Refractive and Visual Results after Implantation of the AcrySof ReSTOR IOL in High and Low Hyperopic Eyes
2009
To assess the differences in refractive and visual results obtained in eyes with high and low hyperopia after implantation of a multifocal intraocular lens (IOL).A prospective study was performed on 172 hyperopic eyes implanted with the AcrySof Re-STOR Natural (SN60D3) IOL. Two groups were created, high and low hyperopes (86 eyes in both cases). We analyzed monocular visual acuity for distance and near, with and without distance correction. Photopic and mesopic contrast sensitivity (CS) were also assessed. All measurements were performed at 6 months after surgery.Monocular best distance-corrected visual acuity was 0.01+/-0.03 logMAR for low hyperopes and 0.04+/-0.10 logMAR for high hyperope…
Optical quality of the eye after lens replacement with a pseudoaccommodating intraocular lens
2007
To examine the optical quality of healthy presbyopic eyes before and after implantation of the pseudoaccommodating AcrySof ReSTOR Natural intraocular lens (IOL) (Alcon Laboratories) by measuring visual acuity and wavefront aberrations.University of Valencia, Fernández-Vega Ophthalmological Institute, Valencia, Spain.Monocular refraction and photopic distance (6 m) and near (0.33 m) visual acuities were determined before and after clear lens extraction with bilateral AcrySof ReSTOR Natural IOL implantation in 30 hyperopic eyes (+0.50 to +4.00 diopters [D]) of presbyopic patients with low astigmatism (or = 1.00 D). Postsurgical binocular visual acuity was measured over a range of effective di…
Effect of partial and full correction of corneal spherical aberration on visual acuity and contrast sensitivity
2008
A 60-year-old white man had cataract surgery with an AcrySof IQ intraocular lens (IOL) implanted in the right eye and a Tecnis IOL implanted in the left eye. The ocular spherical aberration (SA) target for a 6.0 mm pupil was +0.10 microm for the right eye and 0 microm for the left eye. After surgery, the ocular SA in the right eye was significantly higher than that in the left eye (+0.112 microm +/- 0.002 [SD] versus +0.021 +/- 0.003 microm; P.001). No between-eye difference in the best corrected visual acuity and photopic contrast sensitivity was found. The contrast sensitivity was significantly better in the eye with the AcrySof IQ IOL at 12 and 18 cpd under mesopic conditions. The best c…
Pseudoaccommodating intraocular lens implantation in patients with irregular nonreactive pupils.
2007
We report 3 patients implanted with the AcrySof ReSTOR pseudoaccommodating intraocular lens (IOL) who had irregular nonreactive pupils as a consequence of pupil stretching during phacoemulsification. Despite the pupils, the visual acuity at distance and near was not compromised. The outcome in these cases suggests that an irregular nonreactive pupil is not an exclusion criterion for pseudoaccommodating IOL implantation.
Late postoperative opacification of MemoryLens hydrophilic acrylic intraocular lenses Case series and review
2003
Abstract Purpose: To report clinical and spectrographic analyses of 2 explanted hydrophilic acrylic intraocular lenses (IOLs). Setting: John A. Moran Eye Center, Salt Lake City, Utah, USA, and Johannes Gutenberg-University, Department of Ophthalmology, Mainz, Germany. Methods: We report 6 cases of opacification of MemoryLens ® IOLs (Ciba Vision) that occurred approximately 2 years after implantation. The anterior and posterior surfaces of the IOLs had a white, frosted appearance, and the IOLs' interior looked brown, similar to the appearance of a brunescent cataract. Two of the IOLs were explanted because of a significant decrease in visual acuity. The IOLs were sent for further clinicopath…
Refractive Lens Exchange with Foldable Toric Intraocular Lens
2009
To assess visual and refractive outcomes, and rotational stability after refractive lens exchange (RLE) with toric intraocular lens (IOL) implantation to correct ametropia and preexisting astigmatism.Prospective, nonrandomized, observational case series (self-controlled).This prospective, nonrandomized, and self-controlled study included 32 eyes of 19 consecutive patients with more than 1.00 diopter (D) of preexisting corneal astigmatism having RLE with AcrySof Toric IOL implantation (Alcon Laboratories Inc, Fort Worth, Texas, USA). Uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), refractive sphere, and keratometric and refractive cylinder were recorded preoperatively …
Stereoacuity After Refractive Lens Exchange With AcrySof ReSTOR Intraocular Lens Implantation
2009
Purpose: To evaluate stereoacuity before and after refractive lens exchange (RLE) with AcrySof ReSTOR intraocular lens (IOL) implantation. Methods: Stereoacuity was measured using the Titmus stereotest at 40 cm under photopic conditions (85 cd/m 2 ) before and after RLE with bilateral AcrySof ReSTOR Natural (SN60D3 model) implantation in 30 hyperopic eyes of presbyopes with low astigmatism (⩽1.00 diopter [D]). Stereoacuity measurements after implantation were compared with those found before surgery. Results: Stereoacuity was unchanged after RLE with pseudoaccommodative IOL implantation. In this population of non-cataractous hyperopes with excellent preoperative stereoacuity (46.42±1.36 se…
Visual function after implantation of an aspheric bifocal intraocular lens.
2009
Purpose To evaluate distance, intermediate, and near vision after bifocal aspheric AcrySof ReSTOR SN6AD1 intraocular lens (IOL) implantation. Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Methods Binocular distance best corrected visual acuity (BCVA) (4.0 m), best distance-corrected near (40.0 cm) and intermediate (70.0, 60.0, 50.0 cm) acuities, and contrast sensitivity under photopic (85.0 candelas [cd]/m 2 ) and mesopic (3.0 cd/m 2 ) conditions with and without glare were measured postoperatively. A patient-satisfaction and visual phenomena questionnaire was administered. Results Six months postoperatively, the mean acuities (logMAR) were binocular BCVA, −0.064 ± 0.049…
Visual function after bilateral implantation of a new zonal refractive aspheric multifocal intraocular lens.
2011
Purpose To evaluate visual function after bilateral implantation of a zonal refractive aspheric multifocal intraocular lens (IOL). Setting Private practice surgery center, Valencia, Spain. Design Cohort study. Methods Consecutive eyes with cataract had bilateral implantation of Lentis Mplus LS-312 multifocal IOLs. Distance, intermediate, and near visual acuities; contrast sensitivity; defocus curves; and a quality-of-vision questionnaire, including presence of halos or dysphotopsia, were evaluated 6 months postoperatively. A control group of age-matched monofocal pseudophakic patients was included to compare contrast sensitivity function. Results In the multifocal group, the mean binocular …
Multifocal intraocular lenses for unilateral cataract in children.
2009
Purpose To evaluate the implantation of apodized diffractive multifocal intraocular lenses (IOLs) in children with unilateral cataract. Setting Ophthalmology Service, Hospital Clinico Lozano Blesa, Zaragoza, Spain. Design Prospective clinical study. Methods Five children between 4 and 6 years of age with unilateral cataract had cataract extraction and implantation of an apodized diffractive multifocal IOL (AcrySof Restor SN60D3). Phacoaspiration was accompanied by posterior capsulorhexis followed by an anterior vitrectomy. Uncorrected distance (UDVA), corrected distance (CDVA), and corrected near (CNVA) visual acuities; binocular function using the Worth 4-dot test and the TNO stereotest; a…