Search results for "ray"

showing 10 items of 8009 documents

Analysis of radiolucent gallstones by computed tomography for in vivo estimation of stone components.

1990

. Successful oral litholytic and other non-operative therapies of gallstones require exact determination of the stone components. Since computed tomography (CT) provides highly sensitive measurement of density, we performed a study to evaluate whether CT measurement of stone density allows a prediction of the composition of radiolucent gallstones. Twenty-eight patients presenting with 29 radiolucent gallbladder (n= 17) or common bile duct stones (n=12) were included. Prior to operative or endo-scopic therapy the attenuation values (Hounsfield Units, HU) were assessed in vivo by CT under standardized conditions (Somatom II, 125 KV, 130 mAs). After surgical or endoscopic stone removal the con…

medicine.medical_specialtySpectrophotometry Infraredmedicine.medical_treatmentRadiodensityClinical BiochemistryPalmitic AcidPalmitic AcidsBiochemistrySensitivity and SpecificityCalcium CarbonateIn vivoCholelithiasisHounsfield scalemedicineHumansCommon bile ductbusiness.industryGallbladderProteinsBilirubinGeneral MedicineGallstonesmedicine.diseaseExtracorporeal shock wave lithotripsyUrsodeoxycholic acidmedicine.anatomical_structureCholesterolRadiologybusinessTomography X-Ray Computedmedicine.drugEuropean journal of clinical investigation
researchProduct

Infrared thermal imaging in the diagnosis of musculoskeletal injuries: a systematic review and meta-analysis.

2014

OBJECTIVE. Musculoskeletal injuries occur frequently. Diagnostic tests using ionizing radiation can lead to problems for patients, and infrared thermal imaging could be useful when diagnosing these injuries. CONCLUSION. A systematic review was performed to determine the diagnostic accuracy of infrared thermal imaging in patients with musculoskeletal injuries. A meta-analysis of three studies evaluating stress fractures was performed and found a lack of support for the usefulness of infrared thermal imaging in musculoskeletal injuries diagnosis.

medicine.medical_specialtyStress fracturesSoft Tissue Injuriesbusiness.industryInfrared RaysPoison controlGeneral Medicinemedicine.diseaseFractures BoneRisk FactorsThermographyMeta-analysisInjury preventionThermographyMedical imagingmedicineInfrared thermal imagingPhysical therapyPrevalenceHumansRadiology Nuclear Medicine and imagingIn patientPractice Patterns Physicians'businessMuscle SkeletalAJR. American journal of roentgenology
researchProduct

New advances in radiomics of gastrointestinal stromal tumors

2020

Gastrointestinal stromal tumors (GISTs) are uncommon neoplasms of the gastrointestinal tract with peculiar clinical, genetic, and imaging characteristics. Preoperative knowledge of risk stratification and mutational status is crucial to guide the appropriate patients' treatment. Predicting the clinical behavior and biological aggressiveness of GISTs based on conventional computed tomography (CT) and magnetic resonance imaging (MRI) evaluation is challenging, unless the lesions have already metastasized at the time of diagnosis. Radiomics is emerging as a promising tool for the quantification of lesion heterogeneity on radiological images, extracting additional data that cannot be assessed b…

medicine.medical_specialtyStromal cellGastrointestinal Stromal TumorsComputed tomographyTexture analysis.Clinical applications03 medical and health sciences0302 clinical medicineMagnetic resonance imagingRadiomicsmedicineMutational statusHumansComputed tomographyGastrointestinal NeoplasmsRadiomicsmedicine.diagnostic_testbusiness.industryGastroenterologyMagnetic resonance imagingMinireviewsGeneral MedicinePrognosisClinical applicationClinical PracticeTexture analysis030220 oncology & carcinogenesisRisk stratification030211 gastroenterology & hepatologyRadiologyDifferential diagnosisGastrointestinal stromal tumorRadiomicbusinessTomography X-Ray Computed
researchProduct

Longitudinal imaging and evaluation of SAH-associated cerebral large artery vasospasm in mice using micro-CT and angiography

2019

Longitudinal in vivo imaging studies characterizing subarachnoid hemorrhage (SAH)-induced large artery vasospasm (LAV) in mice are lacking. We developed a SAH-scoring system to assess SAH severity in mice using micro CT and longitudinally analysed LAV by intravenous digital subtraction angiography (i.v. DSA). Thirty female C57Bl/6J-mice (7 sham, 23 SAH) were implanted with central venous ports for repetitive contrast agent administration. SAH was induced by filament perforation. LAV was assessed up to 14 days after induction of SAH by i.v. DSA. SAH-score and neuroscore showed a highly significant positive correlation (rsp = 0.803, p < 0.001). SAH-score and survival showed a negative sig…

medicine.medical_specialtySubarachnoid hemorrhageBiopsy030204 cardiovascular system & hematologySeverity of Illness IndexMice03 medical and health sciences0302 clinical medicineCerebral vasospasmIn vivomedicineAnimalsVasospasm Intracranialcardiovascular diseasesMicro ctmedicine.diagnostic_testbusiness.industryLarge arteryVasospasmOriginal ArticlesX-Ray MicrotomographyCerebral ArteriesSubarachnoid Hemorrhagemedicine.diseaseImmunohistochemistrynervous system diseasesCerebral AngiographyDisease Models AnimalNeurologyAngiographyFemaleNeurology (clinical)RadiologyCardiology and Cardiovascular MedicinebusinessBiomarkers030217 neurology & neurosurgeryPreclinical imagingJournal of Cerebral Blood Flow & Metabolism
researchProduct

Subarachnoid Hemorrhage Revealing Moyamoya Syndrome in a Patient With May-Hegglin Anomaly.

2017

Etude de cas; Introduction: Moyamoya syndrome is a rare progressive cerebrovascular occlusive disease for which several associated conditions have been described. Case Report: We report the case of a 76-year-old woman with a history of May-Hegglin anomaly who presented with an isolated unusual diffuse headache. Initial laboratory investigations showed only thrombocytopenia (platelet count 95000/mu L). Unenhanced brain computed tomography scan revealed a small subarachnoid hemorrhage in the left frontal lobe. Computed tomography angiography showed occlusion of the terminal portion of the left internal carotid artery (ICA) and narrowing of the terminal portion of the right ICA with abnormal c…

medicine.medical_specialtySubarachnoid hemorrhageMay-Hegglin anomalyHearing Loss SensorineuralOcclusive diseaseLeft frontal lobe030204 cardiovascular system & hematology03 medical and health sciences0302 clinical medicineAneurysm[SDV.MHEP.CSC]Life Sciences [q-bio]/Human health and pathology/Cardiology and cardiovascular systemOcclusionmedicineHumansComputed tomography angiographyAgeddiseasemedicine.diagnostic_testbusiness.industryBrainGeneral MedicineSubarachnoid Hemorrhagemedicine.diseasestrokeThrombocytopeniaStenosismoyamoyaMay–Hegglin anomaly[SDV.NEU]Life Sciences [q-bio]/Neurons and Cognition [q-bio.NC]FemaleNeurology (clinical)RadiologyMoyamoya DiseasebusinessTomography X-Ray Computed030217 neurology & neurosurgery[SDV.MHEP]Life Sciences [q-bio]/Human health and pathologyThe neurologist
researchProduct

An Innovative Weightbearing Device for Weightbearing 3-Dimensional Imaging for Foot and Ankle Surgery Preoperative Planning.

2021

ABSTRACT Three-dimensional preoperative planning has demonstrated multiple surgical advantages. Currently, we cannot carry out preoperative 3-dimensional planning of foot and ankle orthopedics in most hospitals due to the impossibility of performing weightbearing CT imaging. Our objective is to describe and evaluate an innovative accessible, simple, and effective device that simulates standing while in a supine position, to obtain 3-dimensional images supporting bodyweight load with a conventional CT machine. From a group of 30 volunteers, 10 patients were randomly selected and pressure and its distribution were analyzed while in a standing position in both feet. Differences between both fe…

medicine.medical_specialtySupine positionStandard deviationWeight-Bearing03 medical and health sciencesImaging Three-Dimensional0302 clinical medicinemedicineHumansOrthopedics and Sports MedicineOrthodontics030222 orthopedicsPreoperative planningbusiness.industryFoot and ankle surgery030229 sport sciences3D planning foot and ankle CT weightbearingSurgeryThree dimensional imagingmedicine.anatomical_structureStanding PositionOrthopedic surgerySurgeryAnkleAnkleTomography X-Ray ComputedbusinessFoot (unit)
researchProduct

Choice of the operative approach in two cardiosurgical patients assisted by preoperative computed tomography: Case Report

1988

The perioperative course of two patients is exemplified to demonstrate the significance of the preoperative thoracic computed tomography for the selection of a proper surgical approach.

medicine.medical_specialtySurgical approachmedicine.diagnostic_testThoracic computed tomographybusiness.industryComputed tomographyPerioperativeMiddle AgedAortic AneurysmCardiac surgerySurgeryThoracotomyPreoperative CareMyocardial RevascularizationmedicineHumansFemaleRadiologyTomography X-Ray ComputedCardiology and Cardiovascular MedicinebusinessAortaScandinavian Journal of Thoracic and Cardiovascular Surgery
researchProduct

Plain film, CT and MRI sensibility in the evaluation of intraorbital foreign bodies in an in vitro model of the orbit and in pig eyes.

2000

Detection and characterization of intraorbital foreign bodies (IFB) is fundamental in acute trauma setting, preventing inflammatory sequelae or complications related to IFB movements when a MRI study is planned. Papers concerning plain film and CT sensibility in IFB detection show controversial results. For this reason we investigated plain film, CT and MRI sensibility in the evaluation of IFB. For an in vitro model, specimens of dry and fresh wood, glass, iron, plastic and graphite were immersed in animal lard and in a 0.9 % sodium chloride plus 3.5 g/dl human serum albumin solution. Specimens of different size and nature where also implanted into enucleated pig eyes. Air bubbles were intr…

medicine.medical_specialtySwineRadiodensityRadiographyPlain filmEyeSensitivity and SpecificityIn vitro modelmedicineAnimalsHumansRadiology Nuclear Medicine and imagingmedicine.diagnostic_testbusiness.industryUltrasoundMagnetic resonance imagingGeneral MedicineMagnetic Resonance ImagingEye Injuries Penetratingmedicine.anatomical_structureEye Foreign BodiesTomographyRadiologybusinessTomography X-Ray ComputedOrbitOrbit (anatomy)European radiology
researchProduct

Imaging of Ventriculoperitoneal Shunt Complications: Comparison of Whole Body Low-Dose Computed Tomography and Radiographic Shunt Series.

2016

OBJECTIVE To determine diagnostic value and radiation exposure of low-dose computed tomography (LD-CT) compared to radiographic shunt series (SS) for the detection of ventriculoperitoneal (VP) shunt complications. METHODS Fourteen VP shunts were implanted in 7 swine cadavers. Mechanical complications were induced in 50% of VP shunts. Low-dose CT (80 kVp, 10 mAs, Pitch = 1.5) and SS were acquired. Dose area product (DAP) and effective doses for SS and LD-CT were collected. Scoring of diagnostic confidence and blinded readings of SS and CT data were performed. RESULTS The sensitivity of LD-CT was high (0.97; 95% confidence interval, 0.91-1.00) with excellent interobserver agreement (κ = 0.88)…

medicine.medical_specialtySwineRadiographyComputed tomographyRadiation DosageEffective dose (radiation)Sensitivity and SpecificityVentriculoperitoneal Shunt030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinePostoperative ComplicationsRadiation ProtectionmedicineAnimalsRadiology Nuclear Medicine and imagingMedical physicsSingle-Blind MethodWhole Body Imagingmedicine.diagnostic_testbusiness.industryLow doseReproducibility of ResultsRadiation ExposureConfidence intervalRadiographic Image EnhancementDose area productRadiographic Image Interpretation Computer-AssistedTomographybusinessNuclear medicineTomography X-Ray Computed030217 neurology & neurosurgeryShunt (electrical)Journal of computer assisted tomography
researchProduct

Button batteries and typical swallowed foreign bodies can be differentiated in high-resolution X-Rays.

2021

Abstract Background Button battery ingestions have emerged as an increasing medical issue in recent years, especially for children. The frequent use of these energy sources in small appliances and toys is responsible for their ubiquitous occurrence in households. In addition to other possible foreign bodies, button batteries are particularly dangerous as they can cause severe complications in the aerodigestive tract. Objective The study aimed for a detailed analysis of specific radiographic identifiers of button batteries and similarly configured potential esophageal foreign bodies in high-resolution X-ray scans. Methods A selection of potentially hazardous button batteries - in cases of in…

medicine.medical_specialtySwineRadiographyHigh resolutionPoison control03 medical and health sciences0302 clinical medicineElectric Power SuppliesEsophagus030225 pediatricsmedicineAnimalsHumans030223 otorhinolaryngologyChildForeign BodiesButton batterybusiness.industryX-RaysReproducibility of ResultsGeneral Medicinemedicine.diseaseForeign BodiesFrequent useOtorhinolaryngologyPediatrics Perinatology and Child HealthRadiologyForeign bodybusinessEnergy sourceInternational journal of pediatric otorhinolaryngology
researchProduct