Changes in anterior chamber eye during accommodation as assessed using a Dual Scheimpflug system
2014
Purpose: To study the changes in anterior chamber depth (ACD), anterior chamber angle (ACA), and pupil diameter (PD) during accommodation. Methods: Eighty eyes of 80 subjects, aged 22 to 40 years, were included. The rotating Dual Scheimpflug and a Placido disc system (Galilei G4, Ziemer Ophthalmic Systems AG, Switzerland) was used to measure the changes in ACD, ACA, and PD during accommodation. ACD measurement was taken for the central zone and for 4 more positions, each in different orientation (nasal, superior, temporal and inferior), 4 mm away from the centre. ACA was measured for the whole eye as well for the nasal, superior, temporal, and inferior quadrants. These metrics were obtained…
Scheimpflug biometry of the anterior segment after implantation of foldable iris-fixated lenses.
2006
ABSTRACT PURPOSE: To evaluate intraocular dimensions of the anterior segment of myopic phakic eyes after implantation of foldable iris-fixated lenses. METHODS: Seventeen myopic eyes that received a foldable iris-fixated phakic intraocular lens (PIOL) were assessed. Distances between the cornea and the IOLoptic edge and between the IOL optic and the crystalline lens were evaluated using Scheimpf lug photography 3 months postoperatively. RESULTS: The average postoperative distance between the central corneal endothelium and the anterior surface of the IOL was 2.01±0.26 mm. The distance between the corneal endothelium and the peripheral edge of the IOL averaged 1.32±0.18 mm at the 12 o'clock p…
Changes in the anterior chamber during accommodation assessed with a Scheimpflug system.
2014
Purpose To study changes in the anterior chamber depth (ACD), anterior chamber angle, and pupil diameter with accommodation. Setting University of Valencia, Valencia, Spain. Design Evaluation of diagnostic technology. Methods A rotating Scheimpflug camera (Pentacam HR) was used to measure changes in the ACD, anterior chamber angle, and pupil diameter with accommodation. Peripheral ACD was measured at the corneal center and 2.0 mm away from it in the nasal, superior, temporal, and inferior directions. The anterior chamber angle was computed as the mean anterior chamber angle of the entire eye. All measurements were obtained with accommodation stimuli ranging from +1.0 to −4.0 diopters (D) in…
OCT is not useful for detection of minimal diabetic retinopathy in type 1 diabetes.
2009
Optical coherence tomography (OCT) has been proven useful in measuring retinal thickness (RT) in patients with diabetes, although with discordant results in different studies. We examined RT in patients with type 1 diabetes (T1D) with or without minimal diabetic retinopathy (MDR) to test whether OCT is able to identify early retinal changes and potential correlations with metabolic parameters. RT of 102 patients with T1D (53 females, 49 males, aged 27.03 +/- 7.4 years) and of 42 healthy controls was examined, with analysis of nine different sectors (fovea, four pericentral and four peripheral sectors). According to the results of basal fundus photography, patients were divided into two grou…
A retinal snap shot may indicate individual risk for cardiovascular disease — The MIPH Eye&Health Study
2014
Examination of retinal vasculature can be used to non-invasively quantify changes within the microvasculature of the human body and might be a predictor of cardiovascular disease. This study evaluates associations of the structure of the retinal vasculature with established risk factors for cardiovascular disease.A cross-sectional study was performed in a working age population. Several systemic cardiovascular parameters were analyzed and PROCAM- and SCORE-risk estimates were calculated. A quantitative ophthalmological examination including digital fundus imaging has taken place. Central retinal arterial/venous equivalents (CRAE/CRVE) and arterio-venous ratio (AVR) were analyzed using valid…
Semi-automated retinal vessel analysis in nonmydriatic fundus photography.
2013
Purpose Funduscopic assessment of the retinal vessels may be used to assess the health status of microcirculation and as a component in the evaluation of cardiovascular risk factors. Typically, the evaluation is restricted to morphological appreciation without strict quantification. Our purpose was to develop and validate a software tool for semi-automated quantitative analysis of retinal vasculature in nonmydriatic fundus photography. Methods matlab software was used to develop a semi-automated image recognition and analysis tool for the determination of the arterial–venous (A/V) ratio in the central vessel equivalent on 45° digital fundus photographs. Validity and reproducibility of the r…
Retinal Imaging through Phakic Iris-Claw IOL.
2014
AbstractBackground: Phakic anterior chamber iris-fixated IOL (PIOL) are established for the correction of high myopia. These patients require attention to macular pathologies. This study was to evaluate the quality of imaging through the PIOLs. Methods: 54 eyes of 31 myopic and hyperopic patients with Verisyse®, Verisyse toric®, and Veriflex® phakic iris-fixated IOL were included. Mean preoperative refraction was −11.0 D and +5.7 D, respectively; mean follow-up time was 7.4 years (5–11 years). A matched control group was formed without PIOL implantation. OCT scans were performed and evaluated qualitatively and quantitatively. Results: In 52 eyes of 31 patients (96%), a 3D-OCT image and fund…
Prevalence of myopic maculopathy in the German population: results from the Gutenberg health study.
2019
AimsTo determine the prevalence of myopic maculopathy in the general population in Germany and to analyse potential associations with ocular and systemic factors.DesignThe Gutenberg Health Study is a population-based study, including 15 010 participants aged 35–74 years.MethodsMyopic maculopathy was graded in phakic eyes with spherical equivalent ≤−6 D by assessing fundus photographs according to a recent international photographic classification system (META-PM). 801 eyes of 519 participants (mean age 51.0±0.77 years) met the conditions and had gradable fundus photographs. Age-specific prevalence estimates were computed. Multivariable logistic regression analysis was used to assess associa…
Clinical performance of the Nevisense system in cutaneous melanoma detection: an international, multicentre, prospective and blinded clinical trial o…
2014
Summary Background Even though progress has been made, the detection of melanoma still poses a challenge. In light of this situation, the Nevisense electrical impedance spectroscopy (EIS) system (SciBase AB, Stockholm, Sweden) was designed and shown to have the potential to be used as an adjunct diagnostic tool for melanoma detection. Objectives To assess the effectiveness and safety of the Nevisense system in the distinction of benign lesions of the skin from melanoma with electrical impedance spectroscopy. Methods This multicentre, prospective, and blinded clinical study was conducted at five American and 17 European investigational sites. All eligible skin lesions in the study were exami…
Correlations between central corneal thickness and general anthropometric characteristics and cardiovascular parameters in a large European cohort fr…
2014
PURPOSE The aim of this study was to evaluate the correlations between general anthropometric features and cardiovascular parameters and central corneal thickness (CCT) in an adult European cohort. METHODS Analysis was based on a Gutenberg Health Study cohort that included 5000 subjects (2540 male, 2460 female), aged 35 to 74 years at enrollment. The participants underwent a standardized protocol with a comprehensive questionnaire; ophthalmic examination (slit-lamp biomicroscopy; autorefractometry; noncontact tonometry; fundus photography; CCT measurements (optical pachymetry); visual field testing; and a thorough general examination focused on cardiovascular parameters, psychosomatic evalu…