Search results for "physics.ins-det"
showing 10 items of 505 documents
Plastic Scintillation Detectors for Time-of-Flight Mass Measurements
2020
Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting Cyclotron Laboratory (NSCL) by increasing the number of photomultiplier tubes that read out their light signals to four per detector, and characterized them in a test experiment with $^{48}$Ca beam at the NSCL. The new detectors achieved a time resolution ($\sigma$) of 7.5 ps. We systematically investigated different factors that affect their timing performance. In addition, we evaluated the ability of positioning the hitting points on the scintillator using the …
A scintillator based time-of-flight hodoscope with a new type of emitter follower divider
2004
A high precision, time-of-flight hodoscope has been constructed to analyse the secondary pion beam at GSI, Darmstadt. The hodoscope comprises three scintillator planes with the individual scintillator rods read out by photomultipliers in both ends. A new active base of the emitter follower type has been developed for stabilization of voltages at the last dynodes of the photomultiplier. The time resolution of this system was found to be sigma less than or equal to 150 ps for counting rates up to 2 MHz.
The Crystal Barrel spectrometer at LEAR
1992
The crystal Barrel spectrometer used at LEAR, CERN to study the products of pd annihilations is described. A 1380 element array of Csl crystals measures photons from the decay of π0, η, η′ and ω mesons. A segmented drift chamber in a 1.5T magnetic field is used to identify and measure charged particles. A fast on-line trigger on charged and neutral multiplicities and on the invariant mass of secondary particles is available. The performance of the detector is discussed.
Performance of production modules of the Belle II pixel detector in a high-energy particle beam
2021
The Belle II experiment at the Super B factory SuperKEKB, an asymmetric $e^+e^-$ collider located in Tsukuba, Japan, is tailored to perform precision B physics measurements. The centre of mass energy of the collisions is equal to the rest mass of the $\Upsilon(4S)$ resonance of $m_{\Upsilon(4S)} = 10.58\,\rm GeV$. A high vertex resolution is essential for measuring the decay vertices of B mesons. Typical momenta of the decay products are ranging from a few tens of MeV to a few GeV and multiple scattering has a significant impact on the vertex resolution. The VerteX Detector (VXD) for Belle II is therefore designed to have as little material as possible inside the acceptance region. Especial…
Determining the neutrino mass with cyclotron radiation emission spectroscopy—Project 8
2017
The most sensitive direct method to establish the absolute neutrino mass is observation of the endpoint of the tritium beta-decay spectrum. Cyclotron Radiation Emission Spectroscopy (CRES) is a precision spectrographic technique that can probe much of the unexplored neutrino mass range with $\mathcal{O}({\rm eV})$ resolution. A lower bound of $m(\nu_e) \gtrsim 9(0.1)\, {\rm meV}$ is set by observations of neutrino oscillations, while the KATRIN Experiment - the current-generation tritium beta-decay experiment that is based on Magnetic Adiabatic Collimation with an Electrostatic (MAC-E) filter - will achieve a sensitivity of $m(\nu_e) \lesssim 0.2\,{\rm eV}$. The CRES technique aims to avoid…
A novel experimental system for the KDK measurement of the 40K decay scheme relevant for rare event searches
2020
Potassium-40 ($^{40}$K) is a long-lived, naturally occurring radioactive isotope. The decay products are prominent backgrounds for many rare event searches, including those involving NaI-based scintillators. $^{40}$K also plays a role in geochronological dating techniques. The branching ratio of the electron capture directly to the ground state of argon-40 has never been measured, which can cause difficulty in interpreting certain results or can lead to lack of precision depending on the field and analysis technique. The KDK (Potassium (K) Decay (DK)) collaboration is measuring this decay. A composite method has a silicon drift detector with an enriched, thermally deposited $^{40}$K source …
Production and characterization of a custom-made 228Th source with reduced neutron source strength for the Borexino experiment
2012
A custom-made 228Th source of several MBq activity was produced for the Borexino experiment for studying the external background of the detector. The aim was to reduce the unwanted neutron emission produced via (alpha,n) reactions in ceramics used typically for commercial 228Th sources. For this purpose a ThCl4 solution was converted chemically into ThO2 and embedded into a gold foil. The paper describes the production and the characterization of the custom-made source by means of gamma-activity, dose rate and neutron source strength measurements. From gamma-spectroscopic measurements it was deduced that the activity transfer from the initial solution to the final source was >91% (at 68%…
The magnetic shielding for the neutron decay spectrometer aSPECT
2014
Abstract Many experiments in nuclear and neutron physics are confronted with the problem that they use a superconducting magnetic spectrometer which potentially affects other experiments by their stray magnetic field. The retardation spectrometer a SPECT consists, inter alia, of a superconducting magnet system that produces a strong longitudinal magnetic field of up to 6.2 T. In order not to disturb other experiments in the vicinity of a SPECT, we had to develop a magnetic field return yoke for the magnet system. While the return yoke must reduce the stray magnetic field, the internal magnetic field and its homogeneity should not be affected. As in many cases, the magnetic shielding for a S…
Particle Identification with DIRCs at PANDA
2019
The DIRC technology (Detection of Internally Reflected Cherenkov light) offers an excellent possibility to minimize the form factor of Cherenkov detectors in hermetic high energy detectors. The PANDA experiment at FAIR in Germany will combine a barrel-shaped DIRC with a disc-shaped DIRC to cover an angular range of 5 to 140 degrees. Particle identification for pions and kaons with a separation power of 3 standard deviations or more will be provided for momenta between 0.5 GeV/c and 3.5 GeV/c in the barrel region and up to 4 GeV/c in the forward region. Even though the concept is simple, the design and construction of a DIRC is challenging. High precision optics and mechanics are required to…
Irradiation study of a fully monolithic HV-CMOS pixel sensor design in AMS 180 nm
2018
Abstract High-Voltage Monolithic Active Pixel Sensors (HV-MAPS) based on a 180 nm HV-CMOS process have been proposed to realize thin, fast and highly integrated pixel sensors. The MuPix7 prototype, fabricated in the commercial AMS H18 process, features a fully integrated on-chip readout, i.e. hit-digitization, zero suppression and data serialization. MuPix7 is the first fully monolithic HV-CMOS pixel sensor that has been tested for the use in high irradiation environments like HL-LHC. We present results from laboratory and test beam measurements of MuPix7 prototypes irradiated with neutrons (up to 5.0 × 1015 neq/cm2) and 24 GeV protons (up to 7.8 × 1015 protons/cm2) and compare the performa…