Search results for "recording"
showing 10 items of 245 documents
Characteristics of the early flight phase in the Olympic ski jumping competition.
2004
Early flight phase (approximately 40 m) of the athletes participating in the final round of the individual large hill ski jumping competition in Salt Lake City Olympics was filmed with two high-speed pan & tilt video cameras. The results showed that jumpers' steady flight position was almost completed within 0.5s. The most significant correlation with the length of the jump was found in the angle between the skis and body (r=.714, p.001 at 1.1s after the take-off). This particular phase seemed to be important because the ski angle of attack was also related to the jumping distance at the same phase. Although the more upright ski position relative to flight path resulted in longer jumping di…
Documenting carved stones by 3D modelling – Example of Mongolian deer stones
2018
Rock art studies are facing major technical challenges for extensive documentation. Nowadays, recording is essentially obtained from time-consuming tracing and rubbing, techniques that also require a high level of expertise. Recent advances in 3D modelling of natural objects and computational treatment of the modelled surfaces may provide an alternative, and reduce the current documentation bottleneck. The aim of this study is to examine the extent to which such treatments can be applied. The case study presented here concerns the famous deer stones erected by ancient Mongolian nomad populations. The 3D acquisition workflow is based on structure-from-motion, a versatile photogrammetric tech…
Digital liquid-scintillation counting and effective pulse-shape discrimination with artificial neural networks
2014
Abstract A typical problem in low-level liquid scintillation (LS) counting is the identification of α particles in the presence of a high background of β and γ particles. Especially the occurrence of β-β and β-γ pile-ups may prevent the unambiguous identification of an α signal by commonly used analog electronics. In this case, pulse-shape discrimination (PSD) and pile-up rejection (PUR) units show an insufficient performance. This problem was also observed in own earlier experiments on the chemical behaviour of transactinide elements using the liquid-liquid extraction system SISAK in combination with LS counting. α-particle signals from the decay of the transactinides could not be unambigu…
Surface relief grating recording in azobenzene epoxy films
2018
This work has been supported by National research program IMIS2. I would like to thank Larisa Grigorjeva and Aleksejs Zolotarjovs from Institute of Solid state physics, University of Latvia for FTIR measurements.
Azobenzene Containing Low-Molecular Weight Organic Glasses for Optical Recording
2013
Abstract In this work photoinduced processes and holographic surface relief formation in azobenzene containing low- molecular weight organic glasses were studied. The molecular glasses due to trans-cis isomerisation and photo- orientation of molecules possess high sensitivity to the light irradiation and therefore they are promising media for holographic recording. Electric field of linearly polarized light causes an alignment of molecule dipoles perpendicularly to the electric field vector and this process is accompanied by an appearance of photoinduced optical anisotropy in organic glasses. The photoinduced birefringence and dichroism induced by 532 nm light was studied. Holographic recor…
Low light level in vitro monitoring of cellular and antigen-antibody reactions using a photon detection camera system — New perspectives for clinical…
1990
This article briefly describes the use of a photon counting system (ARGUS-100) in the detection of low levels of light. The ARGUS-100 was used in determining ATP in cell sections from tumor tissues and in measuring a luminescence-enhanced immunoluminometric assay, using ferritin as the analyte, based on the luminol-peroxide-4-iodophenol reaction with peroxidase as the enzyme. The aim is not so much the presentation of data, but rather to show the potentials of the photon counting camera in increasing our knowledge of the cellular and subcellular levels, as well as lowering the detection limits in already sensitive systems, such as immunoassays.
Physiological and agonistic behavioural response of Procambarus clarkii to an acoustic stimulus
2012
Summary This study examined the effects of an acoustic stimulus on the haemolymph and agonistic behaviour of the red swamp crayfish Procambarus clarkii. The experiment was conducted in a tank equipped with a video recording system using 6 groups (3 control and 3 test groups) of five adult crayfish (30 specimens in total). After one hour of habituation, the behaviour of the crayfish was monitored for two hours. During the second hour, the animals in the test groups were exposed to a linear sweep (frequency range 0.1-25 kHz; peak amplitude 148 dBrms re 1 µPa at 12 kHz) acoustic stimulus for 30 minutes. Exposure to the noise produced significant variations in haemato-immunological parameters a…
Platelet-endothelial interaction in tumor angiogenesis and microcirculation
2003
Activated platelets release angiogenic growth factors and have therefore been proposed to contribute to tumor angiogenesis within a potentially prothrombotic tumor microcirculation. The aim of the study was to investigate interactions of platelets with the angiogenic microvascular endothelium of highly vascularized solid tumors during growth and in response to endothelial stimulation in comparison with normal subcutaneous tissue. Experiments were performed in the dorsal skinfold chamber preparation of C57BL/6J mice bearing the Lewis lung carcinoma (LLC-1) or methylcholanthrene-induced fibrosarcoma (BFS-1). Fluorescently labeled rolling and adherent platelets, red blood cell velocity, and ve…
Wearable electromyography recordings during daily life activities in children with cerebral palsy.
2020
To test whether wearable textile electromyography (EMG) recording systems may detect differences in muscle activity levels during daily activities between children with cerebral palsy (CP) and age-matched typically developing children.Wearable textile EMG recording systems were used to obtain leg muscle activity in 10 children with spastic CP (four females, six males; mean age 9y 6mo, standard deviation [SD] 2y 4mo, range: 6-13y; Gross Motor Function Classification System [GMFCS] level I and II) and 11 typically developing children (four females, seven males; mean age 9y 9mo, SD 1y 11mo, 7-12y) at rest and while performing seven daily activities.Children with CP showed significantly lower a…
Variance Thresholded EMD-CCA Technique for Fast Eye Blink Artifacts Removal in EEG
2017
International audience; Eye blink (EB) artifacts generated during eye blinks often contaminate electroencephalogram (EEG) signal. Previously Empirical Mode Decomposition (EMD) and Canonical Correlation Analysis (CCA), hybrid EMD-CCA were developed for EB artifact removal in EEG. However, EMD restricts the hybrid algorithm for real time implementation due to its slow processing nature, hence the algorithm has to be enhanced so that it can be a viable solution for real-time EB artifact removal. In this research work, to avoid applying EMD repetitively as and when EB artifacts occur, a method to use EMD minimally is approached. A suitable EB artifact region is detected through a variance thres…