Diagrammatic expansion for positive spectral functions beyond GW : Application to vertex corrections in the electron gas
2014
We present a diagrammatic approach to construct self-energy approximations within many-body perturbation theory with positive spectral properties. The method cures the problem of negative spectral functions which arises from a straightforward inclusion of vertex diagrams beyond the GW approximation. Our approach consists of a two-steps procedure: we first express the approximate many-body self-energy as a product of half-diagrams and then identify the minimal number of half-diagrams to add in order to form a perfect square. The resulting self-energy is an unconventional sum of self-energy diagrams in which the internal lines of half a diagram are time-ordered Green's functions whereas those…
Guided ultrasonic waves in long bones: modelling, experiment and in vivo application.
2002
Existing ultrasound devices for assessing the human tibia are based on detecting the first arriving signal, corresponding to a wave propagating at, or close to, the bulk longitudinal velocity in bone. However, human long bones are effectively irregular hollow tubes and should theoretically support the propagation of more complex guided modes similar to Lamb waves in plates. Guided waves are attractive because they propagate throughout the bone thickness and can potentially yield more information on bone material properties and architecture. In this study, Lamb wave theory and numerical simulations of wave propagation were used to gain insights into the expected behaviour of guided waves in …
Influence of pixel size on quantification of airway wall thickness in computed tomography.
2009
Objectives: The purpose of this study was to determine the point where a further decrease in voxel size does not result in better automatic quantification of the bronchial wall thickness by using 2 different assessment techniques. Materials and Methods: The results from the commonly used full-width-at-half-maximum (FWHM) principle and a new technique (integral-based method [IBM]) were compared for thin-section multidetector computed tomography (MDCT) data sets from an airway phantom containing 10 different tubular airway phantoms and in a human subsegmental bronchus in vivo. Correlation with the actual wall thickness and comparison of the wall thicknesses assessed for different voxel sizes …
Active contour algorithm with discriminant analysis for delineating tumors in positron emission tomography.
2019
Abstract In the context of cancer delineation using positron emission tomography datasets, we present an innovative approach which purpose is to tackle the real-time, three-dimensional segmentation task in a full, or at least nearly full automatized way. The approach comprises a preliminary initialization phase where the user highlights a region of interest around the cancer on just one slice of the tomographic dataset. The algorithm takes care of identifying an optimal and user-independent region of interest around the anomalous tissue and located on the slice containing the highest standardized uptake value so to start the successive segmentation task. The three-dimensional volume is then…
Image quality analysis of
2019
Background 44Sc has been increasingly investigated as a potential alternative to 68Ga in the development of tracers for positron emission tomography (PET). The lower mean positron energy of 44Sc (0.63 MeV) compared to 68Ga (0.83 MeV) can result in better spatial image resolutions. However, high-energy γ-rays (1157 keV) are emitted at high rates (99.9%) during 44Sc decay, which can reduce image quality. Therefore, we investigated the impact of these physical properties and performed an unbiased performance evaluation of 44Sc and 68Ga with different imaging phantoms (image quality phantom, Derenzo phantom, and three-rod phantom) on two preclinical PET scanners (Mediso nanoScan PET/MRI, Siemen…
Phantom iterates of continuous functions
1985
Evaluation of DR and CR digital mammography systems based on phantom and breast dosimetry.
2006
Digital mammography has been progressively introduced in screening centers, since recent evolution of CR and DR detectors. However, it is questionable which exposure conditions would be more suitable when these techniques are applied, in order to reduce the glandular breast doses, as they are related with induced carcinogenesis. Several exposures have been performed in CR and DR mammography units for comparing absorbed doses during quality control assessments and during screening, diagnosis and treatment. In the first case, the CIRS11A mammographic phantom has been used with standard exposure conditions (28 kV, AEC mode with blackening +0, 50:50 glandularity and 4.5 compressed breast thickn…
The modulation transfer function and signal-to-noise ratio of different digital filters: a technical approach.
2011
The aim of this study was to illustrate the influence of digital filters on the signal-to-noise ratio (SNR) and modulation transfer function (MTF) of digital images. The article will address image pre-processing that may be beneficial for the production of clinically useful digital radiographs with lower radiation dose.Three filters, an arithmetic mean filter, a median filter and a Gaussian filter (standard deviation (SD) = 0.4), with kernel sizes of 3 × 3 pixels and 5 × 5 pixels were tested. Synthetic images with exactly increasing amounts of Gaussian noise were created to gather linear regression of SNR before and after application of digital filters. Artificial stripe patterns with defin…
Monte Carlo dosimetric study of the medium dose rate CSM40 source
2013
Abstract The 137Cs medium dose rate (MDR) CSM40 source model (Eckert & Ziegler BEBIG, Germany) is in clinical use but no dosimetric dataset has been published. This study aims to obtain dosimetric data for the CSM40 source for its use in clinical practice as required by the American Association of Physicists in Medicine (AAPM) and the European Society for Radiotherapy and Oncology (ESTRO). Penelope2008 and Geant4 Monte Carlo codes were used to characterize this source dosimetrically. It was located in an unbounded water phantom with composition and mass density as recommended by AAPM and ESTRO. Due to the low photon energies of 137Cs, absorbed dose was approximated by collisional kerma. Add…
Determination of the irradiation field at the research reactor TRIGA Mainz for BNCT.
2009
For the application of the BNCT for the excorporal treatment of organs at the TRIGA Mainz, the basic characteristics of the radiation field in the thermal column as beam geometry, neutron and gamma ray energies, angular distributions, neutron flux, as well as absorbed gamma and neutron doses must be determined in a reproducible way. To determine the mixed irradiation field thermoluminescence detectors (TLD) made of CaF(2):Tm with a newly developed energy-compensation filter system and LiF:Mg,Ti materials with different (6)Li concentrations and different thicknesses as well as thin gold foils were used.