Design and simulation of efficient combinational circuits based on a new XOR structure in QCA technology

2021

AbstractQuantum-dot cellular automata (QCA), due to its unique characteristics like low power consumption, nanoscale design, and high computing speed is considered as an emerging technology, and it can be used as an alternative for CMOS technology in circuit design for quantum computers in the near future. XOR gate has many applications in the design of digital circuits in QCA. In this paper, an efficient novel structure of XOR gate is proposed in QCA. Also, a novel 1-bit comparator circuit, 1-bit full adder, binary to gray and gray to binary convertor code based on the proposed XOR is designed and simulated using QCADesigner 2.0.3. The simulation results demonstrated that the proposed stru…

full adderAdderComparatorComputer scienceCircuit designelektroniset piiritBinary numberHardware_PERFORMANCEANDRELIABILITYElectronic engineeringHardware_INTEGRATEDCIRCUITSElectrical and Electronic EngineeringHardware_ARITHMETICANDLOGICSTRUCTURESXOR gateCombinational logicDigital electronicsbusiness.industrykvanttitietokoneetkvanttilaskentaconverterAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsCMOSsoluautomaatitbusinessquantum-dot cellular automataXOR gatecomparatorHardware_LOGICDESIGN
researchProduct

A Logic Fuzzy Model for Evaluation of the Railway Station’s Practice Capacity in Safety Operating Conditions

2013

Abstract The practice capacity of a railway junction depends, in addition to the effective operation’s conditions, by the potential risk factors related to the design plan of the railway station. With the aim of an approach based on the “fuzzy sets” it is possible to determine the numeric value of the practice capacity by the logic - qualitative relations between the features of the railway junction and the potential risk factors. This methodology permits to try out the absolute value of a suitable vector β, (less then the unit) for the utilization of the theoretic capacity in conditions of maximum reliability of the system related to the aspect of safety (technique “fail safe”).

fuzzy setEngineeringbusiness.industryFuzzy setFuzzy modelDesign planAbsolute value (algebra)railway stationsoperative conditionsReliability engineeringpractice capacitylcsh:TA1-2040railway stations practice capacity fuzzy setSettore ICAR/04 - Strade Ferrovie Ed AeroportiFail-safeNumeric Valuelcsh:Engineering (General). Civil engineering (General)businessReliability (statistics)Civil and Structural EngineeringRailway junctionArchives of Civil Engineering
researchProduct

Preliminary magnetic resonance relaxometric analysis of Fricke gel dosimeters produced with polyvinyl alcohol and glutaraldehyde

2017

This work describes the preliminary analysis of Fricke gels dosimeters characterized by a new formulation making use of a matrix of polyvinyl alcohol cross-linked by adding glutaraldehyde and analyzed by means of nuclear magnetic resonance relaxometry. In previous optical studies, these gels have shown promising dosimetric features in terms of photon sensitivity and low diffusion of ferric ions produced after irradiation. In this work, we used a portable nuclear magnetic resonance relaxometer to measure the relaxation times (which are important for dosimetric applications) of these gel materials. For this purpose, we performed a study for optimizing the acquisition parameters with a nuclear…

gelMaterials science02 engineering and technology01 natural sciencesPolyvinyl alcoholchemistry.chemical_compound0103 physical sciencesmedicinelcsh:Nuclear and particle physics. Atomic energy. RadioactivityFricke gelSafety Risk Reliability and QualityradiotherapySettore CHIM/02 - Chimica FisicaDosimetermedicine.diagnostic_testdosimetry010308 nuclear & particles physicsSettore FIS/01 - Fisica SperimentaleMagnetic resonance imaging021001 nanoscience & nanotechnologySettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Dosimetry Gel NMR PVA GTA radiotherapynuclear magnetic resonancepolyvinyl alcoholNuclear Energy and Engineeringchemistryglutaraldehydelcsh:QC770-798Glutaraldehyde0210 nano-technologySettore MED/36 - Diagnostica Per Immagini E RadioterapiaDosimetry; Gel; Glutaraldehyde; Nuclear magnetic resonance; Polyvinyl alcohol; RadiotherapyNuclear chemistryNuclear Technology and Radiation Protection
researchProduct

Psychometric properties of the MOBITEC-GP mobile application for real-life mobility assessment in older adults

2022

Aim of this study was to test the reliability and validity of the life-space measures and walking speed delivered by the MOBITEC-GP app. Participants underwent several supervised walking speed assessments as well as a 1-week life-space assessment during two assessment sessions 9 days apart. Fifty-seven older adults (47.4% male, mean age= 75.3 (±5.9) years) were included in the study. The MOBITEC-GP app showed moderate to excellent test-retest reliability (ICCs between 0.584 and 0.920) and validity (ICCs between 0.468 and 0.950) of walking speed measurements of 50 meters and above and of most 1-week life-space parameters, including life-space area, time spent out-of-home, and action range. T…

geographic information systemsSAMPLEactivity space11476 Digital Society InitiativeagingQUESTIONNAIREUFSP13-4 Dynamics of Healthy Aging2909 Gerontologysmartphoneinertial sensorskävelyälypuhelimetLIFE-SPACE MOBILITY10122 Institute of GeographyikääntyminenPEOPLEpaikkatietojärjestelmätEarth and Environmental SciencesRELIABILITYaging; gait speed; activity space; smartphone; geographic information systems; inertial sensors910 Geography & travelCOMORBIDITYgait speedGerontology
researchProduct

A fuzzy-based tool for modelization and analysis of the vulnerability of aquifers: a case study

2005

Abstract A fuzzy-based tool, called FUZZY-SRA (Fuzzy Spatial Reliability Analysis), is used for realizing a more “reliable” study of the values of the final parameters concerning the vulnerability of aquifers located in the territory of Cava de' Tirreni, city in the district of Salerno (Italy). The SINTACS method is adopted for evaluating the involved parameters and these evaluations are modelled from attributes represented from triangular fuzzy numbers which supply the overall final information if combined with suitable algebraic operations. The tool FUZZY-SRA is implemented inside a GIS (Geographical Information Systems) software.

geographygeography.geographical_feature_categoryOperations researchbusiness.industryComputer scienceGeographic Information SystemApplied MathematicsSpatial analysisAquiferFuzzy logicTheoretical Computer ScienceReliability engineeringSoftwareArtificial IntelligenceAlgebraic operationGeographic Information SystemsInformation systemFuzzy numberbusinessFuzzy numberSoftwareReliability (statistics)Vulnerability (computing)International Journal of Approximate Reasoning
researchProduct

A Simulation Analysis for Assessing the Reliability of AC/DC Hybrid Microgrids - Part II: Port Area and Residential Area

2021

This paper reports the second part of a simulation study with the aim of evaluating the ability of two portions of a hybrid AC/DC MV/LV network in maintaining their operation in off-grid mode during the loss of the main AC grid due to a failure. In particular, this paper follows a dual purpose: first, it analysis two microgrids in a residential area and a port zone capability of operating in islanded mode, applying a probabilistic approach, while there is different energy use cases, and second is to evaluate some reliability indicators.

geographygeography.geographical_feature_categoryreliabilityComputer scienceAC/DC microgridsProbabilistic logicMode (statistics)Port (circuit theory)securityGridcontinuityResidential areaReliability engineeringSettore ING-IND/33 - Sistemi Elettrici Per L'EnergiaflexibilityReliability (semiconductor)Use caseEnergy (signal processing)
researchProduct

SEU characterization of commercial and custom-designed SRAMs based on 90 nm technology and below

2020

International audience; The R2E project at CERN has tested a few commercial SRAMs and a custom-designed SRAM, whose data are complementary to various scientific publications. The experimental data include low- and high-energy protons, heavy ions, thermal, intermediate- and high-energy neutrons, high-energy electrons and high-energy pions.

high-energy protonsCOTS[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]käyttömuistitNuclear TheoryElectronHardware_PERFORMANCEANDRELIABILITY01 natural sciences7. Clean energyIonelektroniikkakomponentitNuclear physicsCross section (physics)Pion0103 physical sciencesNeutronionisoimaton säteilyStatic random-access memory010306 general physicsheavy ionsNuclear Experimentlow-energy protonsPhysicsLarge Hadron Collidercross section010308 nuclear & particles physicsionisoiva säteilyelectronsneutronsmuistit (tietotekniikka)SRAMCharacterization (materials science)säteilyfysiikkapionsSEU
researchProduct

New applications of zoobenthos measurements for risk assessment of chemicals in aquatic ecosystems

2015

Artikkeliväitöskirja. Yhteenveto-osa ja viisi artikkelia. (Artikkelit eivät avoimesti saatavilla.) Article dissertation. An introduction and five articles (not available in this version). Benthic animals in aquatic ecosystems suffer from various anthropogenic pollutants. A challenge in risk assessment of chemicals in aquatic ecosystems (i.e. ecological risk assessment) has been to balance cost-efficiency and effectiveness in detecting early warning signals of chemicals. In this study, hyperspectral imaging and behavioural measurements were evaluated as novel applications for detecting chemical effects on benthic animals, and the reliability of the incidence of chironomid morphological defor…

hyperspectral imagingeläinten käyttäytyminenympäristön tilaraskasmetallitinterrater reliabilityepämuodostumathaitalliset aineetympäristöhaitatkadmiumvesieläimistöympäristön saastuminenvesien saastuminenfungispektrikuvausvesiekosysteemitriskinarviointivesistövaikutuksetbehaviourmorphological deformitiesmittausmenetelmätpohjaeläimistöympäristövaikutuksetkemikaalitympäristövaikutusten arviointiarviointibenthic macroinvertebratesbioindikaattorit
researchProduct

Statements About the Pervasiveness of Behavior Require Data About the Pervasiveness of Behavior

2020

Despite recent close attention to issues related to the reliability of psychological research (e.g., the replication crisis), issues of the validity of this research have not been considered to the same extent. This paper highlights an issue that calls into question the validity of the common research practice of studying samples of individuals, and using sample-based statistics to infer generalizations that are applied not only to the parent population, but to individuals. The lack of ergodicity in human data means that such generalizations are not justified. This problem is illustrated with respect to two common scenarios in psychological research that raise questions for the sorts of the…

individualitypervasivenessvaliditylcsh:BF1-990Population050109 social psychologySample (statistics)Review050105 experimental psychologyPsychologyMainstream0501 psychology and cognitive scienceseducationGeneral PsychologyReliability (statistics)Analysis methodReplication crisiseducation.field_of_studyPsychological research05 social sciencesCognitionlcsh:PsychologyergodicityPsychologyscientific practiceCognitive psychologyFrontiers in Psychology
researchProduct

Metrological performances of voltage and current instrument transformers in harmonics measurements

2018

In the new electrical system scenario, the increasing presence of non-linear loads and renewable energy sources makes the measurement of harmonics an essential task. The accuracy of harmonic measurement firstly depends on the used instrument transformers for voltage and current sensing. Since the behavior of instrument transformers in non-sinusoidal conditions is not always well defined, this paper presents an experimental study on the metrological performances of current and voltage instrument transformers (CTs and VTs) in the presence of harmonics. Proper tests procedures are defined and measurement setups are developed for both CTs and VTs calibration. The analysis is carried out by usin…

instrument transformers020209 energy02 engineering and technologyInstrument TransformerHarmonic analysispower system meaurementsPhase AngleDistortionharmonics0202 electrical engineering electronic engineering information engineeringCalibrationElectronic engineeringMedicineSafety Risk Reliability and QualityInstrumentationbusiness.industry020208 electrical & electronic engineeringHarmonicPower System MeasurementcalibrationCurrent transformerMetrologyHarmonicsHarmonicbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltage