Search results for "range"
showing 10 items of 4508 documents
Thermoelectric properties of CoTiSb based compounds
2009
Several CoTiSb based compounds were synthesized and investigated on their thermoelectric properties. The aim was to improve the thermoelectric properties of CoTiSb by the systematic substitution of atoms or the introduction of additional Co into the vacant sublattice. The solid solutions Co1+xTiSb, Co1?yCuyTiSb and CoTiSb1?zBiz were synthesized. X-ray diffraction was used to investigate the crystal structure. The resistivity, the Seebeck coefficient and the thermal conductivity were determined for all compounds in the temperature range from 2 to 400?K. The highest figure of merit for each solid solution is presented. We were able to improve the figure of merit by a factor of approximately s…
The impact of the EMA change in definition of "dose" on the BCS dose-solubility ratio: a review of the biowaiver monographs.
2013
The Biopharmaceutics Classification System (BCS) defines the solubility characteristics of an active pharmaceutical substance based on its dose-solubility ratio: for highly soluble drugs this ratio is less than 250 mL over a defined pH range. Prior to the revision of the European Medicines Agency (EMA, formerly EMEA) guideline in 2010, the "dose" in this ratio was consistently defined by the US FDA, the EMA, and the WHO biowaiver guidelines as the highest dosage strength. However, in the revised EMA guideline, the dose is defined as the highest single dose administered according to the Summary of Product Characteristics. The new EMA criterion for highly soluble may be closer to the actual c…
Calculation of the chemical potential and the activity coefficient of two layers of CO2 adsorbed on a graphite surface.
2014
We study the adsorption of carbon dioxide at a graphite surface using the new Small System Method, and find that for the temperature range between 300 K and 550 K most relevant for CO2 separation; adsorption takes place in two distinct thermodynamic layers defined according to Gibbs. We calculate the chemical potential and the activity coefficient of both layers directly from the simulations. Based on thermodynamic relations, the entropy and enthalpy of the CO2 adsorbed layers are also obtained. Their values indicate that there is a trade-off between entropy and enthalpy when a molecule chooses for one of the two layers. The first layer is a densely packed monolayer of relatively constant e…
Daily evapotranspiration assessment by means of residual surface energy balance modeling: A critical analysis under a wide range of water availability
2012
Summary An operational use of the actual evapotranspiration assessed by remote sensing approaches requires the integration of instantaneous fluxes to daily values. This is commonly achieved under the hypotheses of daytime self-preservation of evaporative fraction and negligible daily ground heat flux. The aim of this study is to evaluate the effect of these assumptions on estimate daily evapotranspiration over a full phenological cycle, including phases characterized by significant changes both in net radiation and vegetation cover. To assess the reliability of these hypotheses, the observations made by a flux tower, installed within a homogeneous field of cereal located in the valley part …
High-sensitivity troponin T and the risk of recurrent readmissions after hospitalization for acute heart failure
2017
Abstract Objectives High-sensitivity troponin is a biomarker of myocardial damage and is associated with a greater risk of mortality and disease progression in patients with acute heart failure (AHF). However, its relationship with the risk of future readmissions is less known. The aim of this study was to assess the association between ultrasensitive troponin T (TnT-us) values in patients with AHF and the risk of recurrent readmissions in the follow-up. Methods We prospectively included a cohort of 621 consecutive patients with AHF, excluding those patients with acute coronary syndrome. We measured the TnT-us levels obtained during the first medical contact in the emergency department. The…
Acute effects of different foam rolling volumes in the interset rest period on maximum repetition performance
2017
Background - Foam rolling (FR) is a ubiquitous intervention utilised for the purpose of acutely increasing the range of motion without subsequent decreases in performance. Thus, it is commonly used during the periworkout period—that is, prior to, during, or after an athlete's workout.\ud \ud Objective - This study investigated how different FR durations applied to the quadriceps during the interset rest periods affects the numbers of repetitions in the knee extension exercise.\ud \ud Methods - Twenty-five females completed four sets of knee extensions with 10 repetitions of maximum load to concentric failure on four occasions. Between each set, a 4-minute rest interval was implemented in wh…
Enantiospecific Brook Rearrangement of Tertiary Benzylic α-Hydroxysilanes
2018
The Brook rearrangement of simple, chiral tertiary benzylic -hydroxysilanes is presented. The rearrangement followed by proton trapping is enantiospecific and proceeds with inversion of the configuration at the carbon center. Importantly, the [1,2]-Brook rearrangement can be followed by trapping of methyl or allyl electrophiles even in the protic environment, although with minimal retention of chirality.
Stability Analysis of a Linear Parameter Varying Adaptive Output Feedback Control System
2021
Abstract Output feedback control systems often require an adaptive filter for properly shaping the loop transfer function, as certain system plant parameters may be uncertain or varying. This renders the overall closed loop to a linear parameter varying (LPV) system, for which the stability analysis is challenging due to non-trivial dynamics of the adaptation law. This paper develops a stability analysis technique of a feedback controlled oscillatory system. A polytopic overapproximation of the parameter set together with the feasibility of certain LMIs guarantees asymptotic stability of the closed loop. The varying filter parameter is only required to be lower and upper bounded, where the …
Sorption Kinetics of Xenon on MFI-Type Zeolite Molecular Sieves
1990
Kinetic uptake data for xenon adsorbed onto large and uniform silicalite-I crystals are presented over a temperature range of 121 K to 296 K. — Adsorption isotherms and corrected diffusion coefficients derived from the uptake curves are given. The heat of adsorption and activation energy of diffusion were estimated from the plots of reciprocal temperature against the logarithm of equilibrium pressure and corrected diffusion coefficients, respectively. — While the corrected diffusion coefficient is independent of coverage for the higher temperatures, it decreases significantly at the lower temperatures investigated (<170 K) when the limiting adsorption capacity has been reached. — Comparing …
Comparison of the antibacterial effect of uroepithelial cells from healthy donors and children with asymptomatic bacteriuria
1985
Bacterial attachment to uroepithelial cells (UEC) and the effect of UEC on bacterial growth was investigated in 15 healthy persons and 12 patients suffering from asymptomatic bacteriuria (ABU) with recurrent urinary tract infections (UTI). Desquamated UEC and mannose-resistant Escherichia coli were co-cultivated for up to 90 min. While no difference in bacterial adherence was observed between healthy controls and patients, 33.4% of the bacteria attached to normal UEC were found to be dead under microscopic evaluation (acridine orange staining), whereas no killing effect could be observed in patients' UEC 5 min after the onset of incubation. This phenomenon was confirmed by investigating the…