Search results for "projection"

showing 10 items of 378 documents

Time-resolved classification of dog brain signals reveals early processing of faces, species and emotion

2020

Dogs process faces and emotional expressions much like humans, but the time windows important for face processing in dogs are largely unknown. By combining our non-invasive electroencephalography (EEG) protocol on dogs with machine-learning algorithms, we show category-specific dog brain responses to pictures of human and dog facial expressions, objects, and phase-scrambled faces. We trained a support vector machine classifier with spatiotemporal EEG data to discriminate between responses to pairs of images. The classification accuracy was highest for humans or dogs vs. scrambled images, with most informative time intervals of 100–140 ms and 240–280 ms. We also detected a response sensitive…

MaleEmotionslcsh:MedicinehavaitseminenperceptionFAMILIAR413 Veterinary scienceBehavioural methodsMachine Learningsocial behaviourEXPRESSIONSAnimal physiologyEVOKED-POTENTIALSEEGNeural decodingvertaileva psykologialcsh:Sciencesocial evolutionVisual CortexSocial evolutionelectroencephalography – EEGElectroencephalographyAnimal behaviourPublisher Correctionneural decodinganimal physiologySocial behaviourFemalesosiaalinen käyttäytyminenihminen-eläinsuhdeFacial RecognitionERPElectroencephalography - EEGanimal behaviourevoluutioemotionEVENT-RELATED POTENTIALSkoiraeläinten käyttäytyminenArticleDogsSpatio-Temporal AnalysistunteetAnimalsEmotionlcsh:RATTENTIONDISCRIMINATIONPROJECTIONSPerceptionlcsh:QPhotic Stimulationbehavioural methodsRESPONSESScientific Reports
researchProduct

Coronary CT angiography using iterative reconstruction 
vs. filtered back projection: evaluation of image quality.

2014

To compare image quality of iterative reconstruction algorithm(IRIS) vs. standard filtered back projection(FBP) reconstruction in CT Coronary Angiography (CTCA).Thirty-four consecutive patients underwent CTCA for suspected or known CAD with Dual-Source CT (DSCT-Flash, Siemens). All datasets were reconstructed with 0.75/0.4 and 0.6/0.4 mm slice thickness/increment, using three standard FBP kernels (B26-B30-B46) and three comparable IRIS algorithms (I26-I30-I46). Vascular attenuation and noise were measured. CT vascular attenuation values [HU] were measured in: ascending aorta (Ao), right (RCA) and left (LCA) coronary artery, respectively. Signal-to-noise (SNR) and contrast-to-noise (CNR) rat…

MaleImage Processing Computer-AssistedHumansFemaleCoronary Artery DiseaseProspective StudiesMiddle Agediterative reconstruction signal noise cardiac CT filtered back projectionSettore MED/36 - Diagnostica Per Immagini E RadioterapiaCoronary AngiographyTomography X-Ray ComputedAlgorithmsAged
researchProduct

Children Like Dense Neighborhoods: Orthographic Neighborhood Density Effects in Novel Readers

2008

Previous evidence with English beginning readers suggests that some orthographic effects, such as the orthographic neighborhood density effects, could be stronger for children than for adults. Particularly, children respond more accurately to words with many orthographic neighbors than to words with few neighbors. The magnitude of the effects for children is much higher than for adults, and some researchers have proposed that these effects could be progressively modulated according to reading expertise. The present paper explores in depth how children from 1stto 6thgrade perform a lexical decision with words that are from dense or sparse orthographic neighborhoods, attending not only to acc…

MaleLinguistics and Languagemedia_common.quotation_subjectVocabularyDensity effectLanguage and LinguisticsTask (project management)Developmental psychologyDiscrimination LearningJudgmentUNESCO::PSICOLOGÍA::Psicología del niño y del adolescente::Problemas de aprendizajeLexical access; Reading development; Orthographic neighborhood; Density effectReading (process)Reaction TimeLexical decision taskHumansOrthographic neighborhoodChildGeneral Psychologymedia_commonVisual word recognitionPsycholinguistics:PSICOLOGÍA::Psicología del niño y del adolescente::Problemas de aprendizaje [UNESCO]Orthographic projectionCognitionVerbal LearningPreferenceSemanticsLanguage developmentPattern Recognition VisualReadingReading developmentLexical accessFemalePsychologyPsychomotor PerformanceThe Spanish Journal of Psychology
researchProduct

Temporal stability and representational distinctiveness: Key functions of orthographic working memory

2011

A primary goal of working memory research has been to understand the mechanisms that permit working memory systems to effectively maintain the identity and order of the elements held in memory for sufficient time as to allow for their selection and transfer to subsequent processing stages. Based on the performance of two individuals with acquired dysgraphia affecting orthographic working memory (WM; the graphemic buffer), we present evidence of two distinct and dissociable functions of orthographic WM. One function is responsible for maintaining the temporal stability of letters held in orthographic WM, while the other is responsible for maintaining their representational distinctiveness. T…

MaleTime FactorsCognitive NeuroscienceExperimental and Cognitive PsychologySemanticsworking memoryArticledysgraphiaworking memory; spelling; dysgraphia; orthographic representationsspellingArts and Humanities (miscellaneous)DysgraphiaDevelopmental and Educational PsychologymedicineSelection (linguistics)HumansAgraphiaAgedSettore M-PSI/02 - Psicobiologia E Psicologia FisiologicaWorking memoryorthographic representationsOrthographic projectionMiddle Agedmedicine.diseaseSemanticsSerial position effectMemory Short-TermNeuropsychology and Physiological PsychologyAgraphiaOptimal distinctiveness theorymedicine.symptomPsychologyPsychomotor PerformanceCognitive psychologyCognitive Neuropsychology
researchProduct

Imaging processing for CT angiography of the cervicocranial arteries: evaluation of reformatting technique.

2007

Purpose. The aim of this study was to compare computed tomography angiography (CTA) sliding-thin-slab (STS) multiplanar reformatting (MPR), STS maximum intensity projection (MIP) and three-dimensional (3D) volume rendering (VR) reformatting techniques in the evaluation of cervicocranial arteries. Materials and methods. Twenty patients examined with multislice CT were included in this study. CTA images were reformatted as STS-MIP, STS-MPR and 3DVR in orthogonal planes and in the oblique-coronal plane. Images were evaluated in consensus by two radiologists, with a third radiologist to resolve discordances in grading image quality parameters. The Spearman correlation analysis was performed to …

Malemedicine.medical_specialtyImage qualityCT CT angiography Cervicocranial arterieImaging Three-DimensionalmedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingVertebral ArteryComputed tomography angiographyNeuroradiologyAgedmedicine.diagnostic_testbusiness.industryUltrasoundAngiographyBrainVolume renderingGeneral MedicineCerebral ArteriesMiddle AgedCerebral AngiographyCerebrovascular DisordersCarotid ArteriesMaximum intensity projectionAngiographyCervical VertebraeFemaleRadiologyImaging processingNuclear medicinebusinessTomography X-Ray ComputedLa Radiologia medica
researchProduct

Value of magnetic-resonance cholangio-pancreatography (MRCP) after unsuccessful endoscopic-retrograde cholangio-pancreatography (ERCP).

1997

Background and Study Aims: The present study tries to evaluate the success rate of MRCP when two attempts by experts to perform ERCP in a center failed. Patients and Methods: From March 1996 to December 1996 thirteen patients fulfilled the inclusion criteria. The MR cholangiopancreatograms were acquired using commercially available software in a clinical MR scanner (Magnetom Expert 1T-Scanner, Siemens, Erlangen, Germany). MRCP utilized heavily T2-weighted turbo-spin echo sequences with fat supression (HASTE). Maximum intensity projection (MIP) of the pancreatic duct and biliary tree was then carried out. Additionally, T1-weighted sequences were obtained using the breath-hold technique. Resu…

Malemedicine.medical_specialtyPercutaneousPancreatic pseudocystBiliary Tract DiseasesmedicineImage Processing Computer-AssistedHumansMedical diagnosisAgedPancreatic ductAged 80 and overCholangiopancreatography Endoscopic Retrogrademedicine.diagnostic_testbusiness.industryBile ductGastroenterologyPancreatic DiseasesMagnetic resonance imagingMiddle Agedmedicine.diseaseMagnetic Resonance Imagingmedicine.anatomical_structureMaximum intensity projectionFemaleRadiologybusinessEndoscopic retrograde cholangio-pancreatographyEndoscopy
researchProduct

Diagnostic performance of whole brain volume perfusion CT in intra-axial brain tumors: preoperative classification accuracy and histopathologic corre…

2012

Abstract Background To evaluate the preoperative diagnostic power and classification accuracy of perfusion parameters derived from whole brain volume perfusion CT (VPCT) in patients with cerebral tumors. Methods Sixty-three patients (31 male, 32 female; mean age 55.6 ± 13.9 years), with MRI findings suspected of cerebral lesions, underwent VPCT. Two readers independently evaluated VPCT data. Volumes of interest (VOIs) were marked circumscript around the tumor according to maximum intensity projection volumes, and then mapped automatically onto the cerebral blood volume (CBV), flow (CBF) and permeability Ktrans perfusion datasets. A second VOI was placed in the contra lateral cortex, as cont…

Malemedicine.medical_specialtyPerfusion ImagingHemodynamicsSensitivity and Specificity030218 nuclear medicine & medical imagingCorrelation03 medical and health sciences0302 clinical medicineImaging Three-DimensionalCortex (anatomy)Preoperative CaremedicineHumansRadiology Nuclear Medicine and imagingNeovascularization Pathologicbusiness.industryBrain NeoplasmsReproducibility of ResultsGeneral MedicineMiddle AgedPrognosisTumor BurdenCerebral blood volumemedicine.anatomical_structureMaximum intensity projectionBrain sizeCerebral hemisphereRadiographic Image Interpretation Computer-AssistedFemaleRadiologyNuclear medicinebusinessTomography X-Ray ComputedPerfusion030217 neurology & neurosurgeryAlgorithmsEuropean journal of radiology
researchProduct

Evaluation of post-myocardial infarction regional and global left ventricular function by monoplane ventriculography: superiority of right versus lef…

1996

OBJECTIVES To study the significance of serial quantitative regional wall motion analysis, volumes, and ejection fraction findings as well as their prognostic implications derived from cineventriculography in 30 degrees right anterior oblique (RAO) projection in comparison with 60 degrees left anterior oblique (LAO) projection in post-myocardial infarction patients. Ventriculographic left ventricular parameters are accepted surrogates of mortality in myocardial infarction. Nowadays, in contrast to a biplanar approach in most institutions and clinical trials, the investigation is reduced to monoplanar ventriculography. However, it is not known whether the relevance of the two established pro…

Malemedicine.medical_specialtyStreptokinaseMyocardial InfarctionInfarctionPost myocardial infarctionVentricular Function LeftInternal medicineMedicineHumansMyocardial infarctionAngioplasty Balloon CoronaryVentricular remodelingProjection (set theory)Ejection fractionbusiness.industryGated Blood-Pool ImagingStroke VolumeGeneral MedicineMiddle Agedmedicine.diseaseThrombosisSurvival AnalysisEvaluation Studies as TopicCardiologyFemaleCardiology and Cardiovascular Medicinebusinessmedicine.drugCoronary artery disease
researchProduct

Three dimensional reconstruction to visualize atrial fibrillation activation patterns on curved atrial geometry

2021

BackgroundThe rotational activation created by spiral waves may be a mechanism for atrial fibrillation (AF), yet it is unclear how activation patterns obtained from endocardial baskets are influenced by the 3D geometric curvature of the atrium or ‘unfolding’ into 2D maps. We develop algorithms that can visualize spiral waves and their tip locations on curved atrial geometries. We use these algorithms to quantify differences in AF maps and spiral tip locations between 3D basket reconstructions, projection onto 3D anatomical shells and unfolded 2D surfaces.MethodsWe tested our algorithms in N = 20 patients in whom AF was recorded from 64-pole baskets (Abbott, CA). Phase maps were generated by…

Malemedicine.medical_treatmentGeometryProjection (mathematics)Atrial FibrillationMedicine and Health SciencesElectrochemistryPower DistributionAtrium (heart)Cardiac AtriaSpiralPhysicsNumerical AnalysisMultidisciplinaryApplied MathematicsSimulation and ModelingQRAtrial fibrillationSignal Processing Computer-AssistedHeartMiddle AgedAblationChemistrymedicine.anatomical_structurePhysical SciencesCatheter AblationMedicineEngineering and TechnologyGravitational singularityFemaleAnatomyElectrophysiologic Techniques CardiacAlgorithmsArrhythmiaResearch ArticleBiotechnologyPower GridsCathetersSciencePhase (waves)CardiologyGeometryBioengineeringCurvatureResearch and Analysis MethodsImaging Three-DimensionalmedicineHumansImatges tridimensionals en medicinaCurvatureElectrode PotentialsBiology and Life Sciencesmedicine.diseaseInterpolationEnergy and PowerCardiovascular AnatomyMedical Devices and EquipmentMathematics
researchProduct

Costs and Benefits of Orthographic Inconsistency in Reading: Evidence from a Cross-Linguistic Comparison.

2016

We compared reading acquisition in English and Italian children up to late primary school analyzing RTs and errors as a function of various psycholinguistic variables and changes due to experience. Our results show that reading becomes progressively more reliant on larger processing units with age, but that this is modulated by consistency of the language. In English, an inconsistent orthography, reliance on larger units occurs earlier on and it is demonstrated by faster RTs, a stronger effect of lexical variables and lack of length effect (by fifth grade). However, not all English children are able to master this mode of processing yielding larger inter-individual variability. In Italian, …

Maleorthographic consistencyCost-Benefit AnalysisSocial Scienceslcsh:MedicineAcademic SkillsPsycholinguisticsLiteracyFamilies0302 clinical medicineSociologyReading (process)PsychologyEthnicitiesChildlcsh:ScienceChildrenreading; cross-linguistic; orthographymedia_commonLanguageorthographyMultidisciplinaryPsycholinguisticsSchoolsCost–benefit analysis05 social sciencesOrthographic projectionSyllablescross-linguisticItalian PeopleLanguage developmentEnglandItalyFemalePsychologyCognitive psychologyCross linguisticResearch Articlemedia_common.quotation_subjectPhonologyLanguage Development050105 experimental psychologyEducation03 medical and health sciencesLiteracyReading acquisitionHumans0501 psychology and cognitive scienceslcsh:RCognitive PsychologyBiology and Life SciencesPhonemesReproducibility of ResultsLinguisticsReadingAge Groupscross-linguistic comparisonPeople and PlacesCognitive SciencePopulation Groupingslcsh:Q030217 neurology & neurosurgeryOrthographyNeurosciencePLoS ONE
researchProduct