Search results for "repeatability"

showing 10 items of 214 documents

Rugged Large Volume Injection for Sensitive Capillary LC-MS Environmental Monitoring

2017

A rugged and high throughput capillary column (cLC) LC-MS switching platform using large volume injection and on-line automatic filtration and filter back-flush (AFFL) solid phase extraction (SPE) for analysis of environmental water samples with minimal sample preparation is presented. Although narrow columns and on-line sample preparation are used in the platform, high ruggedness is achieved e.g. injection of 100 non-filtrated water samples would did not result in a pressure rise/clogging of the SPE/capillary columns (inner diameter 300 µm). In addition, satisfactory retention time stability and chromatographic resolution were also features of the system. The potential of the platform for …

Resolution (mass spectrometry)Capillary actionAnalytical chemistry02 engineering and technologycapillary LC01 natural scienceslaw.inventionlcsh:ChemistrylawLiquid chromatography–mass spectrometrySample preparationSolid phase extractionon-line solid phase extractionFiltrationOriginal ResearchDetection limitChromatographyChemistry010401 analytical chemistryGeneral ChemistryRepeatability021001 nanoscience & nanotechnology0104 chemical sciencespharmaceutical productsChemistrylcsh:QD1-999column switchinglarge volume injection0210 nano-technologyFrontiers in Chemistry
researchProduct

Sampling and repeatability in the evaluation of hepatitis C virus genetic variability.

2003

Among the experimental techniques available to study the genetic variability of RNA virus populations, the most informative involve reverse transcription (RT), amplification, cloning and sequencing. The effects of several aspects of these techniques on the estimation of genetic variability in a virus population were analysed. Hepatitis C virus populations from four patients were examined. For each patient, ten series of data derived from independent PCR amplifications of a single RT reaction were obtained. The sample size of each data set was 10 sequences (in nine series) and 100 sequences (in one series). An additional data set derived from an independent RT reaction (about 10 sequences) p…

Geneticseducation.field_of_studyPhylogenetic treebiologyTranscription GeneticPopulationMolecular Sequence DataGenetic VariationRNA virusNucleic acid amplification techniqueRepeatabilityHepacivirusbiology.organism_classificationHaplotypesSample size determinationVirologyGenetic variationHumansGenetic variabilityeducationNucleic Acid Amplification TechniquesPhylogenyThe Journal of general virology
researchProduct

Highly sensitive olfactory biosensors for the detection of volatile organic compounds by surface plasmon resonance imaging

2018

International audience; Nowadays, monitoring of volatile organic compounds (VOCs) is very important in various domains. In this work, we aimed to develop sensitive olfactory biosensors using odorant binding proteins (OBPs) as sensing materials. Three rat OBP3 derivatives with customized binding properties were designed and immobilized on the same chip for the detection of VOCs in solution by surface plasmon resonance imaging (SPRi). We demonstrated that the proteins kept their binding properties after the immobilization under optimized conditions. The obtained olfactory biosensors exhibited very low limits of detection in both concentration (200pM of beta-ionone) and in molecular weight of …

volatile organic compoundConformational change[SDV.BIO]Life Sciences [q-bio]/BiotechnologyOdorant bindingBiomedical EngineeringBiophysicsBiosensing Techniques02 engineering and technologyReceptors Odorant01 natural sciencesHexanal[SPI]Engineering Sciences [physics]chemistry.chemical_compoundElectrochemistryAnimalsVolatile organic compoundComputingMilieux_MISCELLANEOUSDetection limitchemistry.chemical_classificationVolatile Organic CompoundsChromatographyChemistry010401 analytical chemistryGeneral MedicineRepeatabilitySurface Plasmon Resonance021001 nanoscience & nanotechnologyRats0104 chemical sciencesSmellsurface plasmon resonance imagingofactory biosensor0210 nano-technologySelectivityBiosensorodorant binding proteinsBiotechnologyBiosensors and Bioelectronics
researchProduct

Ionic liquid-based single-drop microextraction followed by liquid chromatography-ultraviolet spectrophotometry detection to determine typical UV filt…

2009

Abstract A user-friendly and inexpensive ionic liquid-based single-drop microextraction (IL-SDME) procedure has been developed to preconcentrate trace amounts of six typical UV filters extensively used in cosmetic products (i.e., 2-hydroxy-4-methoxybenzophenone, isoamyl 4-methoxycinnamate, 3-(4′-methylbenzylidene)camphor, 2-ethylhexyl 2-cyano-3,3-diphenylacrylate, 2-ethylhexyl 4-dimethylaminobenzoate and 2-ethylhexyl 4-methoxycinnamate) from surface water samples prior to analysis by liquid chromatography-ultraviolet spectrophotometry detection (LC-UV). A two-stage multivariate optimization approach was developed by means of a Plackett–Burman design for screening and selecting the significa…

Detection limitAnalyteChromatographyCentral composite designmedicine.diagnostic_testAnalytical chemistryRepeatabilityAnalytical Chemistrychemistry.chemical_compoundchemistryIonic strengthSpectrophotometryIonic liquidmedicineSample preparationTalanta
researchProduct

Mycotoxin Analysis of Human Urine by LC-MS/MS: A Comparative Extraction Study

2017

The lower mycotoxin levels detected in urine make the development of sensitive and accurate analytical methods essential. Three extraction methods, namely salting-out liquid–liquid extraction (SALLE), miniQuEChERS (quick, easy, cheap, effective, rugged, and safe), and dispersive liquid–liquid microextraction (DLLME), were evaluated and compared based on analytical parameters for the quantitative LC-MS/MS measurement of 11 mycotoxins (AFB1, AFB2, AFG1, AFG2, OTA, ZEA, BEA, EN A, EN B, EN A1 and EN B1) in human urine. DLLME was selected as the most appropriate methodology, as it produced better validation results for recovery (79–113%), reproducibility (RSDs < 12%), and repeatability (RSDs…

AdultHealth Toxicology and MutagenesisLiquid-Liquid Extractionlcsh:MedicineUrineToxicology01 natural sciencesArticlechemistry.chemical_compound0404 agricultural biotechnologyTandem Mass SpectrometrymycotoxinsLc ms msHealthy volunteersHumansLC-MS/MSMycotoxinReproducibilityChromatographymycotoxins; urine; optimization; method validation; LC-MS/MSlcsh:R010401 analytical chemistryExtraction (chemistry)method validation04 agricultural and veterinary sciencesRepeatability040401 food scienceurine0104 chemical scienceschemistryExtraction methodsoptimizationChromatography LiquidToxins
researchProduct

Simultaneous screening and quantification of aminoglycoside antibiotics in honey using mixed-mode liquid chromatography with quadrupole time-of-fligh…

2018

An analytical method based on liquid chromatography with quadrupole time-of-flight mass spectrometry has been developed for the simultaneous determination of six aminoglycoside antibiotics in honey. The sample pretreatment included extraction with aqueous trichloroacetic acid followed by solid-phase extraction on Strata-X polymeric reversed phase cartridges. Liquid chromatography separation was performed on an Obelisc R zwitterionic type mixed-mode column. An ionBooster™ heated electrospray source was used and showed enhanced ionization efficiency in comparison to a conventional electrospray source. The observed signal enhancement ranged from 3- (neomycin) to 16-fold (gentamicin C1). A data…

Spectrometry Mass Electrospray IonizationElectrosprayTime FactorsElectrospray ionizationDrug Evaluation PreclinicalFiltration and Separation02 engineering and technologyMass spectrometry01 natural sciencesMass SpectrometryAnalytical ChemistryIonizationChromatographyChemistry010401 analytical chemistryAminoglycosideExtraction (chemistry)HoneyRepeatability021001 nanoscience & nanotechnologyAnti-Bacterial Agents0104 chemical sciencesAminoglycosidesGentamicin C10210 nano-technologyChromatography LiquidJournal of Separation Science
researchProduct

Precision of a commercial hartmann-shack aberrometer: limits of total wavefront laser vision correction.

2012

Purpose To assess the intrasession and intersession precision of higher-order aberrations (HOAs) measured using a commercial Hartmann-Shack wavefront sensor (Zywave; Bausch & Lomb) in refractive surgery candidates. Design Prospective, experimental study of a device. Methods To analyze intrasession repeatability, 1 experienced examiner measured 30 healthy eyes 5 times successively. To study intersession reproducibility, the same clinician obtained measurements from another 30 eyes in 2 consecutive sessions at the same time of day 1 week apart. Results For intrasession repeatability, excellent intraclass correlation coefficients (ICCs) were obtained for total ocular aberrations, total HOAs, a…

AdultMaleCorneal Wavefront AberrationIntraclass correlationZernike polynomialsmedicine.medical_treatmentRefraction Ocularsymbols.namesakeYoung AdultOpticsRefractive surgeryAberrometrymedicineHumansProspective StudiesMathematicsWavefrontObserver VariationReproducibilitybusiness.industryAberrometryReproducibility of ResultsRepeatabilityWavefront sensorMiddle AgedRefractive ErrorsOphthalmologysymbolsOptometryFemalebusinessAmerican journal of ophthalmology
researchProduct

Lauroyl peroxide as thermal initiator of lauryl methacrylate monolithic columns for CEC

2008

The preparation of lauryl methacrylate (LMA)-based monolithic columns for CEC using lauroyl peroxide (LPO) as thermal initiator of polymerization has been investigated. The influence of initiator amount and composition of porogenic solvent on the physical and electrochromatographic properties of the resulting LMA-based monoliths was evaluated. A comparison with LMA-based columns thermally polymerized with AIBN was performed. At a given porogenic solvent composition, LMA stationary phases initiated with LPO showed higher permeabilities and better efficiency values than those prepared using AIBN as initiator. The optimum polymerization mixture found for LPO initiator provided a minimum plate …

chemistry.chemical_classificationLipid PeroxidesChromatographyFree RadicalsPolymersChemistryClinical BiochemistryTemperatureLauric AcidsPolycyclic aromatic hydrocarbonRepeatabilityLauroyl peroxideBiochemistryAnalytical ChemistrySolventPolymerizationCapillary ElectrochromatographyNitrilesThermalMethacrylatesSolvent compositionLauryl methacrylateNuclear chemistryELECTROPHORESIS
researchProduct

Optimization of transmission near infrared spectrometry procedures for quality control of pesticide formulations

2006

The use of different response functions to be optimized in the frame of the use of near infrared spectrometry for quality control of active principles in agrochemical formulations has been evaluated. Both, simple functions, based on parameters like sensitivity, repeatability, accuracy, signal to noise ratio, limit of detection or sample throughput, and a complex function, considering all the aforementioned aspects, were employed in the development of a new method for Iprodione determination in agrochemicals. Optimization strategies were based on the previous screening of the most important instrumental factors like number of cumulated scans, nominal resolution, mirror velocity and zero fill…

Detection limitResolution (mass spectrometry)ChemistryRepeatabilityFactorial experimentBiochemistryAnalytical ChemistrySignal-to-noise ratioStatisticsCalibrationEnvironmental ChemistrySensitivity (control systems)Biological systemThroughput (business)SpectroscopyAnalytica Chimica Acta
researchProduct

Mineral Profile of Children’s Fast Food Menu Samples

2017

Abstract Children’s fast food menus, including hamburgers served with french fries, dessert, and a soft drink, were analyzed to obtain the mineral profile of trace elements. The developed analytical methodology involved sample digestion under pressure inside a microwave oven with a mixture of HNO3 and H2O2 and inductively coupled plasma-optical emission spectrometry. The method was validated by carrying out the analysis of certified reference materials (NIST 1570a spinach leaves, NCS ZC73016 chicken, and NIST 1568a rice flour) and using recovery experiments. Repeatability was verified by analyzing replicate samples. Twenty-six elements were studied, 12 of which—aluminum, barium, calcium, co…

0301 basic medicineAdolescentMicrowave ovenchemistry.chemical_element01 natural sciencesAnalytical Chemistry03 medical and health sciencesLimit of DetectionHumansEnvironmental ChemistryFood scienceChildMicrowavesPharmacologyMineralsStrontium030109 nutrition & dieteticsChemistryMagnesiumFrench friesSpectrum Analysis010401 analytical chemistryBariumHydrogen PeroxideRepeatabilityFood AnalysisTrace Elements0104 chemical sciencesCertified reference materialsMetalsChild PreschoolCalibrationFast FoodsAgronomy and Crop ScienceFood AnalysisFood ScienceJournal of AOAC INTERNATIONAL
researchProduct