Search results for "perioperative"
showing 10 items of 332 documents
Impact of perioperative transfusions and sepsis on long-term oncologic outcomes after curative colon cancer resection. A retrospective analysis of a …
2020
Objective: Intra-abdominal septic complications (IASC) affect short-term outcomes after surgery for colon cancer. Blood transfusions have been associated with worse short-term results.The role of IASC and blood transfusions on long-term oncologic results is still debated. This study aims to assess the impact of these two variables on survival after curative colon cancer resection. Patients and methods: Retrospective analysis of a prospectively maintained database of patients who underwent curative surgery for colon cancer at a university hospital, between 1993 and 2010. Cox regression was used to identify the role of IASC and transfusions (alone and combined) on local recurrence (LR), disea…
Use of covered chimney stents for pararenal aortic pathologies is safe and feasible with excellent patency and low incidence of endoleaks.
2012
Background To present the clinical experience of consecutive series with use of balloon-expandable and self-expanding chimney endografts (balloon-expandable covered stent group [BECS] vs self-expanding covered stent group [SECS]) in the endovascular treatment of challenging aortic pathologies requiring renal and/or visceral revascularization. Methods Between January 2009 and May 2011, data for 37 high-risk patients from one center and 35 patients from another institution, with pararenal aortic pathologies treated by the chimney endovascular technique, were prospectively collected. The chimney-graft technique is based on the deployment of a covered or bare-metal stent parallel to the aortic …
Value of the deep femoral artery as alternative inflow source in infrainguinal bypass surgery.
2013
Background The purpose of this study was to analyze the long-term results of infrainguinal bypass surgery using the deep femoral artery (DFA) as the inflow source. Methods Between 1998 and 2011, 88 bypasses of the lower limb were placed in 86 patients (mean age 71 years) using the deep femoral artery as inflow. Patients' records were retrieved from a computerized database and analyzed retrospectively. Results Critical limb ischemia (rest pain/tissue loss) was the indication in the majority (87.5%) of cases. The distal anastomosis of the bypass grafts was located at the popliteal level in 32 cases and the tibial (pedal) level in 52 cases, respectively, with the autologous vein as conduit in …
Early outcomes with a single-sided access endovascular stent
2018
Abstract Objective The objective of this study was to report the 1-year follow-up study results of the new Horizon stent graft (Endospan, Herzliya, Israel) from two different prospective consecutive trials. The Horizon abdominal aortic aneurysm stent graft system is a 14F profile system requiring only a single access site. It consists of three modules, introduced separately: base limb (iliac to iliac limb); distal aortic limb; and proximal aortic limb with a bare suprarenal crown and active fixation. Methods Data from the first in man (FIM) clinical study with 10 patients enrolled and the pivotal study with 30 patients were analyzed. Outcomes measured were freedom from major adverse events …
The TiLOOP® Male Sling: Did We Forejudge.
2017
<b><i>Introduction:</i></b> To evaluate the safety and efficacy of the TiLOOP® male sling (pfm medical, Cologne, Germany) used in the treatment for male stress urinary incontinence (SUI). <b><i>Material and Methods:</i></b> We retrospectively evaluated a total of 34 patients with a TiLOOP® male sling. Perioperative complication rates were assessed and validated questionnaires were prospectively evaluated to assess quality of life and satisfaction rate. Outcome and complication rates were analysed by using descriptive statistics. Correlation of continence outcome and risk factors was performed with the chi-square test. A <i>p</i> va…
CT Angiography at 24 Months Demonstrates Durability of EVAR With the Use of Chimney Grafts for Pararenal Aortic Pathologies
2013
PURPOSE: To present the 24-month radiological follow-up data for patients with pararenal aortic pathologies treated with chimney and periscope grafts during endovascular repair. METHODS: Between January 2008 and December 2011, 124 high-risk patients with complex pararenal aortic pathologies were treated using the chimney technique at 2 European vascular and cardiovascular centers with advanced experience of the described technique. In particular, 50 patients were treated at Site 1 and 74 at Site 2. Forty (32.2%) patients (32 men; mean age 79.2±4.9 years) completed computed tomographic angiography follow-up at 24 months postoperatively. RESULTS: The overall technical success was 100%, and th…
Urethral fixation technique improves urinary continence recovery in men undergoing open radical cystectomy and ileal orthotopic neobladder
2021
Background We assessed urinary continence recovery and perioperative complications in patients operated on with the novel urethral fixation technique during open radical cystectomy (RC) with ileal orthotopic neobladder (IONB). Methods A retrospective cohort of 82 consecutive male patients undergoing open RC with IONB between 07/2013 and 06/2020 was analyzed. A study group of 48 patients operated on with the urethral fixation technique was compared with a control group of 34 patients receiving standard neovesico-urethral anastomosis. In the study group, the urethral stump was fixed to the dorsal median raphe posteriorly and to the medial portion of levator ani muscle postero-laterally in ord…
Transrectal ultrasound guided implantation of the ProACT adjustable continence therapy system in patients with post-radical prostatectomy stress urin…
2006
Purpose: We evaluate the feasibility and potential advantages of ProACT system implantation using transrectal ultrasound rather than fluoroscopy for guidance. Materials and Methods: The transrectal ultrasound guided procedure was done between June and October 2005 in 7 patients with a mean age of 68.4 years (range 53 to 76) with mild to severe stress urinary incontinence after laparoscopic transperitoneal radical prostatectomy. Results: The ProACT system was successfully implanted in all cases without perioperative complications. Time needed to complete the overall procedure was 15 to 30 minutes. All transrectal ultrasound studies performed during the mean followup of 4.2 months (range 2 to…
Intraoperative ultrasound-assisted approach for endoscopic treatment of vesicoureteral reflux in children
2017
Purpose Despite minimal invasiveness and high success rate, guidelines still prescribe voiding Cystourethrogram (VCUG) after endoscopic treatment for vesicoureteral reflux (VUR) in children. The aim of this paper was to analyze whether intraoperative ultrasound (IO-US) could improve surgical accuracy and perioperative counseling, thus potentially decreasing the need for postoperative VCUG. Methods We selected children treated for moderate to high grade VUR, renal scarring or repeated infections under antibiotic prophylaxis from January to December 2015. Endoscopic injection was combined with IO-US to detect optimal needle placement and to guide mound formation. IO-US findings were compared …
Surgical conversion with graft salvage as a definitive treatment for persistent type II endoleak causing sacenlargement
2015
Objective The goal of this study was to present open surgical conversion with graft salvage or "semiconversion" as a definitive and safe treatment for untreatable and persistent type II endoleaks causing sac enlargement after endovascular aneurysm repair. Methods Between January 2001 and December 2014, 25 of 1623 endovascular aortic repair (EVAR) patients were selected as candidates for open semiconversion. The indication was persistent type II endoleak in 13 patients (12 of whom received previous attempts of embolization), type I and II endoleak in 2 patients, and sac growth without imaging evidence of endoleak in the other 10. After the infrarenal aorta was prepared (via a retroperitoneal…