Search results for "quadrupole mass spectrometer"

showing 10 items of 37 documents

The application of phospholipid removal columns and ultra-high performance liquid chromatography-tandem quadrupole mass spectrometry for quantificati…

2016

In this study a robust and sensitive method based on a proposed sample purification procedure, using zirconia-coated Phree™ columns and analysis by ultra-high performance liquid chromatography with triple quadrupole tandem mass spectrometry are presented for the assessment of multi-class antibiotics in farmed fish species. The sample preparation procedure benefited from combined precipitation of proteins and selective removal of phospholipids by Phree™ columns, resulting in a high sensitivity of the method (LOQ 0.3-9mgkg(-1)). The in-house validation results (precision, repeatability, decision limit CCα, detection capability CCβ, etc.) indicate that the elaborated method is fully suitable f…

Clinical BiochemistryPharmaceutical ScienceAquacultureTandem mass spectrometryMass spectrometry01 natural sciencesTrimethoprimAnalytical ChemistryTandem Mass SpectrometryDrug DiscoveryEnrofloxacinmedicinemedia_common.cataloged_instanceAnimalsSample preparationEuropean unionSpectroscopyChromatography High Pressure LiquidPhospholipidsmedia_commonEnrofloxacinChromatographyTandem010405 organic chemistryChemistry010401 analytical chemistryFishesReproducibility of ResultsRepeatabilityDrug Residues0104 chemical sciencesTriple quadrupole mass spectrometerAnti-Bacterial Agentsmedicine.drugFluoroquinolonesJournal of pharmaceutical and biomedical analysis
researchProduct

Mass Spectrometry in Food Quality and Safety

2015

Abstract In recent years, mass spectrometry has gained a wide recognition as a selective and fast technique for the analysis and assessment of a wide range of food products. The state of the art in the determination of safety and quality of food is presented to illustrate the capability of this technique for classification and grading, defect and disease detection, distribution and visualization of chemical attributes, and evaluations of overall quality of meat, fish, fruits, vegetables, and other food products. The features of mass spectrometry for each category were summarized in the aspects of the investigated quality and safety attributes, the used systems (triple quadrupole, quadrupole…

Computer sciencebusiness.industrymedia_common.quotation_subjectMass spectrometrycomputer.software_genreFood safetyOrbitrapTriple quadrupole mass spectrometerlaw.inventionChemometricslawData analysisQuality (business)Data miningFood qualitybusinesscomputermedia_common
researchProduct

Control of pesticide residues by liquid chromatography-mass spectrometry to ensure food safety.

2006

Liquid chromatography-mass spectrometry (LC-MS) has become an invaluable technique for the control of pesticide residues to ensure food safety. After an introduction about the regulations that highlights its importance to meet the official requirements on analytical performance, the different mass spectrometers used in this field of research, as well as the LC-MS interfaces and the difficulties associated with quantitative LC-MS determination, are discussed. The ability to use practical data for quantifying pesticides together with the option of obtaining structural information to identify target and non-target parent compounds and metabolites are discussed. Special attention is paid to the…

Consumer Product SafetyFood securityChromatographyPesticide residueChemistrybusiness.industryFood ContaminationPesticideCondensed Matter PhysicsMass spectrometryFood safetySensitivity and SpecificityGeneral Biochemistry Genetics and Molecular BiologyMass SpectrometryAnalytical ChemistryTriple quadrupole mass spectrometerLiquid chromatography–mass spectrometryConsumer Product SafetyBiochemical engineeringPesticidesbusinessSpectroscopyChromatography High Pressure LiquidFood AnalysisMass spectrometry reviews
researchProduct

Determination of amitraz and its transformation products in pears by ethyl acetate extraction and liquid chromatography-tandem mass spectrometry.

2008

A method has been developed for identification and quantification of the acaricide amitraz and its transformation products, 2,4-dimethylaniline (DMA), 2,4-dimethylformamidine (DMF) and N-2,4-dimethylphenyl-N-methylformamidine (DMPF) in pears. The analytes were extracted using ethyl acetate and anhydrous sodium sulphate. Analysis was performed by liquid chromatography-electrospray tandem mass spectrometry (LC-ESI-MS/MS) in the positive ion mode using a triple quadrupole (QqQ) instrument. Two precursor-product ion transitions were monitored for each compound in the selected reaction monitoring (SRM) mode. The method was validated with pears taken from the orchard before the amitraz treatment …

Detection limitChromatographyMaximum Residue LimitAniline CompoundsToluidinesSulfatesOrganic ChemistrySelected reaction monitoringEthyl acetatePesticide ResiduesReproducibility of ResultsGeneral MedicineAcetatesBiochemistryHigh-performance liquid chromatographySensitivity and SpecificityAnalytical ChemistryTriple quadrupole mass spectrometerPyruschemistry.chemical_compoundchemistryLiquid chromatography–mass spectrometryTandem Mass SpectrometryAmitrazChromatography LiquidJournal of chromatography. A
researchProduct

Optimization of LC–MS/MS using triple quadrupole mass analyzer for the simultaneous analysis of carbosulfan and its main metabolites in oranges

2006

This paper describes an analytical method involving a simple solvent extraction for the simultaneous liquid chromatography coupled to quadrupole tandem mass spectrometry (LC-MS/MS) determination of carbosulfan, its most toxic metabolite--carbofuran--, and its other main metabolites--3-hydroxycarbofuran, 3-ketocarbofuran, 3-hydroxy-7-phenolcarbofuran, 3-keto-7-phenolcarbofuran, 7-phenolcarbofuran and dibutylamine--in oranges. Chromatography was performed on a Zorbax Bonus-RP (150 mm x 2.1 mm, 5 microm). The mobile phase was a ternary gradient water-methanol-acetonitrile with 1.0 mM ammonium acetate at flow rate of 0.2 ml min(-1). The LC separation and MS/MS optimization were studied to selec…

Detection limitChromatographyMetaboliteAnalytical chemistryTandem mass spectrometryBiochemistryAnalytical ChemistryTriple quadrupole mass spectrometerStandard curvechemistry.chemical_compoundchemistryLiquid chromatography–mass spectrometryEnvironmental ChemistrySample preparationCarbosulfanSpectroscopyAnalytica Chimica Acta
researchProduct

Ultra-high performance liquid chromatography-quadrupole time-of-flight mass spectrometry to identify contaminants in water: an insight on environment…

2013

Ultra-high pressure liquid chromatography-quadrupole time-of-flight mass spectrometry (UHPLC-QqTOF-MS) acquiring full scan MS data for quantification, and automatic data dependent information product ion spectra (IDA-MS/MS) without any predefinition of the ions by the user was checked for identifying organic contaminants in water samples. The use of a database with more than 2000 compounds achieved high confidence results for a wide number of contaminants based upon retention time, accurate mass, isotopic pattern and MS/MS library searching. More than 20 contaminants, mostly pharmaceuticals, but also mycotoxins and polyphenols were unambiguously identified. Furthermore, the combination of s…

Detection limitChromatographyTime FactorsChemistryOrganic ChemistryAnalytical chemistryWaterGeneral MedicineContaminationMass spectrometryBiochemistryLibrary searchingAnalytical ChemistryTriple quadrupole mass spectrometerMolecular WeightRiversTandem Mass SpectrometryPrincipal component analysisQuadrupole time of flightUltra high performancePesticidesChromatography High Pressure LiquidWater Pollutants ChemicalJournal of chromatography. A
researchProduct

Identification of unknown pesticides in fruits using ultra-performance liquid chromatography–quadrupole time-of-flight mass spectrometry

2007

Abstract Ultra-high-performance liquid chromatography–quadrupole time-of-flight mass spectrometry (UPLC-QqTOF-MS) is an emerging technique offering more rapid and efficient separation, as well as the possibility to obtain accurate mass measurement and tandem mass spectrometry (MS/MS). This paper deals with the use of UPLC-QqTOF-MS to identify the pesticide residues present in complex pear extracts. Carbendazim, imazalil, and ethoxyquin were successfully identified because of the accurate mass determination of their protonated molecule and their major fragments in the product ion mass spectra. A few plastic and latex additives were also found, most of them probably coming from the packaging …

Detection limitElectrosprayChromatographyCalibration curveChemistryOrganic ChemistryAnalytical chemistryGeneral MedicineTandem mass spectrometryMass spectrometryBiochemistryAnalytical ChemistryTriple quadrupole mass spectrometerLiquid chromatography–mass spectrometryMass spectrumJournal of Chromatography A
researchProduct

Determination of type A and type B trichothecenes in paprika and chili pepper using LC-triple quadrupole-MS and GC-ECD.

2011

There is a need to develop sensitive and accurate analytical methods for determining deoxynivalenol (DON), HT-2 toxin and T-2 toxin in paprika to properly assess the relevant risk of human exposure. An optimized analytical method for determination of HT-2 toxin and T-2 toxin using capillary gas chromatography with electron capture detection and another method for determination of DON by liquid chromatography-mass spectrometry in paprika was developed. The method for determination of HT-2 toxin and T-2 toxin that gave the best recoveries involved extraction of the sample with acetonitrile-water (84:16, v/v), clean-up by solid-phase extraction on a cartridge made of different sorbent material…

Detection limitResidue (complex analysis)ChromatographyChromatography GasElutionChemistryExtraction (chemistry)Mass SpectrometryAnalytical ChemistryTriple quadrupole mass spectrometerT-2 ToxinHumansSample preparationGas chromatographySolid phase extractionCapsicumTrichothecenesChromatography LiquidTalanta
researchProduct

Analysis of fumonisins B1, B2 and B3 in corn-based baby food by pressurized liquid extraction and liquid chromatography/tandem mass spectrometry

2008

A sensitive and reliable method using pressurized liquid extraction (PLE) and liquid chromatography (LC)/electrospray ionization (ESI) tandem mass spectrometry with a triple quadrupole (QqQ) analyzer has been developed for the analysis of fumonisin B(1) (FB(1)), fumonisin B(2) (FB(2)) and fumonisin B(3) (FB(3)) in corn-based baby foods. Influence of several extraction parameters that affect PLE efficiency such as temperature, pressure, solvent extraction, number of cycles and dispersant/clean-up agents were studied. The selected PLE operating method was: 3g of sample was packed into 11 ml stainless-steel cell and fumonisins were extracted with methanol at 40 degrees C, 34 atm in one cycle o…

ElectrosprayChromatographyChemistryElectrospray ionizationOrganic ChemistryExtraction (chemistry)Reproducibility of ResultsGeneral MedicineChemical FractionationFumonisinsZea maysBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryTriple quadrupole mass spectrometerTandem Mass SpectrometryLiquid chromatography–mass spectrometrymedia_common.cataloged_instanceInfant FoodSample preparationEuropean unionChromatography Liquidmedia_commonJournal of Chromatography A
researchProduct

Distribution and fate of perfluoroalkyl substances in Mediterranean Spanish sewage treatment plants.

2014

The concentrations of 21 perfluoroalkyl substances (PFASs: C4-C14, C16, C18 carboxylates, C4, C6-C8 and C10 sulfonates and C8 sulfonamide) were determined in influent, effluent and sludge from 16 different sewage treatment plants (STPs) located in the Ebro (6), Guadalquivir (5), Jucar (2) and Llobregat (3) Rivers, in two consecutive years (2010 and 2011). The analytes were extracted by solid phase extraction (SPE) and determined by Liquid Chromatography triple Quadrupole Mass Spectrometer (LC-QqQ-MS). All samples, except two sludges from Guadalquivir River STPs, were contaminated with at least one PFAS. Perfluorobutanoate (PFBA), perfluoropentanoate (PFPeA) and perfluorooctane sulfonate (L-…

FluorocarbonsEnvironmental EngineeringSewageContaminationPollutionWaste Disposal FluidTriple quadrupole mass spectrometerPerfluorooctanechemistry.chemical_compoundDry weightchemistryWastewaterSpainEnvironmental chemistryEnvironmental ChemistrySewage treatmentSolid phase extractionWaste Management and DisposalEffluentWater Pollutants ChemicalEnvironmental MonitoringThe Science of the total environment
researchProduct