Search results for "pierre"
showing 10 items of 231 documents
The aperture for UHE tau neutrinos of the Auger fluorescence detector using a Digital Elevation Map
2005
We perform a new study of the chances of the fluorescence detector (FD) at the Pierre Auger Observatory to detect the tau leptons produced by Earth-skimming ultra high energy tau neutrinos. We present a new and more detailed evaluation of the effective aperture of the FD that considers a reliable fiducial volume for the experimental set up. In addition, we take into account the real elevation profile of the area near Auger. We find a significant increase in the number of expected events with respect to the predictions of a previous semi-analytical determination, and our results show the enhancement effect for neutrino detection from the presence of the near mountains.
Neutrino searches at the Pierre Auger Observatory
2013
Abstract The surface detector array of the Pierre Auger Observatory is sensitive to ultra-high energy neutrinos in the cosmic radiation. Neutrinos can interact in the atmosphere close to ground (down-going) and, for tau neutrinos, through the Earth-skimming mechanism (up-going) where a tau lepton is produced in the Earth crust that can emerge and decay in the atmosphere. Both types of neutrino-induced events produce an inclined particle air shower that can be identified by the presence of a broad time structure of signals in the water-Cherenkov detectors. We discuss the neutrino identification criteria used and present the corresponding limits on the diffuse and point-like source fluxes.
A facility to validate photomultipliers for the upgrade of the Pierre Auger Observatory.
2020
The Pierre Auger Observatory is undergoing a major upgrade named AugerPrime with the primary aim to add sensitivity to the mass-composition discrimination of ultrahigh-energy cosmic rays. Two different photomultipliers will be added to each water-Cherenkov station of the surface detector of Observatory. To achieve the scientific goals of AugerPrime these photomultipliers have to ensure a linear response to input-light in a wide range. This paper describes a system developed for the validation of AugerPrime-photomultipliers.
The exposure of the hybrid detector of the Pierre Auger Observatory
2010
The Pierre Auger Observatory is a detector for ultra-high energy cosmic rays. It consists of a surface array to measure secondary particles at ground level and a fluorescence detector to measure the development of air showers in the atmosphere above the array. The ‘‘hybrid” detection mode combines the information from the two subsystems. We describe the determination of the hybrid exposure for events observed by the fluorescence telescopes in coincidence with at least one water-Cherenkov detector of the surface array. A detailed knowledge of the time dependence of the detection operations is crucial for an accurate evaluation of the exposure. We discuss the relevance of monitoring data coll…
The Fluorescence Detector of the Pierre Auger Observatory
2010
The Pierre Auger Observatory is a hybrid detector for ultra-high energy cosmic rays. It combines a surface array to measure secondary particles at ground level together with a fluorescence detector to measure the development of air showers in the atmosphere above the array. The fluorescence detector comprises 24 large telescopes specialized for measuring the nitrogen fluorescence caused by charged particles of cosmic ray air showers. In this paper we describe the components of the fluorescence detector including its optical system, the design of the camera, the electronics, and the systems for relative and absolute calibration. We also discuss the operation and the monitoring of the detecto…
Observation of inclined EeV air showers with the radio detector of the Pierre Auger Observatory
2018
With the Auger Engineering Radio Array (AERA) of the Pierre Auger Observatory, we have observed the radio emission from 561 extensive air showers with zenith angles between 60 and 84. In contrast to air showers with more vertical incidence, these inclined air showers illuminate large ground areas of several km2 with radio signals detectable in the 30 to 80 MHz band. A comparison of the measured radio-signal amplitudes with Monte Carlo simulations of a subset of 50 events for which we reconstruct the energy using the Auger surface detector shows agreement within the uncertainties of the current analysis. As expected for forward-beamed radio emission undergoing no significant absorption or sc…
Reconstruction of events recorded with the surface detector of the Pierre Auger Observatory
2020
Cosmic rays arriving at Earth collide with the upper parts of the atmosphere, thereby inducing extensive air showers. When secondary particles from the cascade arrive at the ground, they are measured by surface detector arrays. We describe the methods applied to the measurements of the surface detector of the Pierre Auger Observatory to reconstruct events with zenith angles less than 60 using the timing and signal information recorded using the water-Cherenkov detector stations. In addition, we assess the accuracy of these methods in reconstructing the arrival directions of the primary cosmic ray particles and the sizes of the induced showers.
Search for point-like sources of ultra-high energy neutrinos at the pierre auger observatory and improved limit on the diffuse flux of tau neutrinos
2012
The surface detector array of the Pierre Auger Observatory can detect neutrinos with energy Eν between 1017 eV and 1020 eV from point-like sources across the sky south of +55º and north of −65º declinations. A search has been performed for highly inclined extensive air showers produced by the interaction of neutrinos of all flavors in the atmosphere (downward-going neutrinos), and by the decay of tau leptons originating from tau neutrino interactions in Earth’s crust (Earth-skimming neutrinos). No candidate neutrinos have been found in data up to 2010 May 31. This corresponds to an equivalent exposure of ∼3.5 years of a full surface detector array for the Earth-skimming channel and ∼2 years…
Search for ultrahigh energy neutrinos in highly inclined events at the Pierre Auger Observatory
2011
Erratum: Phys. Rev. D 85, 029902(E) (2012) [http://dx.doi.org/10.1103/PhysRevD.85.029902]
Removal of streaking artefact in the images of the Pierre Auger Observatory infra-red cameras
2011
In this paper the problem of removing concentric semi-circular stripe artefacts induced by the operating hardware of the infra red cameras of the Pierre Auger Observatory, is tackled. The method builds on top of a recent algorithm for the removal of artefacts, which presents a robust filter, obtained as a combination of Wavelet and Fourier analysis, capable of eliminating horizontal and vertical stripes in images, while trying to preserve structural features and quantitative values of the image. The method requires several parameters which have been tuned by an exhaustive test on a large set of images. The results show that the method is capable to satisfactorily remove the stripe artefacts.