Search results for "photopic vision"
showing 10 items of 55 documents
Visual function comparison of 2 aspheric multifocal intraocular lenses
2011
To compare visual function after bilateral implantation of the multifocal Lentis Mplus LS-312 with a nonrotational symmetrical design (copolymer aspheric) or the Acrysof Restor SN6AD1 +3.0 D (hybrid aspheric) intraocular lens (IOL).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Comparative case series.Six months postoperatively, corrected distance visual acuity (CDVA), distance-corrected near visual acuity (DCNVA), the defocus curve, and photopic and mesopic contrast sensitivity with and without glare were measured.The mean CDVA was 0.02 ± 0.06 (SD) with the copolymer aspheric IOL and -0.06 ± 0.05 logMAR with the hybrid aspheric IOL (P=.07) and the mean DCNVA, 0.10 ± 0.06 and -0.0…
Visual performance comparison between contact lens-based pinhole and simultaneous vision contact lenses.
2011
Background The aim was to evaluate the visual performance provided with a contact lens-based pinhole design against a simultaneous vision multifocal contact lens. Methods In a cross-over study at the University of Valencia, 22 presbyopic patients were evaluated using an artificial pupil fitted on the non-dominant eye and the simultaneous vision PureVision Multifocal contact lenses. After one month of contact lens wear, binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance contrast sensitivity, binocular near contrast sensitivity, and stereoacuity were measured, under photopic conditions (85 cd/m2). In addition, binocular distance vis…
Artificial pupil versus contralateral balanced contact lens fit for presbyopia correction.
2014
Purpose: To assess and compare the effects of contact lens-based artificial pupil design and contralateral balanced multifocal contact lens combination (CBMCLC) on visual performance. Methods: This randomized crossover study conducted at the University of Valencia, Spain included 38 presbyopic patients using an artificial pupil contact lens in the nondominant eye and a CBMCLC. After a month of lens wear, the binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance, and near contrast sensitivity and near stereoacuity (NSA) were measured under photopic conditions (85 cd/m2). Moreover, BDVA and binocular distance contrast sensitivity were …
Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens
2007
To determine whether pupil size is correlated with visual acuity and contrast sensitivity at all distances in eyes with an apodized diffractive intraocular lens (IOL).Private Clinic, Oviedo, Spain.Six months after surgery, the best corrected distance visual acuity, best distance-corrected near visual acuity, intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m2) and mesopic (5 cd/m2) conditions were measured in 670 eyes of 335 consecutive patients who had implantation of the AcrySof ReSTOR Natural IOL (SN60D3, Alcon). Pupil diameters in distance vision were measured using a pupillometer.The logMAR best corrected distance acuity was significantly better with …
Bilateral implantation of the Acri.LISA bifocal intraocular lens in myopic eyes.
2009
Purpose To asses visual quality after bilateral implantation of the Acri.LISA 366D intraocular lens (IOL) (Carl Zeiss Meditec) in patients with high and low–moderate myopia. Methods A total of 304 eyes of 152 patients had bilateral implantation of the Acri.LISA 366D IOL. The patients were divided into 2 groups: low–moderate myopia (IOL power from 15 to 20.5 D) and high myopia (IOL power from 0 to 14.5 D). Monocular and binocular best-corrected distance visual acuity (BCVA) and best distance-corrected near visual acuity (BCNVA), binocular best distance-corrected intermediate visual acuity (BCIVA), and distance contrast sensitivity (OS) under photopic (85 cd/m2) and mesopic (5 cd/m2) conditio…
Contrast sensitivity after refractive lens exchange with a multifocal diffractive aspheric intraocular lens
2013
Purpose: To evaluate distance and near contrast sensitivity (CS) under photopic and mesopic conditions before and after refractive lens exchange (RLE) and implantation of the aspheric AcrySof ReSTOR (SN6AD3 model) intraocular lens (IOL) Methods: Sixty eyes of 30 consecutive patients after RLE underwent bilateral implantation with the aspheric AcrySof ReSTOR IOL. The patients sample was divided into myopic [n=15, mean spherical equivalent (SE) -6.87± 2.03 diopters (D)] and hyperopic (n=15, mean SE +4.52±1.14 D) groups. Monocular uncorrected visual acuity at distance and near (UCVA and UCNVA, respectively) and monocular best corrected visual acuity at distance and near (BCVA and BCNVA, respec…
Prospective visual evaluation of apodized diffractive intraocular lenses
2006
To evaluate distance, intermediate, and near visual performance in patients who had multifocal apodized diffractive intraocular lens (IOL) implantation.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.The best corrected distance visual acuity, best distance-corrected near visual acuity, intermediate visual acuity, distance contrast sensitivity under photopic and mesopic conditions, and patient satisfaction were measured in 325 patients and 335 patients who had bilateral implantation of the model SA60D3 IOL (AcrySof ReSTOR, Alcon) and model SN60D3 IOL (AcrySof Natural ReSTOR), respectively.At the 6-month postoperative visit, binocular best corrected distance acuity with the ReSTOR IO…
Prospective study of the Acri.LISA bifocal intraocular lens
2007
To assess the visual results after bilateral implantation of the bifocal Acri.LISA 366D intraocular lens (IOL) (Acri.Tec AG).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Eighty-one patients had bilateral implantation of the distance-dominant bifocal Acri.LISA 366D IOL in a prospective study. Monocular and binocular best corrected distance visual acuity and best distance-corrected near visual acuity, binocular best distance-corrected intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were determined.At the 3-month postoperative visit, the mean binocular best corrected distance acuity was 0.048 +/- 0.111 log…
Pupil size differences between female and male patients after cataract surgery.
2022
Purpose To evaluate the changes in pupil diameter in women and men after cataract surgery. The correlation of pupillary changes with the variables age and anterior chamber depth will be analyzed. Methods The values of 109 randomized eyes who underwent cataract surgery were obtained and divided into two groups, 71 women and 38 men. Pupil diameter was measured preoperatively and 3-months postoperatively using the pupillometer software of the Topolyzer Vario (Wavelight Laser Technologie AG). Anterior chamber depth was obtained with Pentacam® (Oculus). Differences in pupillary diameters were investigated and correlations with age and anterior chamber depth were analyzed. Results For mesopic pup…
Lack of effect of intraocular lens asphericity on visual performance with acrylic intraocular lenses.
2011
Purpose. To determine whether implantation of acrylic intraocular lens (IOL) with aspheric design (Tecnis Z9003, AMO) results in improved visual acuity or contrast sensitivity compared with conventional spherical acrylic IOL (AR40e, AMO). Methods. In an intraindividual randomized prospective study of 60 patients with bilateral cataract, the Tecnis Z9003 IOL was compared with the AR40e IOL. Ocular aberrations for a 4.0-mm pupil and 6.0-mm pupil were measured with a Hartmann-Shack aberrometer. Quality of vision was measured using visual acuity and contrast sensitivity under mesopic and photopic conditions. Results. Eyes with the Tecnis Z9003 IOL had significantly less spherical aberration and…