BEM analysis of a piezoelectric structural health monitoring system for delamination detection

2013

In the present work a piezoelectric based structural health monitoring (SHM) system is analyzed with the aim of assessing the ability of the piezoelectric patch to detect both edge and embedded delaminations proper of flange-skin composite laminated structures. he boundary element model is developed for piezoelectric solids and is implemented by taking advantage of the multidomain technique to model laminated and cracked configurations. A non-linear spring model interface is then implemented in conjunction with an iterative procedure allowing for the simulation of the finite stiffness of the bonding layers as well as of the non-penetration condition of the delamination surfaces. he dynamic …

piezoelectricsMaterials scienceFracture mechanicPiezoelectric mediaStructural health monitoring DelaminationPiezoelectric devicePiezoelectricityPiezoelectric materialNon-penetration conditionFlangeStructural Healt MonitoringStructural health monitoring systems Boundary element methodmedicineFracture mechanics behaviorGeneral Materials ScienceLaminatingSettore ING-IND/04 - Costruzioni E Strutture AerospazialiBoundary element methodStrain energy release ratebusiness.industryMechanical EngineeringDelaminationComposite laminated structureStiffnessFracture mechanicsStructural engineeringBoundary element modelDamage detectionPiezoelectricityIterative methodFractureMechanics of MaterialsReciprocity (electromagnetism)DelaminationIdentification parameterStructural health monitoringmedicine.symptomStructural health monitoring (SHM)business
researchProduct

On the use of the EMI for the health monitoring of bonded elements

2014

The low weight, robustness and fatigue resistance of adhesive joints make them suitable for structural joints. A fully developed nondestructive evaluation technique however is needed to monitor and assess the quality of bonded joints. In the present paper the application of the electromechanical impedance (EMI) technique is proposed. In the EMI method a piezoelectric transducer (PZT) is attached to the structure of interest. The high sensitivity and low power consumption make the EMI method feasible for real time structural health monitoring. In this study we investigated the sensitivity of the electromechanical response of a PZT to the curing and the quality of the adhesive used for bonded…

piezoelectricsMaterials sciencebusiness.industryElectromagnetic Impedance EMI Structural Health MOnitoringPiezoelectricityTransducerEMINondestructive testingWave impedanceStructural health monitoringComposite materialSettore ING-IND/04 - Costruzioni E Strutture AerospazialibusinessElectrical conductorElectrical impedanceSensorSPIE Proceedings