Search results for "phase microextraction"

showing 10 items of 134 documents

Selective and sentivive method based on capillary liquid chromatography with in-tube solid phase microextraction for determination of monochloramine …

2015

Abstract Due to the difficulties of working with chloramines, a critical examination of monochloramine standard preparation has been performed in order to select the best synthesis conditions. The analyte has been determined by in-tube solid phase extraction coupled to capillary liquid chromatography with UV detection (IT-SPME Capillary LC DAD). Potential factors affecting the response of monochloramine such as the pH of mobile phase and the volume of sample processed by IT-SPME Capillary LC DAD have been investigated and optimized. According to the results of the study, 0.1 mL or 4.0 mL of sample at neutral pH were loaded in the chromatographic system. A sensitive and selective method has …

Detection limitReproducibilityAnalyteChloramineChromatographyCapillary actionChloraminesOrganic ChemistryAnalytical chemistryElectrophoresis CapillaryWaterGeneral MedicineSolid-phase microextractionBiochemistryAnalytical Chemistrychemistry.chemical_compoundLinear rangechemistryLimit of DetectionSolid phase extractionSolid Phase MicroextractionWater Pollutants ChemicalChromatography LiquidJournal of Chromatography A
researchProduct

Multimycotoxin LC-MS/MS Analysis in Tea Beverages after Dispersive Liquid-Liquid Microextraction (DLLME).

2017

The aim of the present study was to develop a multimycotoxin liquid chromatography tandem mass spectrometry (LC-MS/MS) method with a dispersive liquid-liquid microextraction procedure (DLLME) for the analysis of AFs, 3aDON, 15aDON, NIV, HT-2, T-2, ZEA, OTA, ENNs, and BEA in tea beverages and to evaluate their mycotoxin contents. The proposed method was characterized in terms of linearity, limits of detection (LODs), limits of quantification (LOQs), recoveries, repeatability (intraday precision), reproducibility (interday precision), and matrix effects to check suitability. The results show LODs in the range of 0.05-10 μg/L, LOQs in the range of 0.2-33 μg/L, and recoveries in the range of 65…

Detection limitReproducibilityChromatographyTeaChemistryLiquid Phase Microextraction010401 analytical chemistryFood Contamination04 agricultural and veterinary sciencesGeneral ChemistryRepeatabilityMycotoxinsGreen tea040401 food science01 natural sciences0104 chemical scienceschemistry.chemical_compound0404 agricultural biotechnologyLiquid chromatography–mass spectrometryLimit of DetectionTandem Mass SpectrometryLc ms msLiquid liquidGeneral Agricultural and Biological SciencesMycotoxinJournal of agricultural and food chemistry
researchProduct

Determination of the new psychoactive substance dichloropane in saliva by microextraction by packed sorbent – Ion mobility spectrometry

2018

Abstract A simple procedure based on microextraction by packed sorbent (MEPS) has been proposed for the extraction of dichloropane in oral fluids and its determination by ion mobility spectrometry (IMS). Extraction conditions such as type of sorbent (octyl and octadecyl silica), sample pH, number of sample loadings, and elution volume were evaluated to obtain the most appropriate values. Dichloropane was extracted from saliva samples using C8 MEPS, loading with 100 μL sample (adjusted to pH 7) in 4 cycles, washing with 100 μL deionized water, and eluting with 50 μL 2-propanol in 10 cycles. The proposed MEPS procedure has been validated in terms of linearity, accuracy, and precision. A limit…

Detection limitSalivaSorbentChromatographyChemistryIon-mobility spectrometryElution010401 analytical chemistryOrganic ChemistryExtraction (chemistry)General Medicine010402 general chemistryMass spectrometry01 natural sciencesBiochemistryGas Chromatography-Mass Spectrometry0104 chemical sciencesAnalytical ChemistryCocaineLimit of DetectionIon Mobility SpectrometryHumansGas chromatography–mass spectrometrySalivaSolid Phase MicroextractionJournal of Chromatography A
researchProduct

Development of stir bar sorptive-dispersive microextraction mediated by magnetic nanoparticles and its analytical application to the determination of…

2014

A novel microextraction technique combining the principles of stir bar sorptive extraction (SBSE) and dispersive micro-solid phase extraction (DμSPE) is presented. The main feature of the method is the use of a neodymium-core stirring bar physically coated with a hydrophobic magnetic nanosorbent. Depending on stirring speed, the magnetic sorbent either acts as a coating material to the stir bar, thus affording extraction alike SBSE, or as a dispersed nanosorbent medium for the collection and extraction of the target analytes, in close analogy to DμSPE. Once the stirring process is finished, the strong magnetic field of the stir bar prevails again and rapidly retrieves the dispersed MNPs. Al…

Detection limitSorbentChromatographyChemistryOsmolar ConcentrationOrganic ChemistryExtraction (chemistry)Reproducibility of ResultsWaterGeneral MedicineHydrogen-Ion Concentrationengineering.materialBiochemistryAnalytical ChemistryCoatingDesorptionPhase (matter)engineeringMagnetic nanoparticlesSurface modificationOrganic ChemicalsMagnetite NanoparticlesHydrophobic and Hydrophilic InteractionsSolid Phase MicroextractionJournal of Chromatography A
researchProduct

Determination of carbonyl compounds in particulate matter PM2.5 by in-tube solid-phase microextraction coupled to capillary liquid chromatography/mas…

2013

Abstract In this paper, a new procedure based on in-tube solid phase microextraction (IT-SPME)-capillary liquid chromatography hyphenated to mass spectrometry detection by using microelectrospray ionisation (CapLC–MS), has been reported. The device was proposed to quantify 12 carbonyl compounds (10 aliphatic aldehydes, an unsaturated aldehyde and a ketone) derivatized with 2,4-dinitrophenylhidrazine (DNPH) reagent in aqueous extracts of PM 2.5 . This methodology involves the on-line preconcentration of DNPH-carbonyl compounds derivatives coupled to the CapLC–MS system, efficiently providing appropriate sensitivity for the determination of the target analytes. Detection limits for the analyt…

Detection limitchemistry.chemical_classificationAnalyteAldehydesChromatographyKetoneAnalytical chemistryKetonesMass spectrometrySolid-phase microextractionAldehydeMass SpectrometryAnalytical ChemistryPhenylhydrazineschemistryLiquid chromatography–mass spectrometryLimit of DetectionReagentParticulate MatterSolid Phase MicroextractionWater Pollutants ChemicalChromatography LiquidTalanta
researchProduct

Comparative study of the determination of trimethylamine in water and air by combining liquid chromatography and solid-phase microextraction with on-…

2005

This work describes a new approach for the determination of trimethylamine (TMA) in water and air by liquid chromatography (LC). The assay is based on the employment of a solid-phase microextraction (SPME) fiber for sampling and for derivatization of the analyte with the fluorogenic reagent 9-fluorenylmethyl chloroformate (FMOC). The fiber, with a Carbowax-templated resin -50mum coating, was first immersed into a solution of the reagent. Once loaded with the reagent, the fiber was immersed into the water samples or exposed to the air samples in order to extract and to derivatize the analyte. Finally, the fiber was placed into a HPLC-SPME interface to desorb and transfer the TMA-FMOC derivat…

Detection limitchemistry.chemical_compoundAnalyteChromatographychemistryReagentAnalytical chemistryTrimethylamineFiberChloroformateSolid-phase microextractionDerivatizationAnalytical ChemistryTalanta
researchProduct

Multiresidue analysis of organic pollutants by in-tube solid phase microextraction coupled to ultra-high performance liquid chromatography-electrospr…

2013

In this work, in-tube solid phase microextraction (IT-SPME) coupling with ultra-high-pressure liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) multiresidue analytical method has been proposed for the first time for on-line enrichment of 9 analytes included in Water Frame Directive 2000/60/EC (WFD). The device was equipped with a GC TRB-5 capillary column, used as pre-concentration loop, and two conventional six-port injection valves. Water sample and desorption solvent volumes were tested. The optimum conditions were 4mL of processed sample followed by elution with 40μL of methanol. The analytes were detected with a mass spectrometer after being ionized positively using an elect…

ElectrosprayChromatographyChemistryElutionElectrospray ionizationOrganic ChemistryAnalytical chemistryPesticide ResiduesGeneral MedicineMass spectrometryTandem mass spectrometrySolid-phase microextractionBiochemistryAnalytical ChemistryLiquid chromatography–mass spectrometryTandem Mass SpectrometryDesorptionChromatography High Pressure LiquidSolid Phase MicroextractionWater Pollutants ChemicalJournal of chromatography. A
researchProduct

Analysis of carbamate and phenylurea pesticide residues in fruit juices by solid-phase microextraction and liquid chromatography–mass spectrometry

2007

A new analysis method to detect carbamates and phenylurea pesticide residues in fruit juices was developed using solid-phase microextraction (SPME) coupled with liquid chromatography-single quadrupole mass spectrometry (LC/MS) and liquid chromatography-quadrupole ion trap mass spectrometry (LC/QIT-MS). The pesticide residues present in watery matrices as fruit juices were extracted using three types of fibers: 50-microm Carbowax/templated resin (CW/TPR), 60-mum poly(dimethylsiloxane)/divinylbenzene (PDMS/DVB) and 85-microm polyacrylate. The different extraction conditions were evaluated choosing as the best parameters 90 min (time), 20 degrees C (temperature) and 1 ml (volume). After extrac…

ElectrosprayChromatographyChemistryPhenylurea CompoundsElectrospray ionizationOrganic ChemistrySelected reaction monitoringPesticide ResiduesGeneral MedicineSolid-phase microextractionMass spectrometryBiochemistryHigh-performance liquid chromatographyMass SpectrometryAnalytical ChemistryBeveragesLiquid chromatography–mass spectrometrySelected ion monitoringCarbamatesChromatography High Pressure LiquidJournal of Chromatography A
researchProduct

Removal and fate of endocrine disruptors chemicals under lab-scalepostreatment stage. Removal assessment using light, oxygen and microalgae

2013

[EN] The aim of this study was to assess the effect of light, oxygen and microalgae on micropollutants removal. The studied micropollutants were 4-(1,1,3,3-tetramethylbutyl)phenol (OP), technical-nonylphenol (t-NP), 4-n-nonylphenol (4-NP), Bisphenol-A (BPA). In order to study the effect of the three variables on the micropollutants removal, a factorial design was developed. The experiments were carried out in four batch reactors which treated the effluent of an anaerobic membrane bioreactor. The gas chromatography mass spectrometry was used for the measurement of the micropollutants. The results showed that light, oxygen and microalgae affected differently to the degradation ratios of each …

Environmental EngineeringAlkylphenolLightBioengineeringPortable water purificationEndocrine DisruptorsSolid-phase microextractionGas Chromatography-Mass SpectrometryWater PurificationLimit of DetectionMicroalgaeWaste Management and DisposalEffluentSolid Phase MicroextractionTECNOLOGIA DEL MEDIO AMBIENTERenewable Energy Sustainability and the EnvironmentChemistryRemoval endocrine disruptorsSorptionGeneral MedicineFactorial experimentOxygenBiodegradation EnvironmentalEnvironmental chemistryAdsorptionAerationGas chromatography–mass spectrometryWater Pollutants Chemical
researchProduct

Biological effects and photodegradation by TiO(2) of terpenes present in industrial wastewater.

2010

Abstract The aim of this work was to study the biological effects of four monoterpenes, i.e. α-pinene, β-pinene, 3-carene and d -limonene present in the wastewater of a citrus transformation factory. The study was carried out by exposing V79 Chinese hamster cells to single terpene or to the mixture of four terpenes at concentrations corresponding to those in the wastewater evaluated by head space solid phase micro extraction and gas chromatography (HS-SPME-GC) analyses. Treatments with single or combined terpenes similarly affected cell vitality, but only the combined treatments induced the 6-thioguanine resistant mutants. Moreover the photocatalytic degradation of the four terpenes was suc…

Environmental EngineeringChromatography GasSettore CHIM/10 - Chimica Degli AlimentiHealth Toxicology and MutagenesisIndustrial WasteCatalysisCell LineTerpeneIndustrial wastewater treatmentchemistry.chemical_compoundCricetulusCricetinaeEnvironmental ChemistryAnimalsWater PollutantsPhotodegradationWaste Management and DisposalEffluentSolid Phase MicroextractionTitaniumLimoneneChromatographyPhotolysisTerpenesTerpenes clonogenicassay Terpenes mutationassay TiO2 photocatalysisPollutionSettore BIO/18 - GeneticaWastewaterchemistryEnvironmental chemistryPhotocatalysisSettore CHIM/07 - Fondamenti Chimici Delle TecnologieGas chromatographyJournal of hazardous materials
researchProduct