Search results for "plates"
showing 10 items of 123 documents
Innovative straight formulation for plate in bending
2017
In this paper it has been introduced an innovative formulation for evaluating the deflection function of a simply supported plate loaded by uniformly distributed edge moments. Framed into Line Element-less Method, this formulation allows the evaluation of solution in terms of deflection, through few lines of algorithm implemented by Mathematica software without resorting to any discretization neither in the domain nor in the boundary. Interesting savings in terms of time and computational costs are achieved. Results obtained by the proposed method are well contrasted by ones obtained by classical methods and Finite Element Method.
Large deflection analysis of magneto-electro-elastic laminates
2013
Magneto-electro-elastic (MEE) composites containing piezoelectric and piezo-magnetic phases have recently emerged for many application smart structures technology. In this framework, the development of tools to analyze the MEE laminates is essential for their efficient design. In the present work, a model for the large deflection analysis of MEE laminated plates is proposed. The first order shear deformation theory and the von Karman stress function approach are employed to model the mechanical behavior whereas quasi-static behavior is assumed for the electro-magnetic quantities. First, the magneto-electric problem is solved in terms of the plate mechanical primary variables. In turn, this …
Volar Fixed-Angle Plating of Distal Radius Fractures
2011
The purpose of this biomechanical study was to determine whether a multidirectional fixed-angle plate with locking screws or with locking pegs in the distal fragment would optimize fixation of Orthopaedic Trauma Association (OTA) type A3 distal radius fractures.Eight pairs of fresh-frozen human distal radii were used. Extra-articular distal radius fractures were created and stabilized with a multidirectional volar fixed-angle plate. The radii were randomized into 2 matched-paired groups. The distal fragment in Group I was stabilized with 7 locking screws. The distal fragment in Group II was fixed with 7 locking pegs. The proximal fragment in both groups was fixed with 3 screws. The specimen…
Intraosseous Fixation Compared to Plantar Plate Fixation for First Metatarsocuneiform Arthrodesis
2014
Background: Metatarsocuneiform (MTC) fusion is a treatment option for management of hallux valgus. We compared the biomechanical characteristics of an internal fixation device with plantar plate fixation. Methods: Seven matched pairs of feet from human cadavers were used to compare the intramedullary (IM) device plus compression screw to plantar plate combined with a compression screw. Specimen constructs were loaded in a cyclic 4-point bending test. We obtained initial/final stiffness, maximum load, and number of cycles to failure. Bone mineral density was measured with peripheral quantitative computed tomography. Performance was compared using time to event analysis with number of cycles …
New iPAD-based test for the detection of color vision deficiencies.
2018
Purpose: To develop and validate a new iPad-based color vision test (Optopad). Methods: A total of 341 student eyes were enrolled in a first comparative study between Optopad and the Isihara tests. In a second comparative study, Optopad vs. the Farnworth-Munsell test (FM 100H), a total of 66 adult eyes were included. Besides the agreement between tests, the correlation between FM 100H and Optopad outcomes were investigated. Multiple regression analysis was used to predict the total error score (TES) from contrast thresholds measured with the Optopad test. Results: The Ishihara and Optopad tests detected the same anomalous patients. Concerning FM 100H vs. Optopad, 10 subjects were diagnosed …
Local and systemic risk factors influencing the long-term success of angular stable alloplastic reconstruction plates of the mandible
2013
Introduction: After ablative surgery of the mandible, angular stable alloplastic reconstruction plates are commonly employed. The aim of the study was a long-term evaluation of local anatomical, as looking at systemic factors influencing specific complications and the failure rate of such plates. Materials and methods: In a retrospective study covering an 11-year period, we reviewed the outcomes of angular stable plates of patients who had a segmental resection of the mandible and subsequent alloplastic reconstruction. Complications and failure rates were assessed and local (anatomical size and localization of resection) as well as systemic risk factors (age, sex, radiation therapy, smoking…
Locking plates for corrective osteotomy of malunited dorsally tilted distal radial fractures: a biomechanical study.
2005
The purpose of the study was to compare the biomechanical properties of five different palmar fixation plate designs in a distal radius osteotomy cadaver model. A 1 cm metaphyseal osteotomy gap was made to simulate a corrective osteotomy and the osteotomy plated. Axial load was applied to the distal end of each construct by a material testing machine under control of a motion analysis video system. The specimens were arranged into five implant groups of eight specimens each. No test group developed deformity and movement of the fracture gap greater than 2 mm with a load of 100 N. Increasing the load to 250 N revealed statistically significant differences in stiffness and failure load betwe…
Number and Locations of Screw Fixation for Volar Fixed-Angle Plating of Distal Radius Fractures: Biomechanical Study
2010
Purpose To compare the biomechanical properties of different numbers and locations of screws in a multidirectional volar fixed-angle plate in a distal radius osteotomy cadaver model. Methods We created an extra-articular fracture in 16 pairs of fresh-frozen human cadaver radiuses. The 32 specimens were randomized into 4 groups. All fractures were fixated with a multidirectional volar fixed-angle plate. We tested 4 different screw-placement options in the distal fragment. The distal fragment was fixed with 4 locking screws in the distal row of the plate in group a, and with 4 locking screws alternately in the distal and proximal rows in group b. In group c, 3 locking screws were used in the …
Analytical Refinement of Sandwich Plate Bending Problem Considering Local Effects-I
1999
Analytic expressions for local flexural characteristics and stresses of sandwich panels under loading by point forces have been found. A discrete-layer model for bending of a three-layer panel with a soft filler is proposed. Contractility of a normal in the model is deduced in terms of a difference between deflections of face layers. The accountability of transverse shear in the filler and the sheets is deduced on piecewise rotation of the normal. Equations of the model having four degrees of displacement freedom are of twelfth order. The specific features of the stress from point forces in cylindrical bending are considered using the operational Laplace method with the generalized Dirac f…
Large deflection of magneto-electro-elastic laminated plates
2014
Abstract A model for the large deflection analysis of magneto-electro-elastic laminated plates is derived. The first order shear deformation theory and the von Karman stress function approach are employed. A set of resolving partial differential equations involving kinematical variables and the stress function is obtained as a consequence of the preliminary condensation of the electro-magnetic state to the plate kinematics. A closed form solution for simply-supported plates is presented. Numerical results are carried out for plates consisting of piezoelectric BaTiO 3 and piezomagnetic CoFe 2 O 4 layers. These results show the influence of large deflections on the plate response and could be…