Search results for "placement"
showing 10 items of 1142 documents
Cardiovascular Disease and SERMs
2006
Accuracy of stereotactic coordinate transformation using a localisation frame and computed tomographic imaging
1999
The accuracy of coordinate transformation from a CT image to a stereotactic frame was investigated for stereotactic systems using a localisation frame and matrix-based coordinate transformation. The main source of error influencing calculation was input data, due to inaccurate calculation of the centres of the rods of the localisation frame in the CT image, and the propagation of this input error during subsequent matrix calculation. Systemic errors during matrix calculation do not exist, and rounding off errors were of subordinate importance compared to the input data error. The influence of input data error on coordinate transformation was studied by geometric methods, computer simulation…
Effect of the lack of primary stability in the survival of dental implants
2018
Background The survival of dental implants has been linked to primary stability. The aim of this study is to analyse the factors that influence the survival of dental implants placed without primary stability. Material and methods A cohort study of implants placed without primary stability was carried out between September 2011 and July 2016. All cases with registered information on the patient and surgical intervention were used. Cases that did not have a 12-month follow-up after implant placement were excluded. Results Out of 2,400 analysed implants, 92 were placed without primary stability. The absence of primary stability was classified as B in 49 cases, C in 38 cases and D in 5 cases. …
Sensorless control of permanent magnet synchronous motors for wide speed range applications
2006
This paper deals with sensorless control of Interior Permanent Magnet Synchronous Motors (IPMS) based on the estimation of speed and rotor angular position. The above estimate is based on the injection of high frequency stator currents able to generate a signal similar to that generated by a resolver connected to the axis of the motor. A new digital algorithm has been designed to demodulate the above signal whose implementation can be carried out on the same DSP that processes the control algorithm. In this paper a new scheme of speed and angular position estimator is proposed and justified on the theoretic point of view. The experimental results here shown validate the effectiveness of the…
Digital Hydraulic Winch Drives
2018
This paper presents the planned use of digital displacement high torque low speed motors to drive large winches in off-shore and maritime applications. The digital displacement technology uses forced actuation of high- and low pressure valves for each cylinder chamber, i.e. valves are opened and closed by actuation forces independently of cylinder pressure and supply pressures. Motors equipped with the technology are well suited for low speed secondary controlled operation including start and stop. It also enables unloading of motor cylinders that are not needed to produce torque, whereby excellent efficiency at partial displacement is obtained. A research project on application of multi di…
Survival of implants placed with the osteotome technique : an update. Review
2012
A literature review is made to analyze the survival of implants placed with the osteotome technique. A PubMed search was made based on the key words “osteotome AND dental implants”, corresponding to publications between 1998-2008. The inclusion criteria were: a) a minimum of 10 patients; b) a minimum follow-up of 6 months; c) implants placed using the osteotome technique with or without indirect sinus lift; and d) specification of the implant number and survival rate. Sixty-four articles were identified, of which 20 met the inclusion criteria. A total of 2006 implants were placed in 1312 patients using the osteotome technique. The duration of follow-up after prosthetic loading ranged from 6…
Optimization of CASA-Mot Analysis of Donkey Sperm : optimum Frame Rate and Values of Kinematic Variables for Different Counting Chamber and Fields
2020
In order to optimize the donkey sperm motility analysis by the CASA (Computer Assisted Sperm Analysis)-Mot system, twelve ejaculates were collected from six jackasses. Capillary loaded chamber (CLC), ISAS®
FACTORS INFLUENCING CAREER CHOICE AMONG NURSING STUDENTS
2018
Choosing a career is a complex and multi-factorial decision-making process that is based on several personal, situational and organizational factors. The purpose of this study is a literature review to determine factors influencing career choice among nursing students. The literature review displays that nursing students make their career decisions from a combination of personal interests in health care and their desire to help others. From the beginning of the studies students may have strong career preferences. Before they graduate and eventually decide about the future workplace, their career choices undergo several transitions. Career choices are influenced both by the students inclina…
Financial Aspects of Cervical Disc Arthroplasty: A Narrative Review of Recent Literature
2020
Recently, there has been significant interest in understanding the cost-effectiveness of treatments in spine surgery as health care systems in the United States move toward value-based care and alternative payment models. Previous studies have shown comparable outcomes of cervical disc arthroplasty (CDA) and anterior cervical discectomy fusion; however, there is a lack of consensus on the cost-effectiveness of CDA to support full adoption. Evidence of the limitations of these cost-analysis studies also exists in the literature, including industry funding, potential selection bias, and varying methods of calculating value. The goal of this narrative review is to provide an overview of the co…
Safety and efficacy of cervical disc arthroplasty in preventing the adjacent segment disease: a meta-analysis of mid- to long-term outcomes in prospe…
2019
Objectives: Cervical disc arthroplasty (CDA) has become an alternative treatment for cervical radiculopathy and myelopathy. This technique preserves appropriate motion at both the index and adjacent disc levels and consequently may prevent adjacent segment degeneration (ASD). The authors performed a meta-analysis to compare the safety and efficacy of CDA to those of the gold standard, anterior cervical discectomy and fusion (ACDF). Both surgical and clinical parameters were employed to verify the hypothesis that CDA can reduce the risk of ASD. Methods: The meta-analysis comprised high-quality randomized controlled trials that compared CDA and ACDF treatments of cervical degenerative disc di…