Search results for "performance"
showing 10 items of 4457 documents
Interpretive optimisation of organic solvent content and flow-rate in the separation of β-blockers with a Chromolith RP-18e column
2009
The chromatographic performance of a Chromolith RP-18e column was comprehensively examined for a group of basic drugs (beta-blockers), eluted with isocratic ACN-water mixtures at increasing flow-rate up to 6 mL/min. As the flow-rate increases at fixed mobile phase composition, peak distribution (selectivity) is maintained, but the relative peak widths increase. This reduces the resolution below satisfactory values for closely eluting compounds. With the monolithic column, flow-rate becomes thus an important factor to be optimised, in addition to the mobile phase composition. Since, theoretically, retention factors (k) are independent of the flow-rate, the classical quadratic model relating …
Impact of pore structural parameters on column performance and resolution of reversed-phase monolithic silica columns for peptides and proteins
2007
In this work, monolithic silica columns with the C4, C8, and C18 chemistry and having various macropore diameters and two different mesopore diameters are studied to access the differences in the column efficiency under isocratic elution conditions and the resolution of selected peptide pairs under reversed-phase gradient elution conditions for the separation of peptides and proteins. The columns with the pore structural characteristics that provided the most efficient separations are then employed to optimize the conditions of a gradient separation of a model mixture of peptides and proteins based on surface chemistry, gradient time, volumetric flow rate, and acetonitrile concentration. Bo…
Critical study of and improvements in chromatographic methods for the analysis of type B trichothecenes
2001
Various analytical methods used in the analysis of type B trichothecenes (deoxynivalenol, nivalenol, 3- and 15-acetyldeoxynivalenol) in cereals were compared and optimised in this work. These methods use either GC-electron-capture detection (ECD) of trimethylsilyl, trifluoroacetyl and heptafluorobutyryl derivatives or HPLC with UV or photodiode array detection of analytes. A new HPLC procedure using fluorescence detection prior derivatisation with coumarin-3-carbonyl chloride has been also tested. Five extraction solvents and two solid-phase extraction cartridges (silica, Florisil) plus a especial clean-up column (MycoSep 225) were compared in order to obtain the best recovery of the mycoto…
Quantitative retention–structure and retention–activity relationships of barbiturates by micellar liquid chromatography
1998
Abstract Studies on the structural requirements of chromatographic surfaces to emulate in vitro the partitioning process in biomembranes are of great interest. The use of micellar mobile phases in RPLC modifies the hydrophobicity of the stationary phase and provides hydrophobic and electrostatic sites of interaction as a consequence of the adsorption of surfactant monomers to the chromatographic surface. Modified stationary phases in MLC could be structurally similar to biomembranes, but thorough studies are necessary to confirm this. In this paper we focus our attention on barbiturates. The influence of the nature and concentration of the surfactant (Brij 35, SDS and CTAB) and the mobile p…
High-resolution gas chromatographic-mass spectrometric determination of neutral chlorinated aromatic sulphur compounds in stack gas samples
1993
Abstract Four stack gas samples from waste incineration were analysed by high-resolution GC-MS for neutral chlorinated aromatic sulphur compounds such as polychlorinated dibenzothiophenes, thianthrenes and diphenyl sulphides. Samples were analysed tentatively also for some methylated derivatives of these compounds. The stack gas samples had earlier been found to contain some tri- and tetrachlorodiphenyl sulphides. Two of the stack gas samples contained tetra- and pentachlorodibenzothiophenes. One sample was strongly suspected to contain some tri- and tetrachlorothianthrenes in low concentrations. No methylated derivatives of these compounds could be found. Polychlorothianthrenes, some polyc…
Capabilities of different liquid chromatography tandem mass spectrometry systems in determining pesticide residues in food
2007
Abstract Three different liquid chromatography–mass spectrometry (LC–MS) instruments equipped with triple quadrupole (QqQ), quadrupole ion trap (QIT) and quadrupole-time-of-flight (QqTOF), suitable to carry out tandem mass spectrometry, were examined to determine pesticide residues in food. Twelve pesticides (acrinathrin, bupirimate, buprofezin, cyproconazole, λ-cyhalothrin, fluvalinate, hexaflumuron, kresoxim-methyl, propanil, pyrifenox, pyriproxyfen and tebufenpyrad) and six matrices (oranges, strawberries, cherries, peaches, apricots and pears) were taken as model. The comparison was focused on two aspects: the quantitative, covering sensitivity, precision and accuracy as well as the qua…
1-Naphthyl Acetate-Dependent Medium Acidification by Zea mays L. Coleoptile Segments
1991
Zea mays L. cv INRA 5a coleoptile segments ecidify the incubation medium on the addition of 1-naphthyl acetate (1-NA). The buffering capacity of the bathing solution increases during 1-NA stimulated medium acidification. The solution bathing the 1-NA treated coleoptile segment was analyzed by high performance liquid chromatography. A considerable amount of acetic acid was detected in the bathing solution used to measure 1-NA-dependent medium acidification. For the first time, the data demonstrate directly the release of acetic acid from 1-NA. The extent of medium acidification was proportional to 1-NA concentration. Simultaneous measurement of medium acidification and acetate content upon a…
MALDI-TOF characterization of macromonomers
1996
Methacryloyl endfunctionalized oligostyrene macromonomers were characterized by matrix assisted laser desorption ionization/time of flight (MALDI-TOF) spectroscopy and by isocratic and gradient high performance liquid chromatography (HPLC). The molar mass distribution derived by the different techniques coincide for the investigated oligomers. Mixing experiments revealed that the MALDI-TOF peak areas do not necessarily represent the mixing ratio of the components. Combination of gradient HPLC and MALDI-TOF has resolved the chemical composition of the coupling products formed by reaction of the living anion with oxygen.
Optimization of the phase system in the analysis of polynuclear aromatics (PNA) from diesel engine exhaust by high performance liquid chromatography …
1979
Polynuclear aromatics (PNA) were collected and enriched from diesel engine exhausts by means of a probe and an absorber system. Group separation of PNA from other constituents of exhaust was accomplished through elution with n-heptane on a silica column. A variety of phase systems ranging from unpolar to strong polar packings and eluents, respectively, were tested to resolve PNA into single species. Of these a n-octadecyl bonded silica packing and methanol/water was found to be the most optimal with regard to resolution for real PNA mixtures. Separation was completed within 2–3 h at isocratic conditions.
Limits of multi-linear gradient optimisation in reversed-phase liquid chromatography
2005
Abstract The concept of limiting peak purity was applied to quantify the degree of completion of the separation capability of a chromatographic system using multi-linear gradients. The objective was to check whether the complexity of a gradient program deserves be increased to enhance resolution by inserting more linear segments, or on the contrary, no significant improvements can be expected under more complex gradients. A set of 19 isoindole derivatives of primary amino acids was selected to test the performance of isocratic, single linear and multi-linear gradients. Accurate simulated chromatograms were obtained via numerical integration of the general equation of gradient elution, using…