Search results for "photopic vision"

showing 10 items of 55 documents

Effect of sport-tinted contact lenses for contrast enhancement on retinal straylight measurements

2008

PURPOSE: To investigate the effect of two tinted contact lenses (CL) designed for outdoor sports activity on the psychometric determination of retinal straylight using the compensation comparison method. METHODS: Thirteen emmetropic subjects were randomly fitted with two different tinted Nike Maxsight (Bausch & Lomb, Rochester, NY, USA) CL in one eye, while the contralateral eye was fitted with a clear lens made of the same material (Optima 38, Bausch & Lomb). Three valid straylight measurements were taken on each eye before and a few minutes after lens insertion, when lens stabilization had occurred. RESULTS: The subjects' mean straylight values were 0.90 +/- 0.09 at baseline and 0.95 +/- …

Maleretinal straylightgenetic structuresPolymaconEmmetropiatinted lenslaw.inventionSports Equipmentchemistry.chemical_compound0302 clinical medicinelawScattering RadiationContrast (vision)media_commonSpectral filtersVision TestsEquipment DesignSensory SystemsLens (optics)Regression AnalysisFemalePhotopic visionAdultmedicine.medical_specialtyPsychometricsContact Lensescontact lensmedia_common.quotation_subjectLight scatterColorRetinaStatistics NonparametricContrast Sensitivity03 medical and health sciencesTinte contact lensOcular straylightOphthalmologymedicineHumansOcular straylightElectronic Data ProcessingScience & TechnologyRetinalContact lensOphthalmologyocular scatterchemistrypolymacon030221 ophthalmology & optometryOptometry030217 neurology & neurosurgeryOptometryOphthalmic and Physiological Optics
researchProduct

Correlation between optics quality of multifocal intraocular lenses and visual acuity

2009

Purpose To study the relationship between the optics quality of multifocal intraocular lenses (IOLs) and distance-corrected near, intermediate, and distance visual acuity to determine the degree to which optics quality must change to produce a significant difference in visual acuity. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods Monocular distance-corrected visual acuity (decimal and logMAR) was measured at 4 m, 70 cm, and 30 cm under photopic and mesopic conditions in eyes with 1 of 3 multifocal IOL models. Visual acuity versus the “average modulation” of the IOL was assessed. Results The pupil diameter and patient age were similar between the 3 IOL groups (20 …

Optics and Photonicsmedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresMesopic visionColor visionmedicine.medical_treatmentVisual AcuityIntraocular lensPupilOpticsLens Implantation IntraocularOphthalmologymedicineHumansAgedRetrospective StudiesLenses IntraocularPhacoemulsificationColor VisionFourier Analysisbusiness.industryPupilPhacoemulsificationMultifocal intraocular lenseye diseasesSensory SystemsOphthalmologyOptometrySurgerysense organsmedicine.symptombusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Transient reduction of the ocular perfusion pressure and the oscillatory potentials of the ERG

2005

Abstract Purpose. To evaluate the changes of the Oscillatory Potentials (OPs) of Electroretinogram (ERG) caused by short-term hypertension in human subjects, and their relationship with ocular perfusion pressure (OPP). Methods. Suction cup technique in 12 normal volunteers with OPs simultaneously recording. Results. Scotopic and photopic OPs were altered during OPP drop. Scotopic OPs showed more sensitiveness, with higher reduction (from 21% to 47%), when compared to the basal value, than in photopic recordings (from 14% to 34%). In both conditions, the relationship between OPP and OPs presented a steady amplitude before the trough after the +30 step, and rapid recovery after OPP normalisat…

Pressure testAdultMaleIntraocular pressuremedicine.medical_specialtyOcular hypertensionchemistry.chemical_compoundOpticsOphthalmologyElectroretinographymedicineHomeostasisHumansScotopic visionOscillatory potentialIntraocular Pressuremedicine.diagnostic_testbusiness.industryRetinal VesselsRetinalElectroretinogrammedicine.diseaseSensory SystemsOcular perfusion pressureOphthalmologyElectrophysiologychemistryRegional Blood FlowFemaleOcular Hypertensionsense organsbusinessErgElectroretinographyPhotopic visionVision Research
researchProduct

Short-Term Changes in Light Distortion in Orthokeratology Subjects

2015

Purpose. Quantifying adaptation to light distortion of subjects undergoing orthokeratology (OK) for myopia during the first month of treatment. Methods. Twenty-nine healthy volunteers (age: 22.34 ± 8.08 years) with mean spherical equivalent refractive error −2.10 ± 0.93D were evaluated at baseline and days 1, 7, 15, and 30 of OK treatment. Light distortion was determined using an experimental prototype. Corneal aberrations were derived from corneal topography for different pupil sizes. Contrast sensitivity function (CSF) was analyzed for frequencies of 1.50, 2.12, 3.00, 4.24, 6.00, 8.49, 12.00, 16.97, and 24.00 cpd under photopic conditions. Results. Average monocular values of all light di…

Refractive errormedicine.medical_specialtyArticle Subjectgenetic structuresmedia_common.quotation_subjectmedicine.medical_treatmentLentes de contactolcsh:Medicine01 natural sciencesGeneral Biochemistry Genetics and Molecular BiologyPupil010309 optics03 medical and health sciences0302 clinical medicineDistortionCorneaOphthalmology0103 physical sciencesMedicineContrast (vision)media_commonÓpticaScience & TechnologyGeneral Immunology and Microbiologymedicine.diagnostic_testbusiness.industrylcsh:ROrthokeratologyGeneral Medicinemedicine.diseaseCorneal topographyeye diseasesmedicine.anatomical_structure030221 ophthalmology & optometrysense organsbusinessPhotopic visionResearch ArticleBioMed Research International
researchProduct

Corneal Aberrations, Contrast Sensitivity, and Light Distortion in Orthokeratology Patients: 1-Year Results.

2016

Purpose. To evaluate the corneal higher-order aberrations (HOA), contrast sensitivity function (CSF), and light distortion (LD) in patients undergoing orthokeratology (OK). Methods. Twenty healthy subjects (mean age: 21.40 ± 8 years) with mean spherical equivalent refractive error M = −2.19 ± 0.97 D were evaluated at 1 day, 1 month, and 1 year after starting OK treatment. Monocular LD, photopic monocular CSF, and corneal HOA for 6 mm pupil size were measured. Results. LD showed an increase after the first night (𝑝 0.05). Spherical-like, coma-like, and secondary astigmatism HOA RMS increased significantly (𝑝 ≤ 0.022) from baseline to 1-month visit, remaining unchanged over the follow-up. C…

Refractive errormedicine.medical_specialtyArticle Subjectgenetic structuresmedicine.medical_treatmentmedia_common.quotation_subjectSpherical equivalent01 natural sciences010309 optics03 medical and health sciences0302 clinical medicinelcsh:OphthalmologyOphthalmology0103 physical sciencesmedicineContrast (vision)In patientmedia_commonScience & Technologybusiness.industryOrthokeratologyPupil sizeHealthy subjectsmedicine.diseaseOphthalmologylcsh:RE1-994030221 ophthalmology & optometryOptometrybusinessPhotopic visionResearch ArticleJournal of ophthalmology
researchProduct

A novel murine model of aging of the human retina

2008

Purpose Accumulation of lipids, and especially of cholesteryl esters, under the retinal pigment epithelium and within Bruch’s membrane is a normal feature of aging and has also been observed in human eyes with age-related maculopathy. Our objective was to evaluate the retinal phenotype of apoB100,LDLR-/- mice, a model for lipid metabolism dysfunction and potentially of aging of the retina. Methods ApoB100,LDLR-/- mice were studied at 7 and 14 months of age by standard scotopic and photopic electroretinography by comparison to control animals. Fundus images were obtained with a confocal SLO (Heidelberg Retina Angiograph). The integrity of the vascular system was investigated by means of fluo…

Retinamedicine.medical_specialtyRetinal pigment epitheliumgenetic structuresLipid metabolismRetinalGeneral MedicineAnatomyFundus (eye)Biologymedicine.diseaseeye diseasesOphthalmologychemistry.chemical_compoundmedicine.anatomical_structurechemistryOphthalmologymedicineMaculopathylipids (amino acids peptides and proteins)sense organsScotopic visionPhotopic visionActa Ophthalmologica
researchProduct

PRCD is concentrated at the base of photoreceptor outer segments and is involved in outer segment disc formation.

2019

Abstract Mutations of the PRCD gene are associated with rod-cone degeneration in both dogs and humans. Prcd is expressed in the mouse eye as early as embryonic day 14. In the adult mouse retina PRCD is expressed in the outer segments of both rod and cone photoreceptors. Immunoelectron microscopy revealed that PRCD is located at the outer segment rim, and that it is highly concentrated at the base of the outer segment. Prcd-knockout mice present with progressive retinal degeneration, starting at 20 weeks of age and onwards. This process is reflected by a significant and progressive reduction of both scotopic and photopic electroretinographic responses, and by thinning of the retina, and spec…

Retinal degenerationMalegenetic structuresImmunoelectron microscopyRetinal Pigment EpitheliumBiologyRetinachemistry.chemical_compoundMicePhagocytosisGeneticsmedicineAnimalsScotopic visionOuter nuclear layerEye ProteinsMolecular BiologyGenetics (clinical)Mice KnockoutRetinaRetinal DegenerationMembrane ProteinsRetinalGeneral Medicinemedicine.diseaseRod Cell Outer SegmentPhotoreceptor outer segmenteye diseasesCell biologyMice Inbred C57BLmedicine.anatomical_structurechemistryRetinal Cone Photoreceptor CellsFemalesense organsCone-Rod DystrophiesRetinitis PigmentosaPhotopic visionSignal TransductionHuman molecular genetics
researchProduct

Analysis of the possible benefits of aspheric intraocular lenses: review of the literature.

2008

We reviewed recently published studies that analyzed the visual and optical quality in eyes with different spherical and aspheric intraocular lenses (IOLs). Recent studies focused on visual quality metrics, such as visual acuity and contrast sensitivity, under photopic and mesopic lighting conditions and optical metrics, such as wavefront aberrations, especially spherical aberration. The results in this review were used in an attempt to understand whether there is a visual and/or optical benefit of implanting aspheric IOLs over implanting spherical IOLs.

Visual acuitygenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentVisual AcuityIntraocular lensProsthesis DesignContrast SensitivityOpticsLens Implantation IntraocularMedicineContrast (vision)Humansmedia_commonWavefrontLenses Intraocularbusiness.industryeye diseasesSensory SystemsOphthalmologySpherical aberrationIntraocular lensesOptometrySurgerysense organsmedicine.symptombusinessPhotopic visionJournal of cataract and refractive surgery
researchProduct

Visual performance with multifocal intraocular lenses

2004

Abstract Objective To evaluate distance and near visual performance under bright (photopic) and dim (mesopic) conditions in patients who had undergone uncomplicated cataract extraction with multifocal or monofocal intraocular lens (IOL) implantation. Design Prospective, nonrandomized, masked, comparative, observational case series. Participants Thirty-two eyes of 32 patients after zonal-progressive multifocal IOL implantation (Allergan Medical Optics Array SA-40N) and 32 eyes of 32 age-matched patients after monofocal IOL implantation (Allergan Medical Optics SI-40NB). Intervention All eyes underwent phacoemulsification and IOL implantation. Main outcome measures At 18 months after surgery,…

Visual acuitygenetic structuresbusiness.industryMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectIntraocular lensPhacoemulsificationMultifocal intraocular lenseye diseasesOphthalmologymedicineOptometryContrast (vision)sense organsSpatial frequencymedicine.symptombusinessPhotopic visionmedia_commonOphthalmology
researchProduct

Effect of the color of the intraocular lens on optical and visual quality

2014

Purpose: To analyze the optical quality of intraocular lenses (IOL) with an orange (PC440Y) and a yellow (SN60AT) filter, and correlate these results with the visual quality of patients with these implants. Setting: Fisabio Oftalmología Médica, Valencia, Spain. Design: Randomized prospective study. Materials and Methods: The IOL optical quality was determined using the modulation transfer function (MTF) and the spectral transmission. The visual quality of 87 eyes with cataract (51 with orange filter and 36 with yellow filter) was determined by best corrected visual acuity (BCVA) and contrast sensitivity function (CSF) under photopic and mesopic conditions. To analyze the results, we use a S…

choroidal thicknessmedicine.medical_specialtyVisual acuityrecurrenceorangegenetic structuresvisual acuityMesopic visionmedicine.medical_treatmentcontrast sensitivity functionIntraocular lensOrange (colour)Cataractsurgerylcsh:OphthalmologyOptical transfer functionOphthalmologymedicinescanning laser polarimetryfilterbusiness.industryChoroidenhanced depth imagingBoth lensesretinal nerve fiber layereye diseasesyellowOphthalmologyglaucomaIntraocular lensesFixed corneal compensationlcsh:RE1-994OptometryExotropiaOriginal Articlesense organsmedicine.symptombusinessPhotopic visionIndian Journal of Ophthalmology
researchProduct