Search results for "performance"
showing 10 items of 4457 documents
Comparative study of solvation parameter models accounting the effects of mobile phase composition in reversed-phase liquid chromatography
2007
Solvation parameter models relate linearly compound properties with five fundamental solute descriptors (excess molar refraction, dipolarity/polarizability, effective hydrogen-bond acidity and basicity, and McGowan volume). These models are widely used, due to the availability of protocols to obtain the descriptors, good performance, and general applicability. Several approaches to predict retention in reversed-phase liquid chromatography (RPLC) as a function of these descriptors and mobile phase composition are compared, assaying the performance with a set of 146 organic compounds of diverse nature, eluted with acetonitrile and methanol. The approaches are classified in two groups: those t…
Performance of a Chromolith RP-18e column for the screening of β-blockers
2009
The chromatographic performance of a monolithic column (Chromolith RP-18e) was comprehensively examined in the isocratic separation of ten beta-blockers, using ACN-water mobile phases, and compared with the performance of three microparticulate RP columns manufactured with different types of silica: Spherisorb ODS-2, Kromasil C18 and XTerra MS C18. The comparison considered the analysis time, selectivity, peak shape (column efficiency and asymmetry) and resolution, and was extended to a wide range of mobile phase compositions. The Chromolith column showed good performance for the analysis of beta-blockers with regard to the packed columns. In terms of selectivity and analysis time, the grea…
Prediction of peak shape in hydro-organic and micellar-organic liquid chromatography as a function of mobile phase composition
2007
A simple model is proposed that relates the parameters describing the peak width with the retention time, which can be easily predicted as a function of mobile phase composition. This allows the further prediction of peak shape with global errors below 5%, using a modified Gaussian model with a parabolic variance. The model is useful in the optimisation of chromatographic resolution to assess an eventual overlapping of close peaks. The dependence of peak shape with mobile phase composition was studied for mobile phases containing acetonitrile in the presence and absence of micellised surfactant (micellar-organic and hydro-organic reversed-phase liquid chromatography, RPLC). In micellar RPLC…
Interpretive optimisation strategy applied to the isocratic separation of phenols by reversed-phase liquid chromatography with acetonitrile–water and…
2000
An optimisation protocol is presented for the resolution of complex mixtures in isocratic RPLC with binary mobile phases of organic solvent and water, which is based on the prediction of peak position and shape of the individual compounds. A good description of the retention was achieved through the application of statistical weights to the widely used linear or quadratic relationships between the logarithm of the retention factor (log k) and the organic solvent concentration in the mobile phase. The maximisation of the product of peak purities for each compound is shown as a competitive resolution strategy versus the worst value of a selectivity parameter. Peak purities allow one to associ…
Peak half-width plots to study the effect of organic solvents on the peak performance of basic drugs in micellar liquid chromatography.
2009
The addition of the anionic surfactant sodium dodecyl sulphate (SDS) to hydro-organic mixtures of methanol, ethanol, propanol or acetonitrile with water yielded enhanced peak shape (i.e. increased efficiencies and symmetrical peaks) for a group of basic drugs (β-blockers) chromatographed with a Kromasil C18 column. The effect can be explained by the thin layer of surfactant associated to the hydrocarbon chain on the stationary phase in the presence of the organic solvents, which covers the free silanols on the siliceous support avoiding their interaction with the cationic basic drugs. These instead interact with the anionic head of the surfactant increasing their retention and allowing a mo…
Development of a sensitive method for the determination of acrylamide in coffee using high-performance liquid chromatography coupled to a hybrid quad…
2015
The emerging trend towards high-resolution mass spectrometry (MS) alternatives was evaluated by the application of Orbitrap MS for the determination of acrylamide in coffee samples. The high resolving power of the Orbitrap MS provided the high selectivity and sensitivity that enabled quantitative analysis of acrylamide in complex matrices, such as coffee. Several sample preparation methods and scanning modes of the MS (full MS, t-SIM, t-MS2) were assessed in order to optimise parameters of the analytical method. The final procedure involved the extraction of acrylamide with acetonitrile, solid-phase extraction with dispersive primary secondary amine (PSA) and amino columns, and the detectio…
Avoiding accidents at the champagne reception: A study of joint lifting and balancing
2017
Using a lifting and balancing task, we contrasted two alternative views of planning joint actions: one postulating that joint action involves distinct predictions for self and other, the other postulating that joint action involves coordinated plans between the coactors and reuse of bimanual models. We compared compensatory movements required to keep a tray balanced when 2 participants lifted glasses from each other’s trays at the same time (simultaneous joint action) and when they took turns lifting (sequential joint action). Compared with sequential joint action, simultaneous joint action made it easier to keep the tray balanced. Thus, in keeping with the view that bimanual models are reu…
Immersive Versus Non-immersive Experience: Exploring the Feasibility of Memory Assessment Through 360° Technology
2019
Episodic memory is essential to effectively perform a number of daily activities, as it enables individuals to consciously recall experiences within their spatial and temporal environments. Virtual Reality (VR) serves as an efficacious instrument to assess cognitive functions like attention and memory. Previous studies have adopted computer-simulated VR to assess memory, which realized greater benefits compared to traditional procedures (paper and pencil). One of the most recent trends of immersive VR experiences is the 360° technology. In order to evaluate its capabilities, this study aims to compare memory performance through two tasks: immersive task and non-immersive task. These tasks d…
Exposure-Based Cash-Flow-At-Risk for Value-Creating Risk Management Under Macroeconomic Uncertainty
2010
A strategically minded CFO will realize that strategic corporate risk management is about finding the right balance between risk prevention and proactive value generation. Efficient risk and performance management requires adequate assessment of risk and risk exposures on the one hand and performance on the other. Properly designed, a risk measure should provide information on to what extend the firm's performance is at risk, what is causing that risk, the relative importance of non-value-adding and value-adding risk, and the possibilities to use risk management to reduce total risk. In this chapter, we present an approach – exposure-based cash-flow-at-risk – to calculating a firm's downsid…
Portfolio performance evaluation with loss aversion
2011
In this paper we consider a loss-averse investor equipped with a specific, but still quite general, utility function motivated by behavioral finance. We show that, under certain concrete assumptions concerning the form of this utility, one can derive closed-form solutions for the investor's portfolio performance measure. We investigate the effects of loss aversion and demonstrate its important role in performance measurement. The framework presented in this paper also provides a sound theoretical foundation for all known performance measures based on partial moments of the distribution.