Search results for "phakic"

showing 10 items of 51 documents

Phake Intraokularlinsen

2004

Phakic intraocular lenses (PIOLs), which are located closer to the eye's nodal points than the anterior corneal surface, can provide superior optical quality for higher corrections because of retention of normal prolate corneal asphericity and larger effective optical zones. Improvements in the material and design of phakic intraocular lenses and their insertion devices combined with advances in the understanding of the anatomical and physiological interactions of the PIOLs with intraocular structures, have increased safety and efficacy. Safety of these implants over the long term remains a concern, but in several situations PIOLs are the refractive correction of choice. The purpose of this…

Refractive errorgenetic structuresbusiness.industryCorneal asphericityProlate spheroidAstigmatismmedicine.diseasePhakic intraocular lenseye diseasesOptical qualitylaw.inventionLens (optics)OphthalmologylawMedicineOptometrysense organsCorneal surfacebusinessDer Ophthalmologe
researchProduct

Surgical management of acute angle-closure glaucoma after toric implantable contact lens implantation

2006

A case of pupillary block after implantation of an implantable contact lens (ICL) is reported, and surgical management and prevention are discussed. In a myopic patient, the best corrected visual acuity in the right eye was 20/50 with -15.50 -3.00 x 175. After uneventful implantation of an ICL, painful acute glaucoma developed with an intraocular pressure beyond measurable values. Apparent anterior vaulting of the ICL suggested a sizing problem. In a situation of a mid-wide dilated pupil, immediate explantation of the ICL was performed. Then, using a preoperative iris photography as guidance, an anterior chamber iris-claw toric phakic intraocular lens was implanted. On postoperative examina…

Reoperationmedicine.medical_specialtyIntraocular pressuregenetic structuresContact LensesVisual AcuityPhakic intraocular lensPupilLens Implantation IntraocularOphthalmologyMyopiamedicineHumansIris (anatomy)Device RemovalIntraocular PressurePupillary blockbusiness.industryeye diseasesSensory SystemsSurgeryOphthalmologymedicine.anatomical_structureIris DiseasesAcute angle-closure glaucomaImplantable Contact LensLens (anatomy)Acute DiseaseSurgerysense organsGlaucoma Angle-ClosurebusinessJournal of Cataract and Refractive Surgery
researchProduct

Optical quality comparison between 2 collagen copolymer posterior chamber phakic intraocular lens designs

2014

Purpose To compare the optical quality in vitro of 2 designs of the Visian Implantable Collamer Lens phakic intraocular lens (pIOL) for different powers and optical apertures. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The Nimo TR1504 deflectometry device was used to measure the V4c pIOL, which has a smaller optic diameter, and the V5 pIOL, which has a larger optic diameter. The pIOLs were measured for −3.00 diopters (D), −6.00 D, −9.50 D, and −10.50 D at different optical apertures from 3.00 to 6.00 mm depending on the IOL power and model. The root mean square of higher-order aberrations (RMS HOAs) was analyzed. The Strehl ratio, point-spread functi…

WavefrontOptics and PhotonicsPhakic Intraocular LensesMaterials sciencePolymersApertureZernike polynomialsbusiness.industryStrehl ratioPupilProsthesis DesignRefraction OcularPhakic intraocular lensSensory SystemsRoot mean squareOphthalmologySpherical aberrationsymbols.namesakeOpticssymbolsHumansSurgeryCollagenbusinessDioptreJournal of Cataract and Refractive Surgery
researchProduct

Implantable collamer lens with central hole: 3-year follow-up.

2018

Luis Fernández-Vega-Cueto,1 Carlos Lisa,1 José J Esteve-Taboada,2 Robert Montés-Micó,2 José F Alfonso1,3 1Department of Surgery, Fernández-Vega Ophthalmological Institute, Oviedo, Spain; 2Department of Optics and Optometry and Visual Sciences, University of Valencia, Valencia, Spain; 3School of Medicine, University of Oviedo, Oviedo, Spain Purpose: To evaluate the long-term predictability, stability, safety, and efficacy of the V4c Visian implantable collamer lens (ICL) with central hole to correct myopia.Patients and methods: One hundred and eighty-four eyes of 92 patients were evaluated during 3 years after implantation of …

medicine.medical_specialtyDistance visual acuitygenetic structuresVisian ICLeducationEmmetropiaSpherical equivalentPhakic intraocular lensEndothelial cell count03 medical and health sciences0302 clinical medicineOphthalmologyMedicinehealth care economics and organizationsOriginal ResearchImplantable collamer lensbusiness.industryimplantable collamer lensClinical Ophthalmologyeye diseasesOphthalmologylong-term evaluation030221 ophthalmology & optometrybusinessphakic intraocular lens030217 neurology & neurosurgeryClinical ophthalmology (Auckland, N.Z.)
researchProduct

Toric phakic intraocular lens

2003

Abstract Objective To evaluate safety, efficacy, predictability, stability, complications, and patient satisfaction after implantation of Artisan toric phakic intraocular lenses (TPIOLs) for the correction of myopia or hyperopia with astigmatism. Design Prospective, nonrandomized, comparative (self-controlled) multicenter trial. Participants Seventy eyes of 53 patients (mean, 35 years; range, 22–59 years) with preoperative spherical equivalent between +6.50 and −21.25 diopters (D) and cylinder between 1.50 and 7.25 D. Methods Seventy eyes underwent implantation of a TPIOL with an optical zone of 5.0 mm (Artisan, Ophtec, Groningen, The Netherlands). The dioptric power of the intraocular lens…

medicine.medical_specialtyRefractive errorVisual acuitygenetic structuresKeratometerbusiness.industrymedicine.medical_treatmentIntraocular lensAstigmatismmedicine.diseasePhakic intraocular lenseye diseaseslaw.inventionToric lensOphthalmologylawOphthalmologymedicinesense organsmedicine.symptombusinessDioptreOphthalmology
researchProduct

Changes in higher-order aberrations after implantation of a foldable iris-claw lens in myopic phakic eyes

2006

Purpose To evaluate the change in higher-order aberrations (HOAs) after implantation of a foldable iris-claw phakic intraocular lens (pIOL) in myopic eyes. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods This prospective nonrandomized comparative self-controlled trial included 41 eyes that had implantation of a foldable iris-claw pIOL between July 2003 and November 2004. All patient data for HOAs (Zernike coefficient) were measured and calculated using the same pupil size preoperatively and postoperatively, and the root-mean-square (RMS) wavefront error was calculated. Examinations were performed preoperatively as well as 1 week and 3, 6, and 12 m…

medicine.medical_specialtyRefractive errorgenetic structuresAnterior ChamberEye diseaseVisual AcuityIrisPhakic intraocular lensCorneaVision disorderLens Implantation IntraocularOphthalmologyLens CrystallineMyopiaHumansMedicineProspective StudiesIris clawDioptreLenses Intraocularbusiness.industryRefractive Errorsmedicine.diseaseeye diseasesSensory SystemsOphthalmologyAberrations of the eyemedicine.anatomical_structureLens (anatomy)Silicone ElastomersSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Descemet Membrane Endothelial Keratoplasty for Corneal Decompensation Secondary to Phakic Intraocular Lenses

2019

Purpose. To describe the surgical technique and clinical outcomes of bilensectomy (pIOL explant and phacoemulsification), followed by DMEK performed for bullous keratopathy secondary to pIOL.Methods. Seven eyes of seven patients, who developed corneal decompensation after pIOL implantation, underwent bilensectomy followed by DMEK in a two-step procedure. Main outcome measures included uncorrected visual acuity (UCVA) and best-corrected visual acuity (BCVA), refraction, endothelial cell density (ECD) at 1, 3, 6, and 12 months, and intraoperative and postoperative complications.Results. DMEK was performed at a mean time of 9.83 ± 8.23 months after bilensectomy. BCVA (log MAR) improved in all …

medicine.medical_specialtyVisual acuityDescemet membraneCorneal Decompensationgenetic structuresArticle Subjectbusiness.industrymedicine.medical_treatmentUncorrected visual acuityPhacoemulsificationPhakic intraocular lenseye diseasesOphthalmologylcsh:Ophthalmologylcsh:RE1-994OphthalmologyBullous keratopathymedicinePrimary graft failuremedicine.symptombusinessResearch ArticleJournal of Ophthalmology
researchProduct

Preliminary in vivo positional analysis of a posterior chamber phakic intraocular lens by optical coherence tomography and its correlation with clini…

2012

Purpose: To analyze by spectral-domain optical coherence tomography the anatomical relationship of a specific type of posterior chamber phakic intraocular lens (pIOL) implanted in cases of high to moderate myopia with the adjacent intraocular structures and to correlate it with clinical outcomes. Methods: Prospective observational case series including 18 eyes with high to moderate myopia (spherical equivalent between −5.88 and −15.75 D) of 9 patients (age range, 29–49 years) undergoing bilateral Phakic Refractive Lens (PRL, Zeiss) implantation. Postoperative visual acuity, refraction, contrast sensitivity (CS), and ocular higher order aberrations (HOA) were evaluated. Furthermore, the in v…

medicine.medical_specialtygenetic structuresSpectral domainPositional analysislcsh:OphthalmologyOptical coherence tomographyIn vivoOphthalmologymedicinelcsh:QC350-467Optical coherence tomographymedicine.diagnostic_testbusiness.industrySpectral-domaineye diseasesPosterior chamber phakic intraocular lensTomografía de coherencia ópticaLentes refractivas fáquicaslcsh:RE1-994Anatomical relationshipOriginal Articlesense organsDominio espectralPhakic Refractive Lens (PRL)businesslcsh:Optics. LightOptometryJournal of Optometry
researchProduct

The "sandwich technique" for iris-fixated phakic intraocular lens implantation.

2006

ABSTRACT PURPOSE: To describe a new technique of implantation of the Artisan/Verisyse phakic intraocular lens (PIOL). METHODS: After PIOL insertion into the anterior chamber, a bolus of a high viscosity ophthalmic viseosurgical device (OVD) is placed over the optic, separating it widely from the endothelium. RESULTS: The technique decreases the chance of endothelial damage during enclavation. CONCLUSIONS: A bolus of a high viscosity OVD placed on the anterior surface of the Artisan/Verisyse PIOL may make enclavation safer. [J Refract Surg. 2006;22:96-98.]

medicine.medical_specialtygenetic structuresbusiness.industryAnterior Chambermedicine.medical_treatmentSuture TechniquesIrisIntraocular lensAnterior surfacePhakic intraocular lensRefractive Surgical ProceduresOphthalmologyLens Implantation IntraocularOphthalmologymedicineHumansSurgerybusinessSandwich techniqueJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct

Artiflex Toric Phakic Intraocular Lens Implantation in Congenital Nystagmus

2011

Case: A 44-year-old woman with congenital nystagmus and myopic astigmatism in both eyes who was submitted to phakic intraocular lens (pIOL) implantation. Methods: Full ophthalmologic examination including refractive status, corrected (CDVA) and uncorrected (UCVA) monocular and binocular visual acuities, ocular motility, slit-lamp evaluation, tonometry and fundoscopy before and after implantation of toric pIOLs (Artiflex; Ophtec BV, The Netherlands) in both eyes. Results: Preoperative logMAR CDVA were 0.699 and 0.420 in the right and left eye, respectively. Three months after surgery, logMAR UCVA were 0.398 and 0.182, reaching binocular logMAR UCVA of 0.132. There were no changes in nystagmu…

medicine.medical_specialtygenetic structuresbusiness.industrymedicine.medical_treatmentToric phakic intraocular lensNystagmusPhakic intraocular lenseye diseasesMyopic astigmatismOphthalmologyLeft eyeNystagmuslcsh:OphthalmologyOphthalmologic examinationlcsh:RE1-994OphthalmologyRefractive surgeryMedicineIn patientPublished: August 2011sense organsmedicine.symptomRefractive surgerybusinessCongenital nystagmusCase Reports in Ophthalmology
researchProduct