental ChemistryPollutantCarbon IsotopesNitrogen IsotopesbiologyTunabusiness.industryChemistryStable isotope ratioPublic Health Environmental and Occupational Healthfood and beveragesGeneral MedicineGeneral ChemistryHexachlorobenzeneContaminationbiology.organism_classificationPolychlorinated BiphenylsPollutionLiverEnvironmental chemistryMultivariate AnalysisbusinessTunahuman activitiesWater Pollutants ChemicalThunnusEnvironmental MonitoringChemosphere
researchProduct

Performances of a PCB-based Loop Antenna Inductive Sensor for Partial Discharges Detection

2022

This paper presents the test results of an electrically small loop antenna sensor towards detecting the radiated magnetic field due to partial discharge (PD) activities. The loop antenna prototype was printed on an FR-4 substrate with a thickness of 1.6 mm, featuring a compact size of 20 mm times20 mm times1.7 mm. The proposed sensor, initially simulated with Ansys HFSS software, has a resonant frequency of about 100 MHz. Its detection capability for three types of partial discharges (i.e., corona, surface and internal PDs) has been evaluated. Laboratory experiments showed that the evaluated loop spiral antenna is appropriate for the detection of the three types of PDs. Indeed, the results …

Settore ING-IND/31 - ElettrotecnicaHFCT sensorInductive spiral loop; PCB-based sensor; Partial discharge detection; HFCT sensorpartial discharge detectionPCB-based sensorInductive spiral loop
researchProduct

Investigation of PCB-based Inductive Sensors Orientation for Corona Partial Discharge Detection

2022

This paper presents an experimental investigation of two different printed circuit board (PCB) inductive sensors, with meander and non-spiral shapes, to assess their capabilities and best orientation for corona partial discharge (PD) detection. First, simulations with the Ansys HFSS software are performed in order to evaluate the equivalent electrical circuit of the two sensors and their 2d radiation patterns. The meander sensors presented a resonant frequency of 600 MHz, while it was around 1.1 GHz for the non-spiral. The 2d radiation pattern showed that better sensitivity is achieved when the inductive sensor is oriented 90 degrees with respect to the PD source. Experimental tests showed …

Settore ING-IND/31 - ElettrotecnicaInductive looppartial discharge detectionplanar inductorsPCB-based sensorInductive loop; PCB-based sensor; Planar inductors; Partial discharge detection
researchProduct

Polychlorinated Biphenyls in Sediments from Sicilian Coastal Area (Scoglitti) using Automated Soxhlet, GC-MS, and Principal Component Analysis

2014

A methodology for the PAHs and PCBs congener determination in sediment samples has been revised. We determined the distributions of PAHs and PCBs in the superficial sediments of the Scoglitti (Italy) coastal area to provide data for comparison with other marine systems and to hypothesize the sources. Extraction yield, for PCB, was never less than 60% in most cases, while for PAHs, utilizing perdeuterated surrogate standard (benz[a]anthracene-d12 and anthracene-d10) was never less than 72%. The total concentration of the 16 PAHs investigated, expressed as the sum of concentrations, PAHs, varied from 1–5087 μg/kg of dry matrix, while the PCBs ranged from detection limit to 36 μg/kg of dry mat…

chemistry.chemical_classificationDetection limitScoglitti (Italy)ChromatographyPolymers and PlasticsPCA analysisChemistryOrganic ChemistryExtraction (chemistry)Sedimentautomated Soxhlet GC-MS PAHs PCA analysis PCBs Scoglitti (Italy)automated SoxhletMatrix (chemical analysis)CongenerPAHsEnvironmental chemistryPrincipal component analysisMaterials ChemistryOrganic matterPCBsGas chromatography–mass spectrometryGC-MS
researchProduct

PCB-Based Planar Inductive Loops for Partial Discharges Detection in Power Cables

2022

Partial discharge (PD) diagnosis tests, including detecting, locating, and identifying, are used to trace defects or faults and assess the degree of aging in order to monitor the insulation condition of medium- and high-voltage power cables. In this context, an experimental evaluation of three different printed circuit board (PCB)-based inductive sensor topologies, with spiral, non-spiral, and meander shapes, is performed. The aim is to assess their capabilities for PD detection along a transmission power cable. First, simulation and experimental characterization are carried out to determine the equivalent electrical circuit and the quality factor of the three sensors. PD activity was studi…

inductive loops; PCB-based inductors; partial discharges; defects detection; HV power cablespartial dischargeSettore ING-IND/31 - ElettrotecnicaHV power cablesElectrical and Electronic EngineeringPCB-based inductorBiochemistryInstrumentationAtomic and Molecular Physics and Opticsdefects detectionAnalytical Chemistryinductive loop
researchProduct

Influence of prenatal exposure to environmental pollutants on human cord blood levels of glutamate

2013

El pdf del artículo es la versión post-print.

medicine.medical_specialtyPlacentaGlutamic AcidTransport010501 environmental sciencesToxicologyPolychlorobiphenyl (PCB)01 natural sciencesUmbilical cord03 medical and health scienceschemistry.chemical_compoundGlutamatergicGlutamate Plasma Membrane Transport Proteins0302 clinical medicinePregnancyPlacentaInternal medicinemedicineHydrocarbons ChlorinatedHumansMethylmercury0105 earth and related environmental scienceschemistry.chemical_classificationChemistryGeneral NeuroscienceGlutamate receptorMethylmercuryHexachlorobenzeneMercuryFetal Blood3. Good healthAmino acidmedicine.anatomical_structureEndocrinologyBiochemistryExcitatory Amino Acid Transporter 213. Climate actionMaternal ExposureCord bloodOrganochlorine pesticidesEnvironmental PollutantsFemaleGlutamate030217 neurology & neurosurgery
researchProduct

Photochemical sample treatment: A greener approach for PCBs analysis in sediments

2012

Electrical installations and industrial outlets are the major source in environment of chlorinated organic compounds. These are distributed in several geographical areas through long-range atmospheric transport and deposition. Additionally, chlorinated organic compounds can be introduced in the food chain and reach the consumers in very high levels. Besides toxicological studies on PCBs, recent research is focusing on more sophisticated analytical methods for PCBs detection. Distribution and dispersion of PCBs mostly occur through air, water, soils, and sediments. The latter are complex matrices whose analysis often involves costly extraction and purification procedures. In particular, PCBs…

photochemical PCBs sediment green chemistrySettore CHIM/12 - Chimica Dell'Ambiente E Dei Beni Culturali
researchProduct

Składniki tworzyw sztucznych zaburzające funkcje układu nerwowego

2013

Rozwój przemysłu chemicznego spowodował opracowywanie nowych związków chemicznych niewystępujących w środowisku naturalnym. Substancje te spełniają różnorodne funkcje, takie jak obniżenie palności, zwiększenie plastyczności czy poprawienie rozpuszczalności innych substancji. Wiele związków wchodzących w skład tworzyw sztucznych, kosmetyków nowej generacji, aparatury medycznej, opakowań spożywczych oraz innych produktów codziennego użytku, z łatwością uwalniają się do środowiska naturalnego. Liczne badania wykazały, że substancje, takie jak: ftalany, BPA, TBBPA oraz PCB charakteryzują się znaczną lipofilnością dzięki czemu w łatwy sposób wnikają do żywych komórek oraz akumulują się w tkankac…

phthalatesPCBftalanyDEHPtetrabromobisfenol-A nervous systemtetrabromobisphenol-Abisphenol-A DBPreceptor estrogenowyBPAneuronTBBPAbisfenol-A ERestrogen receptorukład nerwowyPostępy Higieny i Medycyny Doświadczalnej
researchProduct