Search results for "pulse"
showing 10 items of 1508 documents
Comparison of transient elastography and acoustic radiation force impulse for non-invasive staging of liver fibrosis in patients with chronic hepatit…
2011
Transient elastography (TE) is adequate for a diagnosis of cirrhosis, but its accuracy for milder stages of fibrosis is much less satisfactory. The objective of this study was to compare the performance and the discordance rate of acoustic radiation force impulse (ARFI) and TE with liver biopsy in a cohort of chronic hepatitis C (CHC) patients.One hundred thirty-nine consecutive patients with CHC were enrolled in two tertiary centers, and evaluated for histological (Metavir score) and biochemical features. All patients underwent TE and ARFI.TE was unreliable in nine patients (6.5%), while in no cases (0%) were ARFI invalid measurements recorded (P=0.029). By area under receiver operating ch…
Contingent biofeedback outperforms other methods to enhance the accuracy of cardiac interoception: A comparison of short interventions.
2019
Abstract Background and objectives Deviations in interoception might contribute to the development and maintenance of mental disorders. The improvement of interoceptive accuracy (IA) is desirable but assessment and training methods remain controversial. For instance, it was assumed that performance increases in heartbeat counting paradigms after cardiac feedback were due to an improvement of knowledge with regard to heart rate rather than due to an actual improvement in IA. Methods Here, we examined effects of contingent cardiac feedback training, non-contingent cardiac feedback, mindfulness practice, and a waiting period with external attentional focus on IA. 100 healthy participants under…
Occurrence and clinical characteristics of Compulsive Sexual Behavior Disorder (CSBD): A cluster analysis in two independent community samples.
2020
AbstractBackground and aimsCompulsive Sexual Behavior Disorder (CSBD) is characterized by a persistent failure to control intense and recurrent sexual impulses, urges, and/or thoughts, resulting in repetitive sexual behavior that causes a marked impairment in important areas of functioning. Despite its recent inclusion in the forthcoming ICD-11, concerns regarding its assessment, diagnosis, prevalence or clinical characteristics remain. The purpose of this study was to identify participants displaying CSBD through a novel data-driven approach in two independent samples and outline their sociodemographic, sexual, and clinical profile.MethodsSample 1 included 1,581 university students (female…
Synchronization to metrical levels in music depends on low-frequency spectral components and tempo
2016
Previous studies have found relationships between music-induced movement and musical characteristics on more general levels, such as tempo or pulse clarity. This study focused on synchronization abilities to music of finely-varying tempi and varying degrees of low frequency spectral change/flux. Excerpts from six classic Motown/R&B songs at three different tempos (105, 115, and 130 BPM) were used as stimuli in this experiment. Each was then time-stretched by a factor of 5% with regards to the original tempo, yielding a total of 12 stimuli that were presented to 30 participants. Participants were asked to move along with the stimuli while being recorded with an optical motion capture system.…
Prismatic Adaptation as a Novel Tool to Directionally Modulate Motor Cortex Excitability: Evidence From Paired-pulse TMS
2014
Abstract Background The prismatic adaptation (PA) is a visuo-motor procedure that has captured the attention of neuroscientists in the last decades, hence it seems to affect high-order cognition. However, the basic neural processes related to PA and its effects on cortical plasticity are not clear yet. Objective/hypothesis The aim of the present study is to explore whether PA induces a direct effect on the motor cortices (M1) excitability. Methods Fourteen healthy participants were submitted to paired-pulse TMS to measure short-intracortical-inhibition (SICI) and intracortical-facilitation (ICF) on both the left and the right M1, before and after PA, that could induce a leftward or rightwar…
Biomechanical analysis of different starting strategies utilized during cross-country skiing starts
2016
The present study was designed to analyse and compare the kinetics and kinematics associated with three different starting strategies during classic cross-country ski racing. Inside a ski tunnel, 12 elite male skiers performed three sets of three 38 m starts. Each set included one start using: double poling only (DP), diagonal stride only (DIA) and freely chosen (FREE) (i.e. where subjects used the strategy or combination of strategies they felt was fastest) in random order. The first 18 m was performed on a series of force plates that measured horizontal and vertical forces followed by 20 m of a standard snow track. Additionally, cycle characteristics and joint angles were measured. DIA an…
Radiofrequency treatment of cervicogenic headache
2010
Objectives: In the clinical management of facial pain, a possible cervical origin must be considered. A clinical exploration is therefore essential. The disorder originates in the intimate connections between the cranial portion of the spinal cord and the trigeminal system. Although solid evidence supporting the use of radiofrequency (RF) treatment is lacking, it remains one of the management options to be taken into account. The present study evalu - ates the efficacy of RF in application to cervicogenic headache. Study design: We present three cases of severe facial pain arising from different cervical structures. Results: In two cases the pain originated in cervical roots C2 and C3, whil…
Human sleep under the influence of pulsed radiofrequency electromagnetic fields: A polysomnographic study using standardized conditions
1998
To investigate the influence of radiofrequency electromagnetic fields (EMFs) of cellular phone GSM signals on human sleep electroencephalographic (EEG) pattern, all-night polysomnographies of 24 healthy male subjects were recorded, both with and without exposure to a circular polarized EMF (900 MHz, pulsed with a frequency of 217 Hz, pulse width 577 μs, power flux density 0.2 W/m2. Suppression of rapid eye movement (REM) sleep as well as a sleep-inducing effect under field exposure did not reach statistical significance, so that previous results indicating alterations of these sleep parameters could not be replicated. Spectral power analysis also did not reveal any alterations of the EEG rh…
Automatic algorithm for monitoring systolic pressure variation and difference in pulse pressure.
2009
BACKGROUND: Difference in pulse pressure (dPP) reliably predicts fluid responsiveness in patients. We have developed a respiratory variation (RV) monitoring device (RV monitor), which continuously records both airway pressure and arterial blood pressure (ABP). We compared the RV monitor measurements with manual dPP measurements. METHODS: ABP and airway pressure (PAW) from 24 patients were recorded. Data were fed to the RV monitor to calculate dPP and systolic pressure variation in two different ways: (a) considering both ABP and PAW (RV algorithm) and (b) ABP only (RV(slim) algorithm). Additionally, ABP and PAW were recorded intraoperatively in 10-min intervals for later calculation of dPP …
Comparison of three accelerated pulse sequences for semiquantitative myocardial perfusion imaging using sensitivity encoding incorporating temporal f…
2007
Purpose To investigate the parallel acquisition technique sensitivity encoding incorporating temporal filtering (TSENSE) with three saturation-recovery (SR) prepared pulse sequences (SR turbo fast low-angle shot [SR-TurboFLASH], SR true fast imaging with steady precession [SR-TrueFISP], and SR-prepared segmented echo-planar-imaging [SR-segEPI]) for semiquantitative first-pass myocardial perfusion imaging. Materials and Methods In blood- and tissue-equivalent phantoms the relationship between signal intensity (SI) and contrast-medium concentration was evaluated for the three pulse sequences. In volunteers, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and normalized upslopes (N…