Search results for "refraction"

showing 10 items of 200 documents

Hydrogeological and geotechnical modeling of the foundation soils of Maredolce Lake in Palermo, aided by geophysical surveys

2019

The cultural heritage of Maredolce (Palermo) includes an Arab-Norman castle that originally stood on the shores of an artificial lake carved out of a basin dug out of the calcarenite and filled with water thanks to the channeling of the springs of San Ciro upstream. Subsequently, the lowering of the water table and the high hydraulic permeability of the outcropping rocks caused the lake to dry up. Recently, a project of enhancement of the cultural heritage required the restoration of the lake. The geophysical study presented here, including the integrated use of different techniques such as electrical and seismic tomography, Multichannel Analysis of the Surface Waves and ambient vibration r…

Seismic Refraction TomographyHVSRSettore GEO/11 - Geofisica ApplicataElectrical Resistivity TomographyMaredolce
researchProduct

Multivariate modelling of geophysical tomography data to identify a tectonized area

2018

An integrated analysis approach, based on geological investigations and 2D high-resolution shallow geophysical data, was proposed along a slope in the Bellolampo landfill area (Palermo, Italy) where the presence of a fault zone was hypothesized. Geophysical surveys included electrical resistivity tomography (ERT), induced polarization tomography (IPT) and seismic refraction tomography (SRT) techniques. The inversion of single geophysical parameter often does not allow to justify the complexity of the subsoil structures. The most appropriate solution should be to add additional physical or geological information so to get a constrained geological model. However, it is not at all easy to work…

Settore GEO/02 - Geologia Stratigrafica E SedimentologicaSettore GEO/11 - Geofisica ApplicataElectrical resistivity tomography seismic refraction tomography còluster analysis tectonized area Bellolampo
researchProduct

Statistical approach for cavity detection using seismic refraction and electrical resistivity data

2017

To test limitations and effectiveness of seismic tomography when coupled to geoelectrical technique for cavity detection 2D synthetic models were used. Synthetic models were created with different number of cavity and blocks of highly cohesive lithological material (high seismic velocity and resistivity values). A modified version of multiple gradient (Martorana et al., 2016) has been used for electrical sequence. The cluster analysis performed on static units defined by electrical resistivity values, P wave velocities, and seismic density on coincident sections, allowed to interpret subsoil structures. The use of the non-hierarchical clustering algorithm has been chosen because it is less …

Settore GEO/11 - Geofisica Applicataseismic refraction tomography alectrical resistivity tomography cavity cluster analysis
researchProduct

A crustal seismic profile across Sicily

2011

Abstract A crustal reflection seismic profile, more than 100 km long, was recorded across central Sicily, from the Tyrrhenian shore to the Sicily Channel, to understand the deep structures and the collision mechanisms between Europe and Africa and the subsequent geodynamic evolution. The profile was acquired using explosive sources and 240 active channels recorded by a Sercel 408-XL, 24 bits A/D converter, with a 12 km spread and a 24-fold coverage. The data were processed following a non-conventional procedure in order to preserve the relative amplitudes of the reflections and to better investigate the Sicily deep structures down to the Moho. The main highlighted structures are the dramati…

Shoregeographygeography.geographical_feature_categorySettore GEO/02 - Geologia Stratigrafica E SedimentologicaSettore GEO/03 - Geologia StrutturaleTrough (geology)CrustNappeGeophysicsCrustal seismic Reflection Refraction tomography Sicily Caltanissetta BasinSettore GEO/11 - Geofisica ApplicataForeland basinGeologySeismologyEarth-Surface Processes
researchProduct

3D reconstruction of transparent objects exploiting surface fluorescence caused by UV irradiation

2010

In this paper, we present a novel approach exploiting fluorescence imaging to estimate the shape of transparent objects. Classical inspection systems require users to coat transparent objects with some powder before measurement. Methods suggested in literature through non contact measurement do not effectively deal with the refraction problem, thus, providing inaccuracies. The proposed method handles the scanning of transparent objects without using any powder and solving the refraction problem using UV environment. A classical triangulation method based on stereovision scheme using fixed stereoscopic visible range cameras with a fixed UV (Ultra Violet) laser source is implemented. Transpar…

Surface (mathematics)Materials sciencebusiness.industry3D reconstructionTriangulation (computer vision)StereoscopyIterative reconstructionFluorescenceRefractionlaw.inventionlawComputer visionIrradiationArtificial intelligencebusiness2010 IEEE International Conference on Image Processing
researchProduct

Refractive index and equilibrium water content of conventional and silicone hydrogel contact lenses

2006

Prova tipográfica (In Press)

Traditional handheld refractometerMaterials scienceSiliconesRefractive index02 engineering and technologyRefraction Ocular03 medical and health scienceschemistry.chemical_compound0302 clinical medicineOpticsSiliconeRefractometerHumanssilicone hydrogelCLR 12-70Siloxane hydrogelScience & TechnologyEquilibrium water contentbusiness.industryWaterHydrogelsHEMAEquipment DesignContact Lenses Hydrophilic021001 nanoscience & nanotechnologyAtago N-2ESensory SystemsContact lensOphthalmologyRefractometrysoft contact lenschemistrySiloxaneSelf-healing hydrogels030221 ophthalmology & optometry0210 nano-technologybusinessRefractive indexRefractometryconventional hydrogelOptometryBiomedical engineering
researchProduct

Presbyopia and the aging eye: Existing refractive approaches and their potential impact on dry eye signs and symptoms.

2020

Every part of the human body is subject to aging, including the eye. Increased prevalence of dry eye disease with age is widely acknowledged: aging threatens ocular surface homeostasis, altering the normal functioning of the lacrimal functional unit and potentially leading to signs and symptoms of dry eye. Parallelly, two additional degenerative processes take place within the crystalline lens, leading to presbyopia and cataractogenesis. With continuously increasing life expectancies both conditions are expected to impact society further. Correction strategies for presbyopia and cataracts either directly or indirectly challenge ocular surface additionally. On one hand, contact lens presbyop…

Ulls Acomodació i refracciómedicine.medical_specialtyAginggenetic structuresmedicine.medical_treatmentSigns and symptomsRefraction Ocular03 medical and health sciences0302 clinical medicineCataractsOphthalmologyRefractive surgeryCorneamedicineHumansCorneal epitheliumAgedPotential impactbusiness.industryGeneral MedicinePresbyopiaPresbyopiamedicine.diseaseeye diseasesÒptica Aparells i instrumentsContact lensOphthalmologymedicine.anatomical_structureTears030221 ophthalmology & optometryDisease ProgressionDry Eye Syndromessense organsbusiness030217 neurology & neurosurgeryOptometryContact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

Comparison of higher order aberrations measured by NIDEK OPD-Scan dynamic skiascopy and Zeiss WASCA Hartmann-Shack aberrometers.

2008

<h4>PURPOSE</h4><p>To compare the measurement of wavefront aberrations in non-cyclopleged human eyes with Hartmann-Shack and dynamic skiascopy wavefront analyzers.</p> <h4>METHODS</h4><p>Eighty eyes of 40 healthy young adults (19 men, 21 women; mean age 20.8±2.5 years) with refractive errors ranging from +1.50 to –9.75 diopters (D) sphere and up to 1.75 D cylinder (mean spherical equivalent refraction –2.12±2.69 D) were examined with the Zeiss/Meditec WASCA and NIDEK OPD-Scan wavefront analyzers and with the Nippon SRW5000 binocular, open-field autorefractor without the instillation of antimuscarinic agents. Three measurements were taken with each s…

WavefrontAdultMalegenetic structuresbusiness.industrymedicine.medical_treatmentReproducibility of ResultsClinical settingsDiagnostic Techniques OphthalmologicalRefraction OcularRefractive Errorseye diseasesOphthalmologyAberrations of the eyeOpticsRefractive surgerymedicineOptometryHumansSurgeryFemalebusinessNatural stateMathematicsWavefront analysisJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct

Optical quality comparison between 2 collagen copolymer posterior chamber phakic intraocular lens designs

2014

Purpose To compare the optical quality in vitro of 2 designs of the Visian Implantable Collamer Lens phakic intraocular lens (pIOL) for different powers and optical apertures. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The Nimo TR1504 deflectometry device was used to measure the V4c pIOL, which has a smaller optic diameter, and the V5 pIOL, which has a larger optic diameter. The pIOLs were measured for −3.00 diopters (D), −6.00 D, −9.50 D, and −10.50 D at different optical apertures from 3.00 to 6.00 mm depending on the IOL power and model. The root mean square of higher-order aberrations (RMS HOAs) was analyzed. The Strehl ratio, point-spread functi…

WavefrontOptics and PhotonicsPhakic Intraocular LensesMaterials sciencePolymersApertureZernike polynomialsbusiness.industryStrehl ratioPupilProsthesis DesignRefraction OcularPhakic intraocular lensSensory SystemsRoot mean squareOphthalmologySpherical aberrationsymbols.namesakeOpticssymbolsHumansSurgeryCollagenbusinessDioptreJournal of Cataract and Refractive Surgery
researchProduct

In vitro optical performance of nonrotational symmetric and refractive-diffractive aspheric multifocal intraocular lenses: impact of tilt and decentr…

2012

Purpose To evaluate the optical quality of Acrysof Restor SN6AD1 refractive–diffractive +3.00 D and Lentis Mplus LS-312 nonrotational symmetric +3.00 D aspheric multifocal intraocular lenses (IOLs) and analyze the effect of tilt and decentration. Setting University of Valencia, Valencia, and University of Murcia, Murcia, Spain. Design Experimental study. Methods An artificial model eye was used to measure wavefront aberrations of both IOL models. The modulation transfer function (MTF) and point-spread function (PSF) were calculated for a 5.0 mm pupil and under 5 situations: centered, 0.2 mm and 0.4 mm decentered, and 2 degrees and 4 degrees tilted. Results The refractive–diffractive IOL had…

WavefrontPhysicsLenses IntraocularOptics and Photonicsbusiness.industryAberrometryMultifocal intraocular lensModels TheoreticalArtificial Lens Implant MigrationProsthesis DesignRefraction OcularRefractionSensory SystemsCycles per degreeOphthalmologyOpticsTilt (optics)Optical transfer functionAberrometryOptometryHumansSurgerySpatial frequencybusinessJournal of cataract and refractive surgery
researchProduct