Search results for "performance"
showing 10 items of 4457 documents
Revealing transmit diversity mechanisms and their side-effects in commercial IEEE 802.11 cards
2008
Service differentiation in WLAN has been traditionally faced at the MAC layer. However, some PHY layer parameters, such as the transmission power, the antenna, and the modulation/coding scheme, have a deep impact on network performance. Since the criterion for selecting these parameters is left to the vendor specific implementations, the performance spread of most experimental results about 802.11 WLAN could be affected by vendor proprietary schemes. The focus of this paper is an experimental analysis of the undisclosed antenna diversity mechanisms employed by some widely used cards (namely, the Atheros and Intel based cards), and a thorough understanding of the optimization goals which gui…
DC link voltage swinging and load current unbalance in fault tolerant VSI. overview and compensation strategies
2015
The topic of this paper is the discussion on the performance of a three-phase fault tolerant inverter with particular attention to the underrated aspect of current unbalances occurring due to the DC link voltage fluctuates after the inverter reconfiguration. Capacitor voltage unbalance affects not only the average output voltage of the inverter, but also its performance. In fact, the inverter performance depends on the fluctuating DC-link voltage components rather than on the average DC-link voltage. After a brief analysis of the voltage fluctuation phenomena resulting from fault tolerant configuration and their effect on load current unbalance, the Authors consider different compensating p…
Effects of double ground faults in Wind Farms collector cables
2015
Medium Voltage collector cables of Wind Farms have metal shields connected to the grounding systems of the towers and of the connection station. Thanks to this bonding, when a ground fault occurs, the fault current splits itself among all the grounding systems of the wind farm, this causing a reduction of the ground potential rise at the fault location. Nevertheless, in presence of double ground faults, very high ground potential rises occur at the two fault locations and safety against electric shock is not always assured. In order to study this issue, the paper presents a model for simulating in a simple way the effects of double ground faults occurring in Medium Voltage collectors of ext…
Optimization of hybrid – ground coupled and air source – heat pump systems in combination with thermal storage
2010
Ground coupled heat pumps are attractive solutions for cooling and heating commercial buildings due to their high efficiency and their reduced environmental impact. Two possible ideas to improve the efficiency of these systems are decoupling energy generation from energy distribution and combining different HVAC systems. Based on these two ideas, we present several HVAC configurations which combine the following equipments: a ground coupled heat pump, an air to water heat pump and a thermal storage device. These HVAC configurations are linked to an office building in a cooling dominated area in order to evaluate in these conditions the total electrical consumption of each configuration to o…
Handling Underdispersion in Calibrating Safety Performance Function at Urban, Four-Leg, Signalized Intersections
2011
Poisson basic assumption of equidispersion is often too much restrictive for crash count data; in fact this type of data has been found to often exhibit overdispersion. Underdispersion has been less commonly observed, and this is the reason why it has been less convenient to model directly than overdispersion. Overdispersion and underdispersion are not the only issues that can be a potential source of error in specifying statistical models and that can lead to biased crash-frequency predictions; these issues can derive from data properties (temporal and spatial correlation, time-varying explanatory variables, etc.) or from methodological approach (omitted variables, functional form selectio…
Experimental study of low-voltage surge protection device response in realistic systems
2008
Experimental results on low-voltage surge protection under fast pulses in realistic wiring systems are presented. A fast voltage pulse generator is designed to provide fast voltage pulses with short steep fronts. The effective residual voltage of protected equipment is then investigated and compared with simulation results.
Implications of the Marketing Strategy for Exporting MSEs from Developing Economies
2010
Purpose: This paper reviews the export literature and identifies the marketing challenges faced by exporting MSEs from developing economies. The paper further explores ways in which MSEs can adjust their marketing strategies to circumvent the challenges faced. Design/methodology/approach: It reviews both theoretical and empirical perspectives in export performance globally and with a special focus on studies done in developing economies. The literature synthesis is done in order to develop a conceptual model which will be used as guidance in future research. Findings: Previous studies have shown several types of marketing challenges which are faced by MSEs from developing economies. These a…
Control of solid-state fault current limiter for DG-integrated distribution systems
2017
Fault current limier (FCL) is a device that limits the system current under fault conditions without disconnecting the system and affecting the power system protection components such as circuit breakers. Many types of FCLs have been proposed to limit the magnitude of the fault current. Solid-state fault current limiters (SSFCLs) can limit the peak value of the fault current by applying several methods, such as controlling the system impedance or controlling the voltage that appears across the fault. In this paper, a new control scheme for the SSFCL circuit is presented. The control method is based on controlling the duty cycle of solid state switches to control the rms value of the system …
Current and Voltage Behaviour During a Fault in a HV/MV System: Methods and Measurements
2015
When a single line to ground fault happens on the MV side of a HV/MV system, only a small portion of the fault current is injected into the ground by the ground-grid of the faulty substation. In fact the fault current is distributed between grounding electrodes and MV cables sheaths. In systems with isolated neutral or with resonant earthing this may be sufficient to provide safety from electric shock. Experimental measurements were performed on a real MV distribution network: a real single line to ground fault was made and fault currents were measured in the faulty substation and in four neighbouring substations. In this paper the problem of fault current distribution is introduced, the te…
Design, Building up and First Results of Three Monitored Green Coverings Over a University Department Building
2015
Abstract A viable solution to reducing the buildings’ energy demand is the implementation of green coverings that have been demonstrated to improve the envelope performance, especially in summer season. Anyway, to apply computer models analyzing the energy performance of buildings equipped with such components, the knowledge of specific parameters is needed. Among these, the fractional vegetation coverage and leaf area index are of great importance. By means of an experimental facility, first results of the evaluation of these foliage-related parameters for five types of vegetation are presented.