Search results for "phantom"

showing 10 items of 196 documents

Total Variation Regularization in Digital Breast Tomosynthesis

2013

We developed an iterative algebraic algorithm for the reconstruction of 3D volumes from limited-angle breast projection images. Algebraic reconstruction is accelerated using the graphics processing unit. We varied a total variation (TV)-norm parameter in order to verify the influence of TV regularization on the representation of small structures in the reconstructions. The Barzilai-Borwein algorithm is used to solve the inverse reconstruction problem. The quality of our reconstructions was evaluated with the Quart Mam/Digi Phantom, which features so-called Landolt ring structures to verify perceptibility limits. The evaluation of the reconstructions was done with an automatic LR detection a…

Computer scienceGraphics processing unitInverseDigital Breast TomosynthesisTotal variation denoisingSolverAlgebraic numberAlgorithmRegularization (mathematics)Imaging phantom
researchProduct

Partial volume correction for volume estimation of liver metastases and lymph nodes in CT scans using spatial subdivision

2010

In oncological therapy monitoring, the estimation of tumor growth from consecutive CT scans is an important aspect in deciding whether the given treatment is adequate for the patient. This can be done by measuring and comparing the volume of a lesion in the scans based on a segmentation. However, simply counting the voxels within the segmentation mask can lead to significant differences in the volume, if the lesion has been segmented slightly differently by various readers or in different scans, due to the limited spatial resolution of CT and due to partial volume effects. We present a novel algorithm for measuring the volume of liver metastases and lymph nodes which considers partial volum…

Computer sciencebusiness.industryPartial volumecomputer.software_genreImaging phantomLesionVoxelmedicineSegmentationmedicine.symptombusinessNuclear medicinecomputerImage resolutionSubdivisionVolume (compression)SPIE Proceedings
researchProduct

Automated detection of patient movement during a CBCT scan based on the projection data.

2015

Objectives To develop an automated procedure to detect patient motion on the projection images acquired during a cone beam computed tomography (CBCT) scan and to evaluate the method's feasibility on small real-world CBCT images in relation to visual assessment. Methods Based on optical flow theory, software was developed using the sequence of the projection images of a CBCT machine for automated detection of patient motion. Averaged acceleration vectors were used as measurement data and compared with visual assessment of the projection images displayed as video. Seventy-nine CBCT data sets (small field-of-view: 40 mm) from our patient database were selected in a sequential fashion and evalu…

Cone beam computed tomographyComputer scienceMovementOptical flowVideo RecordingSensitivity and SpecificityPathology and Forensic MedicineAccelerationSoftwareImaging Three-DimensionalHumansRadiology Nuclear Medicine and imagingDentistry (miscellaneous)Computer visionSensitivity (control systems)Projection (set theory)Pixelbusiness.industryPhantoms ImagingFrame (networking)Cone-Beam Computed TomographyFeasibility StudiesRadiographic Image Interpretation Computer-AssistedSurgeryArtificial intelligenceOral SurgerybusinessArtifactsAlgorithmsSoftwareOral surgery, oral medicine, oral pathology and oral radiology
researchProduct

Evaluation of lens absorbed dose with Cone Beam IGRT procedures

2015

The purpose of this work is to evaluate the absorbed dose to the eye lenses due to the cone beam computed tomography (CBCT) system used to accurately position the patient during head-and-neck image guided procedures. The on-board imaging (OBI) systems (v.1.5) of Clinac iX and TrueBeam (Varian) accelerators were used to evaluate the imparted dose to the eye lenses and some additional points of the head. All CBCT scans were acquired with the Standard-Dose Head protocol from Varian. Doses were measured using thermoluminescence dosimeters (TLDs) placed in an anthropomorphic phantom. TLDs were calibrated at the beam quality used to reduce their energy dependence. Average dose to the lens due to …

Cone beam computed tomographyDosimeterPhantoms Imagingbusiness.industryPublic Health Environmental and Occupational HealthTruebeamRadiotherapy DosageGeneral MedicineCone-Beam Computed Tomographyequipment and supplieslaw.inventionLens (optics)lawAbsorbed doseLens CrystallineThermoluminescent DosimetryMedicineThermoluminescent Dosimetrysense organsLaser beam qualitybusinessNuclear medicineHeadWaste Management and DisposalImage-guided radiation therapyJournal of Radiological Protection
researchProduct

On cone-beam computed tomography artifacts induced by titanium implants

2010

Objectives: To briefly review the mathematical background of beam-hardening artifacts in cone-beam computed tomography (CBCT)-reconstruction and to investigate geometrical properties relevant for these reconstruction errors. By means of simulated and experimental results, beam-hardening effects caused by titanium implants are evaluated. Materials and methods: The geometrical and physical properties of the acquisition process of the projections used for 3D reconstruction are investigated and their effects on the CBCT images in the presence of titanium implants are derived. Beam-hardening effects are computed for a simplified polychromatic situation (three energy subsets of 80 and 110 kV) and…

Cone beam computed tomographyMaterials sciencemedicine.diagnostic_testbusiness.industry3D reconstructionchemistry.chemical_elementComputed tomographyRodImaging phantomArtifact reductionchemistrymedicineImplantOral SurgeryNuclear medicinebusinessTitaniumClinical Oral Implants Research
researchProduct

Alignment of cone beam computed tomography data using intra-oral fiducial markers.

2009

This article illustrates a new method to align and merge two partially overlapping volumes each of them generated by cone beam computed tomography (CBCT). The aggregate volume covers a larger area of investigation and is determined by localizing one fixed LEGO brick in both of the primal volumes. Based on the LEGO brick an approximate registration of the volumes is determined. Afterwards we improve the transformation by minimizing the difference in overlapping space. In this paper we present a method which automates these two steps and provides an aligned volume.

Cone beam computed tomographyMouthRadiological and Ultrasound Technologybusiness.industryComputer sciencePhantoms ImagingHealth InformaticsRadiography Dental DigitalCone-Beam Computed TomographyComputer Graphics and Computer-Aided DesignComputer Science::Computers and SocietyOpticsJawIntra oralHumansRadiology Nuclear Medicine and imagingComputer visionComputer Vision and Pattern RecognitionArtificial intelligencebusinessFiducial markerMerge (version control)Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society
researchProduct

Radiation dose in non-dental cone beam CT applications: a systematic review.

2018

Background: Radiation-induced health risks are broadly questioned in the literature. As cone beam computed tomography (CBCT) is increasingly used in non-dental examinations, its effective dose needs to be known. This study aimed to review the published evidence on effective dose of non-dental CBCT for diagnostic use by focusing on dosimetry system used to estimate dose. Materials and methods: A systematic review of the literature was performed on 12 November 2017. All the literature up to this date was included. The PubMed and web of science databases were searched. Studies were screened for inclusion based on defined inclusion and exclusion criteria according to the preferred reporting ite…

Cone beam computed tomographyRadiology Nuclear Medicine and ImagingComputed tomography dose indexCone beam computed tomographyRadiation DosageEffective dose (radiation)Imaging phantom030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineMedicineDosimetryHumansSkeletal imagingEffective dosebusiness.industry030206 dentistryGeneral MedicineCone-Beam Computed TomographyParanasal sinusesmedicine.anatomical_structureDose area productInclusion and exclusion criteriabusinessNuclear medicineHeadNeckHead and neck imagingHumanLa Radiologia medica
researchProduct

9 Development of an experimental tool to evaluate normal tissue 3D doses in external-beam radiotherapy

2018

Introduction Recently, cancer treatment improvement enabled an increase in patients’ survival rate. In more than half of the cases, radiotherapy participates in the cure for cancer. The efficacy of this technique is well known but it inevitably delivers doses to normal tissues exposing them to radio-induced complications risks [1] . Moreover, the longer patients’ life expectancy increases the risk of developing long-term complications such as second cancers. Thus, evaluating the risks following cancer treatment involving radiotherapy constitutes a major challenge. In this context, an experimental tool has been developed to evaluate normal tissue doses delivered by the different radiotherapy…

Contouringbusiness.industrymedicine.medical_treatmentBiophysicsGeneral Physics and AstronomyDose profileContext (language use)General MedicineGel dosimetryImaging phantom030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinePlanned Dose030220 oncology & carcinogenesismedicineRadiology Nuclear Medicine and imagingExternal beam radiotherapyNuclear medicinebusinessRadiation treatment planningPhysica Medica
researchProduct

SU-FF-T-365: Practical Reconstruction Method for 3D CT-Based Brachytherapy with Shielded Colpostats

2006

Introduction and purpose.‐ The most extended worldwide HDR and PDR afterloading machines are from Nucletron, using the Plato Treatment Planning System (TPS) to perform the clinical dosimetry. The Fletcher‐Williamson (FW) vaginal colpostat applicators are widely used with these machines, they are made of a very dense material (densimet‐17) which allows shielding up to 50% of the dose. Almost all the TPS have incorporated the CT‐Based Brachytherapy (BT), in which the CT catheters and applicators reconstruction is based on contiguous CT transverse slices where the user points the catheter position. The problem with these applicators is the production of artefacts that makes the reconstruction …

Contouringmedicine.diagnostic_testComputer sciencebusiness.industrymedicine.medical_treatmentBrachytherapyComputed tomographyGeneral MedicineReconstruction methodImaging phantomlaw.inventionCatheterlawBreast implantShielded cablemedicineDosimetryClinical dosimetryRadiation treatment planningNuclear medicinebusinessMedical Physics
researchProduct

Contrast perception in digitized panoramic radiographs compared with their film-based origin

2002

Abstract Objectives. We sought to compare the visual image quality of film-based and digitized panoramic radiographs through use of a hole-containing test wedge. Study Design. An aluminum wedge containing 100 cells, of which 90 were given shallow holes, was exposed in the film-based Orthophos CD panoramic unit. Two radiographs subjectively exhibiting optimum contrast were selected. Films were digitized with a charge-coupled device flatbed scanner at 300 dpi. Films and digitized images were rated cellwise by 2 similar groups of 50 observers each with respect to spot perception. Results. The mean sensitivity was 0.26 ± 0.09 for film and 0.20 ± 0.07 for digitized images (P =.000), with a prono…

Contrast effectRadiographymedia_common.quotation_subjectContrast MediaSensitivity and SpecificityAbsorptiometry PhotonRadiography PanoramicHumansContrast (vision)MedicineGeneral DentistryDigital radiographymedia_commonObserver VariationPhantoms Imagingbusiness.industryX-Ray FilmReproducibility of ResultsRadiography Dental DigitalContrast perceptionOtorhinolaryngologyRadiographic Image Interpretation Computer-AssistedSurgeryOral SurgerybusinessNuclear medicineAnalog-Digital ConversionOral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology
researchProduct