Search results for "repeatability"
showing 10 items of 214 documents
In-Vivo Estimation and Repeatability of Force-Length Relationship and Stiffness of the Human Achilles Tendon using Phase Contrast MRI
2008
Purpose To devise a method using velocity encoded phase contrast MRI and MR-compatible dynamometry, for in vivo estimation of elastic properties of the human Achilles tendon and to assess within-session and day-to-day repeatability of this technique. Materials and Methods Achilles tendon force and calcaneus-movement-adjusted displacement were measured during a submaximal isometric plantarflexion in 4 healthy subjects, four repeated trials each. The measured force-length (F-L) relationship was least-squares fitted to a cubic polynomial. Typical error was calculated for tendon displacement at multiple force levels, stiffness from the “linear region,” and transition point from the displacement…
Measurement of EMG activity with textile electrodes embedded into clothing.
2007
Novel textile electrodes that can be embedded into sports clothing to measure averaged rectified electromyography (EMG) have been developed for easy use in field tests and in clinical settings. The purpose of this study was to evaluate the validity, reliability and feasibility of this new product to measure averaged rectified EMG. The validity was tested by comparing the signals from bipolar textile electrodes (42 cm(2)) and traditional bipolar surface electrodes (1.32 cm(2)) during bilateral isometric knee extension exercise with two electrode locations (A: both electrodes located in the same place, B: traditional electrodes placed on the individual muscles according to SENIAM, n=10 person…
Reliability of measuring the fat content of the lumbar vertebral marrow and paraspinal muscles using MRI mDIXON-quant sequence
2018
PURPOSE We aimed to assess the reliability of measuring the fat content of the lumbar vertebral marrow and the paraspinal muscles using magnetic resonance imaging (MRI) mDIXON-Quant sequence. METHODS Thirty-one healthy volunteers were included. All participants underwent liver mDIXON-Quant imaging on a 3.0 T Philips MRI scanner by observer A. Within two weeks, observer B repeated the scan. After the examination, each observer independently measured the fat content of the third lumbar vertebra (L3), and the psoas (PS), erector spinae (ES), and multifidus (MF) muscles on central L3 axial images. After two weeks, each observer repeated the same measurements. They were blinded to their previous…
Habituation and short-term repeatability of thermal testing in healthy human subjects and patients with chronic non-neuropathic pain
2008
We investigated habituation effects during thermal quantitative sensory testing (tQST) using 8 repetitive measurements for thermal detection and pain thresholds. The same measurements were repeated two days later. 39 healthy subjects and 36 patients with chronic non-neuropathic pain syndromes (migraine, tension-type headache, non-radicular back pain) were enrolled. The pain intensity was assessed using an 11-point (0-10) numerical rating scale. Measurements correlated significantly over the two days in both groups (r=0.41...0.62). Warm detection (WDT) and heat pain threshold (HPT) revealed no significant differences over these days. Cold detection (CDT) and pain thresholds (CPT) showed sign…
Feasibility and reproducibility of electroencephalography-based corticokinematic coherence
2020
Corticokinematic coherence (CKC) is the phase coupling between limb kinematics and cortical neurophysiological signals, reflecting cortical processing of proprioceptive afference, and it is reproducible when estimated with magnetoencephalography (MEG). However, feasibility and reproducibility of CKC based on electroencephalography (EEG) is still unclear and is the primary object of the present report. Thirteen healthy right-handed volunteers (seven females, 21.7 ± 4.3 yr) participated in two combined MEG/EEG sessions 12.6 ± 1.3 mo apart. Participants' dominant and nondominant index finger was continuously moved at 3 Hz for 4 min separately using a pneumatic-movement actuator. Coherence was …
Understanding the role of saliva in aroma release from wine by using static and dynamic headspace conditions.
2014
The aim of this work was to determine the role of saliva in wine aroma release by using static and dynamic headspace conditions. In the latter conditions, two different sampling points (t = 0 and t = 10 min) corresponding with oral (25.5 °C) and postoral phases (36 °C) were monitored. Both methodologies were applied to reconstituted dearomatized white and red wines with different nonvolatile wine matrix compositions and a synthetic wine (without matrix effect). All of the wines had the same ethanol concentration and were spiked with a mixture of 45 aroma compounds covering a wide range of physicochemical characteristics at typical wine concentrations. Two types of saliva (human and artifici…
Objective analysis of contact lens fit.
2015
Purpose: To assess the validity and repeatability of objective compared to subjective contact lens fit analysis. Methods: Thirty-five subjects (aged 22.0. ±. 3.0 years) wore two different soft contact lens designs. Four lens fit variables: centration, horizontal lag, post-blink movement in up-gaze and push-up recovery speed were assessed subjectively (four observers) and objectively from slit-lamp biomicroscopy captured images and video. The analysis was repeated a week later. Results: The average of the four experienced observers was compared to objective measures, but centration, movement on blink, lag and push-up recovery speed all varied significantly between them (p 0.05). The 95% conf…
Reproducibility of isometric strength: measurement of neck muscles
1999
Abstract Objective. To evaluate the repeatability of an advanced method of measuring the strength of functionally different groups of neck muscles using an isometric apparatus. Design. A repeated measures design was used within and between sessions. Background. Chronic neck pain has been associated with poor isometric neck strength. In rehabilitation, strength measurements may thus help to evaluate the basic condition and show whether or not treatments and exercises have been beneficial for improving strength. Previous tests have concentrated on testing strength while trying to bend forwards and backwards, but no biomechanics device, able to test rotator muscles, has been presented. Method.…
Reliability of different models to assess heart rate recovery after submaximal bicycle exercise.
2011
Abstract Objectives : Different models to assess HR recovery have been developed but knowledge of their reliability is poor at different submaximal exercise intensities and recovery durations. Our aim was to determine the reliability of HR recovery after a test on a cycle ergometer. Design : Twenty-one healthy individuals performed a submaximal exercise at 65% and 80% HR max followed by passive recovery. The exercise was repeated (retest) within 2 weeks to assess reliability. Method : HR recovery was assessed by 8 models, based on monoexponential kinetics or absolute recovery (recovered HR at fix time points). Intraclass correlation coefficient (ICC) and standard error of measurement (SEM, …
Experimental and methodological factors affecting test-retest reliability of amygdala BOLD responses.
2018
Previous studies reported poor to fair test-retest reliability of amygdala BOLD responses to emotional stimuli. However, these findings are very heterogeneous across and within studies. The present study sought to systematically examine experimental and methodological factors that contribute to this heterogeneity. Forty-six young subjects were scanned twice with a mean test-retest interval of 7 weeks. We compared amygdala reliability across three tasks: A face-matching task, passive viewing of emotional faces, and passive viewing of emotional scenes. We also explored whether extraction of physiological noise can affect the stability of amygdala responses. We assessed test-retest reliability…