Search results for "repeatability"

showing 10 items of 214 documents

On the repeatability of the EMI for the monitoring of bonded joints

2015

We study the feasibility and the repeatability of the electromechanical impedance (EMI) method for the health monitoring of lightweight bonded joints. The EMI technique exploits the coupling between the displacement field and the potential field of a piezoelectric material, by attaching or embedding a piezoelectric transducer to the structure to be monitored. The sensor is excited by an external voltage and the electrical admittance which is the ratio between the electric current and the applied voltage is measured as it depends on the mechanical coupling between the transducer and the host structure. Owing to this interaction, the admittance may represent a signature for the health of the …

Electromechanical impedance methodCouplingStructural health monitoringAdmittanceMaterials scienceElectronic Optical and Magnetic MaterialAcousticsLightweight structureBonded jointComputer Science Applications1707 Computer Vision and Pattern RecognitionRepeatabilityCondensed Matter PhysicsPiezoelectricityApplied MathematicTransducerEMIStructural health monitoringElectrical and Electronic EngineeringVoltageSPIE Proceedings
researchProduct

Multicommutation cold vapour atomic fluorescence determination of Hg in water.

2002

Abstract A multicommutation-based method has been developed for the on-line direct atomic fluorescence spectrometric (AFS) determination of Hg in waters without any previous sample treatment. The performance of the proposed procedure has been compared with that of a conventional AFS system based on continuous mode measurements. In short, the use of multicommutation, together with a reduction of the size of the liquid–gas phase separator, provides an increase of the laboratory productivity by improving the sample throughput by a factor of 3.6 and strongly reduces the sample consumed by a factor of 6 and reagent consumed by a factor of 8.4. The waste generation is reduced by a factor of 2.4 a…

MERCUREDetection limitAtomic fluorescencechemistryDirect methodReagentAnalytical chemistrychemistry.chemical_elementSeparator (oil production)RepeatabilityAnalytical ChemistryMercury (element)Talanta
researchProduct

Use of the modified quick easy cheap effective rugged and safe sample preparation approach for the simultaneous analysis of type A- and B-trichothece…

2010

A suitable extraction and purification method for the simultaneous liquid chromatography-mass spectrometry (LC-MS) determination of five mycotoxins, three type A, diacetoxyscirpenol (DAS), T-2 toxin (T-2) and HT-2 toxin (HT-2), and two type B-trichothecenes, deoxynivalenol (DON) and nivalenol (NIV), has been optimised using a modified "Quick Easy Cheap Effective Rugged and Safe" (QuEChERS) method. Different solvents were studied in the extraction procedure to obtain better recoveries, which ranged from 86 to 108%, using a 85/15 (v/v) mixture of methanol/acetonitrile. The values obtained for recovery, repeatability and reproducibility of the optimized method are in agreement with Commission …

AcetonitrilesChromatographyChemistryMethanolFlourOrganic ChemistryExtraction (chemistry)Wheat flourAnalytic Sample Preparation MethodsGeneral MedicineRepeatabilityQuechersBiochemistryMass SpectrometryDiacetoxyscirpenolAnalytical Chemistrychemistry.chemical_compoundVomitoxinLiquid chromatography–mass spectrometrySolventsSample preparationTrichothecenesTriticumChromatography LiquidJournal of Chromatography A
researchProduct

Comparison of direct mass spectrometry methods for the on-line analysis of volatile compounds in foods

2013

For the on-line monitoring of flavour compound release, atmospheric pressure chemical ionization (APCI) and proton transfer reaction (PTR) combined to mass spectrometry (MS) are the most often used ionization technologies. APCI-MS was questioned for the quantification of volatiles in complex mixtures, but direct comparisons of APCI and PTR techniques applied on the same samples remain scarce. The aim of this work was to compare the potentialities of both techniques for the study of in vitro and in vivo flavour release. Aroma release from flavoured aqueous solutions (in vitro measurements in Teflon bags and glass vials) or flavoured candies (in vivo measurements on six panellists) was studie…

Detection limitChromatography010504 meteorology & atmospheric sciencesbiologyChemistry010401 analytical chemistryFlavourAnalytical chemistryAtmospheric-pressure chemical ionizationRepeatabilityMass spectrometrybiology.organism_classification01 natural sciences0104 chemical sciencesAdsorptionIonizationSpectroscopyAroma0105 earth and related environmental sciencesJournal of Mass Spectrometry
researchProduct

A simple method of bronchoprovocation using a valved holding chamber.

2004

This study was undertaken to ascertain whether the use of a valved holding chamber (VHC) during bronchial provocation testing might increase lung deposition and repeatability of the test relative to the tidal breathing method. The 2-min tidal breathing results were compared to five inhalations from a VHC device in patients using the Pari-provoII nebulizer (MMD = 2.1mkm). Lung and mouth deposition, losses though the exhaled air and losses before aerosol delivery to the patient's mouth were measured in patients using a radiolabeled 99Tc-DTPA solution and gamma camera. The study revealed that lung deposition was 67% with the VHC method, and losses with exhaled air were 29% of the inhaled amoun…

Pulmonary and Respiratory Medicinemedicine.medical_specialtyBronchial Provocation TestsTidal VolumeMedicineHumansPharmacology (medical)In patientRadionuclide ImagingLungAerosolsLungbusiness.industryNebulizers and VaporizersRepeatabilityrespiratory systemHOLDING CHAMBERrespiratory tract diseasesSurgeryAerosolNebulizermedicine.anatomical_structureBronchial provocationTechnetium Tc 99m PentetateRadiopharmaceuticalsbusinessNuclear medicineDeposition (chemistry)Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine
researchProduct

Calibration of LA-ICP-MS via standard addition using dried picoliter droplets

2020

A novel microanalytical calibration approach for quantitative spatially resolved analysis of thin layered materials with laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) is presented. This method relies on standard addition via the generation of dried pL-droplet residues. Therefore, a drop on demand dosing device based on a modified commercial ink cartridge and a dosing interface, both accessible via a self-constructed microcontroller, were developed. This dosing device enables the precise deposition of pL-droplets onto solid samples for the generation of residues with dimensions in the low μm-range. The LA-ICP-MS analysis of such residues allows calibration over at l…

Detection limitMaterials scienceThin sectionSample (material)010401 analytical chemistryAnalytical chemistry02 engineering and technologyRepeatability021001 nanoscience & nanotechnologyMass spectrometryLaser01 natural sciences0104 chemical sciencesAnalytical Chemistrylaw.inventionCartridgelawStandard addition0210 nano-technologySpectroscopyJournal of Analytical Atomic Spectrometry
researchProduct

Metrological Properties of the Test Setup for Determination Shielding Effectiveness of the Industrial Cable Connectors

2017

Abstract The paper presents results related to assessment of the repeatability and reproducibility of the measurement test setup for determination the relative value of the shielding effectiveness coefficient of the industrial connectors. The construction of the proposed test setup, the measurement method and the procedure for the analysis of measurement results were described. To determine the value of the repeatability and reproducibility coefficient, the two–way analysis of variance was used, which additionally allows for an assessment of the influence of individual sources of variance. The measurements and their analysis were conducted for several frequencies in the range up to 1 GHz. A…

010302 applied physicsTest setupEngineeringReproducibilitybusiness.industry020208 electrical & electronic engineeringMechanical engineering02 engineering and technologyRepeatabilityVariance (accounting)01 natural sciencesReliability engineeringMetrology0103 physical sciencesElectromagnetic shielding0202 electrical engineering electronic engineering information engineeringRange (statistics)Measurement uncertaintybusinessInternational Journal of Electronics and Telecommunications
researchProduct

In-Vivo Estimation and Repeatability of Force-Length Relationship and Stiffness of the Human Achilles Tendon using Phase Contrast MRI

2008

Purpose To devise a method using velocity encoded phase contrast MRI and MR-compatible dynamometry, for in vivo estimation of elastic properties of the human Achilles tendon and to assess within-session and day-to-day repeatability of this technique. Materials and Methods Achilles tendon force and calcaneus-movement-adjusted displacement were measured during a submaximal isometric plantarflexion in 4 healthy subjects, four repeated trials each. The measured force-length (F-L) relationship was least-squares fitted to a cubic polynomial. Typical error was calculated for tendon displacement at multiple force levels, stiffness from the “linear region,” and transition point from the displacement…

AdultMaleMaterials scienceIsometric exerciseAchilles TendonArticleTransition pointmedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingDisplacement (orthopedic surgery)Least-Squares AnalysisAchilles tendonStiffnessReproducibility of ResultsAnatomyRepeatabilitymusculoskeletal systemMagnetic Resonance ImagingTendonmedicine.anatomical_structureCalcaneusStress Mechanicalmedicine.symptomBiomedical engineering
researchProduct

Assessing Repeatability and Reproducibility of Anterior Active Rhinomanometry (AAR) in Children

2020

AbstractBackgroundRepeatability and reproducibility are essential for clinicians for several purposes. Although discouraged, use of the Coefficient of Variation (CV) for assessing repeatability and reproducibility, rather than the Intraclass Correlation Coefficient (ICC), is still widespread. The aim of the present study was to highlight how using inappropriate indices may lead to misleading results, and this is done by simulation study and using real data on Anterior Active Rhinomanometry (AAR) in both healthy children and ones with rhinitis.MethodsA simulation study was carried out to highlight how using inappropriate indices could be misleading. Then a comparison was made between CV and …

MaleEpidemiologyIntraclass correlationCoefficient of variationHealth InformaticsRhinitis.03 medical and health sciences0302 clinical medicineMedicineHumans030212 general & internal medicineRepeatabilityChildChildren030304 developmental biologyRhinitisAnterior Active RhinomanometryNasal resistancelcsh:R5-9200303 health sciencesReproducibilityIntraclass Correlation Coefficientmedicine.diagnostic_testbusiness.industryReproducibility of ResultsGold standard (test)RepeatabilityRhinomanometryClinical PracticeCoefficient of Variationanterior active rhinomanometry; children; coefficient of variation; intraclass correlation coefficient; repeatability; rhinitisFemaleRhinomanometrylcsh:Medicine (General)businessNuclear medicineResearch Article
researchProduct

An effective negative pressure cavitation-microwave assisted extraction for determination of phenolic compounds in P. calliantha H. Andr.

2013

A novel negative pressure and microwave assisted extraction technique (NMAE) was first proposed and applied for extraction of phenolic compounds from pyrola. [C₄MIM]BF₄ aqueous solution was selected as extraction solvent. Optimal extraction conditions were microwave power 700 W, negative pressure -0.07 MPa, temperature 40 °C, liquid-solid ratio 20 : 1, ionic liquid (IL) concentration 0.5 M, extraction time 15 min. The predominance of NMAE was investigated by comparing with microwave-assisted extraction (MAE) and negative pressure cavitation extraction (NPCE) using a first-order kinetics equation. The C∞ values of the target compounds by NMAE were from 0.406 to 5.977 mg g⁻¹ higher than these…

ReproducibilityAqueous solutionChromatographyPlant ExtractsLiquid-Liquid ExtractionExtraction (chemistry)Analytical chemistryRepeatabilityBiochemistryAnalytical ChemistrySolventMatrix (chemical analysis)chemistry.chemical_compoundPhenolschemistryIonic liquidPressureElectrochemistryEnvironmental ChemistrySample preparationMicrowavesPyrolaChromatography High Pressure LiquidSpectroscopyThe Analyst
researchProduct