Search results for "penetration"
showing 10 items of 168 documents
Linking structure and nanomechanical properties via instrumented nanoindentations on well-defined and fine-tuned morphology poly(ethylene)
2009
Several poly(ethylene) samples with a broad range of morphologies were studied in this work using nanoindentations. The samples had degrees of crystallinity ranging from 30 to 100% while their Young's modulus ranged from few tens of MPa up to several GPa. Experimental conditions for the correct evaluation of Young's modulus were at first identified, choosing a suitable loading rate in order to minimize viscoelastic effects on the unloading. The force curves, i.e., plots of applied load vs. penetration depth, were then analyzed following two common procedures available in the literature. None of these procedures leads to satisfying results when compared to other experimental techniques. Howe…
Influence of a Crosslinker Containing an Azo Group on the Actuation Properties of a Photoactuating LCE System
2016
Photoactuating liquid crystalline elastomers (LCE) are promising candidates for an application as artificial muscles in microdevices. In this work, we demonstrate that by optimizing (1) the illumination conditions and (2) the mixture of azo monomer and azo crosslinker, thick films of an all-azo LCE can be prepared, which show a strong length change without bending during photoactuation. This becomes possible by working with white light (about 440 nm), whose absorption is low, leading to a large penetration depth. By adding an azo crosslinker to a previously prepared system, several improvements of the actuation properties—like a stronger photoactuation at lower operational temperatures—coul…
Effect of the several epoxy resin-based sealer compositions on adhesion interface in radicular dentin after calcium hydroxide intracanal medication r…
2021
Made available in DSpace on 2022-04-29T08:32:43Z (GMT). No. of bitstreams: 0 Previous issue date: 2021-09-01 Background: This study evaluated the effects of several epoxy resin-based sealer compositions (AHP, AH Plus; ADS, Adseal; SPL, Sealer Plus) on bond strength and intratubular dentin penetration of the endodontic obturation, in root canal previously treated with calcium hydroxide intracanal medication (CH) and removed by continuous ultrasonic irrigation (CUI). Material and Methods: Forty-five maxillary canines were prepared up to F5 (ProTaper system), filled with CH, coronally sealed, and stored at 37ºC. After 1 week, CH was removed using 2.5% sodium hypochlorite energized by CUI. The …
Statistical prediction of corrosion front penetration
1997
A statistical method to predict the stochastic evolution of corrosion fronts has been developed. The method is based on recording material loss and maximum front depth. In this paper we introduce the method and test its applicability. In the absence of experimental data we use simulation data from a three-dimensional corrosion model for this test. The corrosion model simulates localized breakdown of a protective oxide layer, hydrolysis of corrosion product and repassivation of the exposed surface. In the long time limit of the model, pits tend to coalesce. For different model parameters the model reproduces corrosion patterns observed in experiment. The statistical prediction method is base…
Real-Time Monitoring of Intergranular Corrosion Damage on AA2024
2017
The total porosity induced by the intergranular corrosion was selected as a monitoring parameter to follow in real-time the defect propagation of AA2024. The pertinence of eddy current (EC) probing has been tested on very thin foils of AA2024 (30 μm in thickness) in immersion conditions under potentiostatic control and in atmospheric conditions simulated by controlled salt spray experiments. Combining this nondestructive evaluation technique with a direct optical interrogation of the backside of the test specimen (derived from the foil penetration technique) allows one to discuss the contribution of both the dissolution in the depth and along the grain boundaries to the total porosity. In i…
Evaluation of the apical sealing ability and adaptation to the dentin of two resin-based Sealers: An in vitro study
2013
Aim: To quantitatively evaluate the apical sealing ability and adaptation of two resin-based sealers to dentin. Materials and Methods: Fifty freshly extracted mandibular first premolars were taken and sectioned at the cemento-enamel junction. Thirty teeth were subjected to a leakage study by the resin infiltration method with two groups of 10 teeth each. Group I teeth were obturated with methacrylate resin-based sealer (EnoRez) and Group II teeth were obturated with epoxy resin-based sealer (AH Plus). The remaining 10 teeth were used as controls (positive and negative of five teeth each). Twenty teeth were divided into two groups and obturated as in the leakage study and subjected to a scan…
Impact of root canal preparation size and taper on coronal-apical micro-leakage using glucose penetration method
2014
Objectives: The purpose of this in vitro study was to assess the effect of root canal preparation size and taper on the amounts of glucose penetration. Material and Methods: For conducting this experimental study, eighty mandibular premolars with single straight canals were divided randomly into 2 experimental groups of 30 samples each and 2 control groups. Using K-files and the balance force technique, canals in group 1 were prepared apically to size 25 and coronally to size 2 Peeso - reamer. Group 2 were instrumented apically and coronally to size 40 and size 6 Peesoreamer, respectively. Rotary instrumentation was accomplished in group 1; using size 25 and .04 tapered and in group 2, size…
Novel laser technologies for human skin in-vivo assessment
2007
Two experimental methodologies for human skin optical non-invasive in-vivo assessment have been developed and clinically tested - imaging of the laser-excited autofluorescence fading rate, and simultaneous recording of the reflectance photoplethysmography signals at several laser wavelengths with different skin penetration depths. Details of both equipments are described along with some measurement results illustrating feasibility of the novel technologies.
Challenges in automated estimation of capillary refill time in dogs
2018
Capillary refill time (CRT) is a part of the cardiorespiratory examination in dogs. Changes in CRT can reflect pathological conditions like shock or anemia. Visual CRT estimation has low repeatability; therefore, optical systems for automated estimation have recently appeared. Since existing systems are unsuitable for use in dogs, we designed a simple, small and portable device, which could be easily used at veterinary clinic. The device was preliminarily tested on several measurement sites in two dogs. Not all measurement sites were suitable for CRT measurements due to underlying tissue optical and mechanical properties. The CRT measurements were possible on the labial mucosa, above the st…
Dependence of the Optical Constant Parameters of p-Toluene Sulfonic Acid-Doped Polyaniline and Its Composites on Dispersion Solvents
2020
The optical constants of Para-Toluene sulfonic acid-doped polyaniline (PANI), PANIchitosan composites, PANI-reduced graphene-oxide composites and a ternary composite comprising of PANI, chitosan and reduced graphene-oxide dispersed in diluted p-toluene sulfonic acid (PTSA) solution and N-Methyl-2-Pyrrolidone (NMP) solvent have been evaluated and compared. The optical constant values were extracted from the absorbance spectra of thin layers of the respective samples. The potential utilization of the materials as the active sensing materials of surface plasmon resonance biosensors has also been assessed in terms of the estimated value of the penetration depth through a dielectric medium. The …