Transit dose comparisons for60Co and192Ir HDR sources

2016

The goal of this study is to evaluate the ambient dose due to the transit of high dose rate (HDR) 60Co sources along a transfer tube as compared to 192Ir ones in a realistic clinical scenario. This goal is accomplished by evaluating air-kerma differences with Monte Carlo calculations using PENELOPE2011. Scatter from both the afterloader and the patient was not taken into account. Two sources, mHDR-v2 and Flexisource Co-60, (Elekta Brachytherapy, Veenendaal, the Netherlands) have been considered. These sources were simulated within a standard transfer tube located in an infinite air phantom. The movement of the source was included by displacing their positions along the connecting tube from …

PhysicsMedical staffmedicine.medical_treatmentBrachytherapyMonte Carlo methodPublic Health Environmental and Occupational HealthGeneral MedicineImaging phantom030218 nuclear medicine & medical imagingComputational physics03 medical and health sciences0302 clinical medicine030220 oncology & carcinogenesisTransfer (computing)medicineDose rateWaste Management and DisposalTransit (satellite)Clinical scenarioJournal of Radiological Protection
researchProduct

Quantum Stochastic Resonance in a Micromaser

1998

We demonstrate that quantum stochastic resonance allows for the noise-controlled synchronization of quantum jumps between the metastable states of the quantized radiation field in a micromaser. Under readily accessible experimental conditions optimal synchronization is achieved at a finite temperature $T\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}500\mathrm{mK}$ of the environment.

PhysicsMetastabilityQuantum mechanicsRadiation fieldQuantum electrodynamicsSynchronization (computer science)General Physics and AstronomyStochastic resonance (sensory neurobiology)QuantumImaging phantomPhysical Review Letters
researchProduct

Novel digital K-edge imaging system with transition radiation from an 855-MeV electron beam

2001

A novel K-edge imaging method has been developed at the Mainz Microtron MAMI aiming at a very efficient use of the transition radiation (TR) flux generated by the external 855-MeV electron beam in a foil stack. A fan-like quasi-monochromatic hard X-ray beam is produced from the /spl plusmn/1-mrad-wide TR cone with a highly oriented pyrolytic graphite (HOPG) crystal. The absorption of the object in front of a 30 mm/spl times/10 mm pn charge-coupled device (pn-CCD) photon detector is measured at every pixel by a broad-band energy scan around the K-absorption edge. This is accomplished by a synchronous variation of the lateral crystal position and the electron beam direction which defines also…

PhysicsNuclear and High Energy Physicsbusiness.industryDetectorchemistry.chemical_elementImaging phantomXenonOpticsNuclear Energy and EngineeringTransition radiationK-edgechemistryHighly oriented pyrolytic graphiteCathode rayElectrical and Electronic EngineeringbusinessMicrotronIEEE Transactions on Nuclear Science
researchProduct

Monte Carlo evaluation of the Filtered Back Projection method for image reconstruction in proton computed tomography

2011

Abstract In this paper the use of the Filtered Back Projection (FBP) Algorithm, in order to reconstruct tomographic images using the high energy (200–250 MeV) proton beams, is investigated. The algorithm has been studied in detail with a Monte Carlo approach and image quality has been analysed and compared with the total absorbed dose. A proton Computed Tomography (pCT) apparatus, developed by our group, has been fully simulated to exploit the power of the Geant4 Monte Carlo toolkit. From the simulation of the apparatus, a set of tomographic images of a test phantom has been reconstructed using the FBP at different absorbed dose values. The images have been evaluated in terms of homogeneity…

PhysicsNuclear and High Energy Physicsmedicine.medical_specialtyTomographic reconstructionRadon transformImage qualitybusiness.industryPhysics::Medical PhysicsMonte Carlo methodIterative reconstructionImaging phantomOpticsAbsorbed doseHomogeneity (physics)medicineMedical physicsbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

DOI measurement with monolithic scintillation crystals: A primary performance evaluation

2007

We report a first assessment of image quality enhancement achieved by the implementation of depth of interaction detection with monolithic crystals. The method of interaction depth measurement is based on analogue computation of the standard deviation with an enhanced charge divider readout. This technique of depth of interaction detection was developed in order to provide fast and determination of this parameter at a reasonable increase of detector cost. The detector consists of an large-sized monolithic scintillator coupled to a position sensitive photomultiplier tube. A special design feature is the flat-topped pyramidal shape of the crystal. This reduces image compression near the edges…

PhysicsPhotomultiplierOpticsPhysics::Instrumentation and DetectorsImage qualityPoint sourcebusiness.industryMeasured depthDetectorScintillatorbusinessImage resolutionImaging phantom2007 IEEE Nuclear Science Symposium Conference Record
researchProduct

SU-FF-T-15: Comparison of Various Monte Carlo Codes for Brachytherapy Source Dosimetry

2009

Purpose: Monte Carlo simulations are used for dosimetric evaluation of brachytherapysources. Various investigators had demonstrated good agreement between the measured and simulated data while some others have shown discrepancies between the two methods. These discrepancies were attributed to the errors in cross section data, differences in phantom and source geometry and composition. However, the exact causes of these differences have not yet fully explored. The goal of this project is to verify the differences among the widely available Monte Carlo codes for brachytherapysourcedosimetry.Material and method: These investigations are based on VariSource 192 Ir , Model VS2000, IsoAid Advanta…

PhysicsPhotonStatisticsMonte Carlo methodDynamic Monte Carlo methodDosimetryGeneral MedicineFunction (mathematics)Statistical fluctuationsAnisotropyImaging phantomComputational physicsMedical Physics
researchProduct

246. Analysis of signal-to-noise ratio for a 2-channels coil developed to enable transcranial Magnetic Resonance-guided Focused Ultrasound Surgery (t…

2018

Abstract Purpose In recent years trans-cranial Magnetic Resonance-guided Focused Ultrasound Surgery (tcMRgFUS) treatments have aroused large scientific and medical interest [1] . Usually, tcMRgFUS systems are integrated with 3 T systems which allow the use of the body RF coil for both real time imaging and MR-thermometry. At University Hospital of Palermo there is the world-first installation of a tcMRgFUS system integrated with a 1.5 T scanner. Here we present the characterization in terms of signal-to-noise ratio (SNR) of a dedicated RF coils suitably developed (by InSightec) to enable tcMRgFUS treatments with 1.5 T MR units. Methods and materials The focused ultrasound equipment (ExAblat…

PhysicsScannerExAblateBiophysicsGeneral Physics and AstronomyGeneral MedicineImaging phantom030218 nuclear medicine & medical imagingMagnetic resonance guided focused ultrasound surgery03 medical and health sciences0302 clinical medicineTransducerSignal-to-noise ratio (imaging)Electromagnetic coil030220 oncology & carcinogenesisRadiology Nuclear Medicine and imagingBiomedical engineeringRadiofrequency coilPhysica Medica
researchProduct

Next generation of the Albira small animal PET based on high density SiPM arrays

2015

A new design of the small animal PET Albira system which detectors are based on arrays of SiPMs and monolithic LYSO scintillator is presented here. The system is made out of 3 rings of 8 detectors each, resulting on an axial and transaxial FOVs of 148 and 80 mm, respectively. The scanner is thermally stabilized using air-cooling. Working temperatures around 22–25°C are reached with individual detector variations around 0.2°C minimizing dark count rates and gain drifts. One of the most significant improvements of the current system is the accurate photon impact determination within the crystal volume, specially its depth of interaction. This allows the calculation of the true line of respons…

PhysicsScannerPhotonOpticsSilicon photomultiplierbusiness.industryDetectorbusinessParallaxSensitivity (electronics)Image resolutionImaging phantom2015 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)
researchProduct

The AX-PET Concept: New Developments And Tomographic Imaging

2011

The Axial PET (AX-PET) concept proposes a novel detection geometry for PET, based on layers of long scintillating crystals axially aligned with the bore axis. Arrays of wavelength shifting (WLS) strips are placed orthogonally and underneath the crystal layers; both crystals and strips are individually readout by G-APDs. The axial coordinate is obtained from the WLS signals by means of a Center-of-Gravity method combined with a cluster algorithm. This design allows spatial resolution and sensitivity to be decoupled and thus simultaneously optimized. In this work we present the latest results obtained with the 2-module AX-PET scanner prototype, which consists of 6 radial layers of 8 LYSO crys…

PhysicsScannerTomographic reconstructionbusiness.industrySTRIPSIterative reconstructionImaging phantomLyso-law.inventionOpticsData acquisitionlawcount ratebusinessImage resolution
researchProduct

Optimal geometry for efficient loading of an optical dipole trap

2009

One important factor which determines efficiency of loading cold atoms into an optical dipole trap from a magneto-optical trap is the distance between the trap centers. By studying this efficiency for various optical trap depths (2--110 mK) we find that for optimum dipole trap loading, longitudinal displacements up to 15 mm are necessary. An explanation for this observation is presented and compared with other work and a simple analytical formula is derived for the optimum distance between the trap centers.

PhysicsTrap (computing)Condensed Matter::Quantum GasesDipoleWork (thermodynamics)Atomic Physics (physics.atom-ph)Magnetic trapFOS: Physical sciencesPhysics::Atomic PhysicsAtomic physicsAtomic and Molecular Physics and OpticsImaging phantomPhysics - Atomic Physics
researchProduct