Search results for "physics.ins-det"
showing 10 items of 505 documents
Detecting the Diffuse Supernova Neutrino Background with LENA
2014
Low energy neutrino astronomy (LENA) has been proposed as a next generation 50 kt liquid scintillator detector. Its large target mass allows us to search for the diffuse supernova neutrino background (DSNB), which was generated by the cumulative emissions of all core-collapse supernovae throughout the Universe. Indistinguishable background from reactor and atmospheric electron antineutrinos limits the detection window to the energy range between 9.5 MeV and 25 MeV. Depending on the mean supernova neutrino energy, about 5 to 10 events per year are expected in this energy window. The background from neutral current reactions of atmospheric neutrinos surpasses the DSNB by more than one order m…
Novel optical interferometry of synchrotron radiation for absolute electron beam energy measurements
2018
Abstract A novel interferometric method is presented for the measurement of the absolute energy of electron beams. In the year 2016, a pioneering experiment was performed using a 195 MeV beam of the Mainz Microtron (MAMI). The experimental setup consisted of two collinear magnetic undulators as sources of coherent optical synchrotron light and a high-resolving grating monochromator. Beam energy measurements required the variation of the relative undulator distance in the decimeter range and the analysis of the intensity oscillation length in the interference spectrum. A statistical precision of 1 keV was achieved in 1 h of data taking, while systematic uncertainties of 700 keV were present …
Behavior of a trapezoid-based data acquisition system up to 100 kHz and beyond
2016
In this work, we investigated the ability of a high-purity germanium detector connected to a trapezoid-filter-based data acquisition system to reliably record signals in spite of high sample activities. By activating multiple Na$_{2}$CO$_{3}$ samples with different Na content, we were able to deduce efficiency, resolution and dead time of the system used as a function of the sample activity. Based on the results, we were able to find a setting which allows measurements of event rates up to 35~kHz per readout channel with an energy resolution of 0.3\% at the 2754 keV $^{24}$Na line.
Performance of a gamma-ray tracking array: Characterizing the AGATA array using a 60Co source
2017
International audience; The AGATA (Advanced GAmma Tracking Array) tracking detector is being designed to far surpass the performance of the previous generation, Compton-suppressed arrays. In this paper, a characterization of AGATA is provided based on data from the second GSI campaign. Emphasis is placed on the proper corrections required to extract the absolute photopeak efficiency and peak-to-total ratio. The performance after tracking is extracted and GEANT4 simulations are used both to understand the results and to scale the measurements up to predicted values for the full 4π implementation of the device.
Testbeam studies of production modules of the ATLAS Tile Calorimeter
2009
We report test beam studies of {11\,\%} of the production ATLAS Tile Calorimeter modules. The modules were equipped with production front-end electronics and all the calibration systems planned for the final detector. The studies used muon, electron and hadron beams ranging in energy from 3~GeV to 350~GeV. Two independent studies showed that the light yield of the calorimeter was $\sim 70$~pe/GeV, exceeding the design goal by {40\,\%}. Electron beams provided a calibration of the modules at the electromagnetic energy scale. Over 200~calorimeter cells the variation of the response was {2.4\,\%}. The linearity with energy was also measured. Muon beams provided an intercalibration of the respo…
Electron beam studies of light collection in a scintillating counter with embedded fibers
2021
The light collection of several fiber configurations embedded in a box-shaped plastic scintillating counter was studied by scanning with minimum ionizing electrons. The light was read out by silicon photomultipliers at both ends. The light yield produced by the 855-MeV beam of the Mainz Microtron showed a strong dependence on the transverse distance from the beam position to the fibers. The observations were modeled by attributing the collection of indirect light inside of the counter and of direct light reaching a fiber to the total light yield. The light collection with fibers was compared to that of a scintillating counter without fibers. These studies were carried out within the develop…
Particle tracking in kaon electroproduction with cathode-charge sampling in multi-wire proportional chambers
2011
Abstract Wire chambers are routinely operated as tracking detectors in magnetic spectrometers at high-intensity continuous electron beams. Especially in experiments studying reactions with small cross-sections the reaction yield is limited by the background rate in the chambers. One way to determine the track of a charged particle through a multi-wire proportional chamber (MWPC) is the measurement of the charge distribution induced on its cathodes. In practical applications of this read-out method, the algorithm to relate the measured charge distribution to the avalanche position is an important factor for the achievable position resolution and for the track reconstruction efficiency. An al…
New gas-filled mode of the large-acceptance spectrometer VAMOS
2010
A new gas-filled operation mode of the large-acceptance spectrometer VAMOS at GANIL is reported. A beam rejection factor greater than 10(10) is obtained for the Ca-40+Sm-150 system at 196 MeV. The unprecedented transmission efficiency for the evaporation residues produced in this reaction is estimated to be around 80% for alpha x n channels and above 95% for x ny p channels. A detailed study of the performance of the gas-filled VAMOS and future developments are discussed. This new operation mode opens avenues to explore the potential of fusion reactions in various kinematics. (C) 2010 Elsevier B.V. All rights reserved.
In-beam study of 253No using the SAGE spectrometer
2017
The heavy actinide nucleus 253No (Z = 102) was studied using the (S)ilicon (A)nd (Ge)rmanium (SAGE) spectrometer allowing simultaneous in-beam $\gamma$ -ray and conversion electron spectroscopy at the accelerator laboratory of the University of Jyvaskyla. Using the recoil-tagging technique, $\gamma$ -electron coincidences have allowed for the extension of the level scheme in the lower-spin region of the yrast band. In addition, internal conversion coefficient (ICC) measurements to establish the multipolarity of transitions have been performed. Measurement of the interband-intraband branching ratios supports the assignment of the Nilsson band-head configuration $9/2^{-}[734]$ assigned in pre…
A New Front-End High-Resolution Sampling Board for the New-Generation Electronics of EXOGAM2 and NEDA Detectors
2015
19th Real Time Conference (RT) -- MAY 26-30, 2014 -- Nara, JAPAN WOS: 000356458000028 This paper presents the final design and results of the FADC Mezzanine for the EXOGAM (EXOtic GAMma array spectrometer) and NEDA (Neutron Detector Array) detectors. The measurements performed include those of studying the effective number of bits, the energy resolution using HP-Ge detectors, as well as timing histograms and discrimination performance. Finally, the conclusion shows how a common digitizing device has been integrated in the experimental environment of two very different detectors which combine both low-noise acquisition and fast sampling rates. Not only the integration fulfilled the expected …