Search results for "radiographic"
showing 10 items of 99 documents
Volume stability of hydroxyapatite and β-tricalcium phosphate biphasic bone graft material in maxillary sinus floor elevation: a radiographic study u…
2015
Objectives The purpose of this study was to confirm volume stability of biphasic calcium phosphate (BCP) through the changes of grafted volume over the time by 3D CT analyzing software program. Patients and Methods Fifteen patients, 16 sinuses who were scheduled a staged implantation through sinus floor elevation (SFE)–lateral window technique from 2009 to 2011 were included in the study. Of the 15 patients, eight were male and seven were female (mean age 50.1). For sinus floor augmentation, BCP with local blood was packed loosely into the maxillary sinus and the grafted site was covered with a collagen membrane. For the evaluation of volume change, 3D CBCT scans were taken five times at pr…
Non-invasive determination of cartilage thickness throughout joint surfaces using magnetic resonance imaging.
1997
Abstract Data on articular cartilage thickness in the living are important for the design of computer models, aimed at preoperatively assessing the effect of surgical procedures on joint contact and load transmission, and for the calculation of cartilage material properties from its deformational behavior as determined during arthroscopy. A non-invasive method for measuring cartilage thickness in living subjects is, however, not available. A technique based on magnetic resonance imaging has therefore been tested for assessing articular cartilage thickness throughout joint surfaces. The accuracy is determined by comparing cartilage thickness maps obtained from three patellar specimens with a…
MAGIC-5: an Italian mammographic database of digitised images for research
2008
The implementation of a database of digitised mammograms is discussed. The digitised images were collected beginning in 1999 by a community of physicists in collaboration with radiologists in several Italian hospitals as a first step in developing and implementing a computer-aided detection (CAD) system. All 3,369 mammograms were collected from 967 patients and classified according to lesion type and morphology, breast tissue and pathology type. A dedicated graphical user interface was developed to visualise and process mammograms to support the medical diagnosis directly on a high-resolution screen. The database has been the starting point for developing other medical imaging applications,…
Focal confluent fibrosis in cirrhotic liver: natural history studied with serial CT.
2009
The objective of this study was to assess the long-term natural history of focal confluent fibrosis in cirrhotic liver with CT.Two radiologists retrospectively reviewed in consensus 118 liver CT examinations in 26 patients (19 men, seven women; age range, 32-68 years; mean age, 50 years) performed over approximately 6 years. Helical CT scans were obtained before and 30-35 and 65-70 seconds after injection of 125-150 mL of contrast medium at a rate of 4-5 mL/s. Proof of cirrhosis was based on liver transplantation (n = 6), biopsy (n = 9), or imaging findings (n = 11). The number, location, and attenuation of fibrotic lesions and presence of trapped vessels were evaluated. Variation of hepati…
Tumori gastrointestinali stromali: Aspetti con tomografia computerizzata multidetettore (40-strati)
2006
Purpose. The purpose of this study was to describe the findings and evaluate the role of multidetector (40-slice) computed tomography (MDCT) in the preoperative assessment of gastrointestinal stromal tumours (GISTs). Materials and methods. Thirteen patients with histologically proven GIST (size: 4-30 cm; mean: 9 cm) underwent 40-slice MDCT after the ingestion of 1,000 ml of water. Images were obtained before and 70 s after intravenous injection of 120 ml of iodinated contrast agent. Two experienced radiologists reviewed the CT findings to evaluate lesion site, size, margins, attenuation, growth pattern, enhancement pattern, ascites, lymphadenopathy, direct invasion to adjacent organs and di…
TC perfusionale nell'ischemia cerebrale acuta: Valore predittivo dei parametri di perfusione cerebrale nel discriminare il tessuto vitale da quello i…
2007
Purpose. The aim of this study was to assess the value of computed tomography (CT) perfusion parameters in differentiating tissue viability in acute stoke patients. Materials and methods. Thirteen patients (mean age 63.3 years) with nonhaemorrhagic stroke underwent multidetector perfusion CT within 3 h of symptom onset. Images were continuously acquired at the basal ganglia over 40 s during injection of 90 ml of iodinated contrast medium injected at a rate of 9 ml/s with a 9-s delay. Z-axis coverage was 20 mm. All patients underwent diffusion-weighted magnetic resonance imaging (DWI) within 12 h of perfusion CT to define the extent of the infarct. Perfusion CT data were analysed in regions …
Virtual Unenhanced Images at Dual-Energy CT: Influence on Renal Lesion Characterization
2019
Background Dual-energy (DE) CT allows reconstruction of virtual noncontrast (VNC) images from a single-phase contrast agent-enhanced examination, potentially reducing the need for multiphasic CT to characterize renal lesions. However, data regarding diagnostic performance of VNC images for the characterization of renal lesions are limited. Purpose To determine whether renal mass CT performed by using VNC images allows for reliable identification of renal lesions and differentiation of contrast-enhanced from unenhanced lesions, compared with unenhanced images. Materials and Methods This is a retrospective study of 293 patients (105 women [mean age, 65 years; age range, 18-91 years] and 188 m…
Efficacy of single-source rapid kV-switching dual-energy CT for characterization of non-uric acid renal stones: a prospective ex vivo study using ant…
2019
Purpose To investigate the accuracy of rapid kV-switching single-source dual-energy computed tomography (rsDECT) for prediction of classes of non-uric-acid stones. Materials and methods Non-uric-acid renal stones retrieved via percutaneous nephrolithotomy were prospectively collected between January 2017 and February 2018 in a single institution. Only stones >= 5 mm and with pure composition (i.e., >= 80% composed of one component) were included. Stone composition was determined using Fourier Transform Infrared Spectroscopy. The stones were scanned in 32-cm-wide anthropomorphic whole-body phantom using rsDECT. The effective atomic number (Zeff), the attenuation at 40 keV (HU40), 70 ke…
[Esophageal digital videofluorography with water siphon test in the post-operative evaluation of the anti-reflux laparoscopic surgery].
2004
Background: In recent years digital videoefluorography (VFG) with water siphon test (WST) has been proposed just for diagnosing biatal bernia and/or gastroesophageal reflux. Patients and Methods: Fifteen patients undergone Laparoscopic Nissen (LN) for complicated GFRD associated to biatal bernia, were referred for VFG and WST in order to evaluate the functional results of surgery. At one- month videofluorographic control thirteen patients had just a minimal prolonged esophageal transit time hut only six of these had an early postoperative dysphagia, whereas at six montJh control the prolonged esophageal transit time was present in three patients two of which complained a very light dysphagi…
Quantitative analysis of emphysema in 3D using MDCT: Influence of different reconstruction algorithms
2008
Abstract Purpose The aim of the study was to compare the influence of different reconstruction algorithms on quantitative emphysema analysis in patients with severe emphysema. Material and methods Twenty-five patients suffering from severe emphysema were included in the study. All patients underwent inspiratory MDCT (Aquilion-16, slice thickness 1/0.8 mm). The raw data were reconstructed using six different algorithms: bone kernel with beam hardening correction (BHC), soft tissue kernel with BHC; standard soft tissue kernel, smooth soft tissue kernel (internal reference standard), standard lung kernel, and high-convolution kernel. The only difference between image data sets was the algorith…