Search results for "residue"
showing 10 items of 390 documents
Solid-Phase Microextraction Liquid Chromatography/Tandem Mass Spectrometry To Determine Postharvest Fungicides in Fruits
2003
A method to determine five postharvest fungicides (dichloran, flutriafol, o-phenylphenol, prochloraz, tolclofos methyl) in fruits (cherries, lemons, oranges, peaches) has been developed using solid-phase microextraction (SPME) coupled to liquid chromatography (LC) with photodiode array (DAD), mass spectrometry (MS), or tandem mass spectrometry (MS/MS) with ion trap detection. Extraction involved sample homogenization with an acetone/water solution (5:1), filtration, and acetone evaporation prior to fiber extraction. The pesticides were isolated with a fused-silica fiber coated with 50-microm Carbowax/template resin. The effects of pH, ion strength, sample volume, and extraction time were in…
Determination of amitraz and its transformation products in pears by ethyl acetate extraction and liquid chromatography-tandem mass spectrometry.
2008
A method has been developed for identification and quantification of the acaricide amitraz and its transformation products, 2,4-dimethylaniline (DMA), 2,4-dimethylformamidine (DMF) and N-2,4-dimethylphenyl-N-methylformamidine (DMPF) in pears. The analytes were extracted using ethyl acetate and anhydrous sodium sulphate. Analysis was performed by liquid chromatography-electrospray tandem mass spectrometry (LC-ESI-MS/MS) in the positive ion mode using a triple quadrupole (QqQ) instrument. Two precursor-product ion transitions were monitored for each compound in the selected reaction monitoring (SRM) mode. The method was validated with pears taken from the orchard before the amitraz treatment …
Environmental and food applications of LC-tandem mass spectrometry in pesticide-residue analysis: An overview
2003
An overview is given on pesticide-residue determination in environmental and food samples by liquid chromatography/mass spectrometry/mass spectrometry (LC/MS/MS). Pesticides comprise a large number of substances that belong to many completely different chemical groups, the only common characteristic is that they are effective against pests. They still constitute a challenge in MS because there is no collective pathway for fragmentation. A brief introduction to the theory of tandem MS permits a discussion of which parameters influence the ionization efficiency when the ions are subjected to different actions. Emphasis is placed on the different tandem MS instruments: triple and ion-trap quad…
Rapid and sensitive ultra-high-pressure liquid chromatography-quadrupole time-of-flight mass spectrometry for the quantification of amitraz and ident…
2008
Liquid chromatography under high pressure in combination with quadrupole time-of-flight mass spectrometry (QqTOF-MS and MS/MS) has been used to detect amitraz degradation products in pears, to characterize their structures, and to evaluate their occurrences in samples of different origins. Using the proposed approach, the parent pesticide and four degradation products were identified. To this end, pear samples were extracted with ethyl acetate and anhydrous sodium sulphate. Amitraz was found to be rapidly decomposed into four related compounds, of which N-(2,4-dimethylphenyl)formamidine (DMPF) was the most abundant and persistent. N,N'-bisdimethylphenylformamidine (BDMPF), 2,4-dimethylforma…
Development of monoclonal antibody-based competitive immunoassays for the detection of picoxystrobin in cereal and oilseed flours
2012
Picoxystrobin is a new generation fungicide primarily developed to be used in cereal crops. In the present study a novel collection of specific monoclonal antibodies has been produced using different immunizing haptens based on a carboxy-functionalized identical spacer arm attached to alternative positions of the target pesticide molecule. Two competitive enzyme-linked immunosorbent assays have been developed employing hapten heterology, one using the antibody-coated direct format and the other in the conjugate-coated indirect format. Both immunoassays have been characterized in terms of selectivity, solvent tolerance, and buffer conditions, affording similar limits of detection at or below…
Determination of pesticides in soil samples by solid phase extraction disks
1993
A systematic study comparing the methodology and analytical results obtained in an investigation of seven pesticide residues (Molinate, Atrazine, Carbofuran, Pirimicarb, Prometryn, Malathion and Tetrachlorvinphos) in soil samples is reported. Solid-phase extraction (SPE) using glass columns and 47 mm disks of octyl and octadecyl-bonded silica was used in the pesticide analysis. The best extraction efficiency and clearest extracts are obtained with C8 disks. The analyses were carried out by capillary gas chromatography with nitrogen and phosphorus detection. Recovery experiments were performed at ppb levels in spiked soil samples. The average recoveries of the compounds were 53–77%. Detectio…
Matrix solid-phase dispersion extraction procedure for multiresidue pesticide analysis in oranges.
1996
A multiresidue extraction method based on matrix solid-phase dispersion (MSPD) is optimized for the extraction and gas chromatographic screening of eighteen insecticides (aldrin, carbophenothion, captafol, chlorpyriphos, chlorfenvinphos, diazinon, dicofol, alpha-endosulfan, beta-endosulfan, ethion, fenitrothion, folpet, methidathion, malathion, methyl-azinphos, methyl-parathion, phosmet, and tetradifon) from oranges. After optimization of different parameters, such as type of solid phase used and the amount of solid phase or eluent, recoveries ranged from 67 to 102% with relative standard deviations ranging from 2 to 10%. The limits of detection, calculated as 3 times the baseline noise ran…
Pressurised liquid extraction and capillary electrophoresis–mass spectrometry for the analysis of pesticide residues in fruits from Valencian markets…
2010
Abstract A procedure based in capillary electrophoresis–mass spectrometry (CE–MS) for the analysis of seven pesticides (flutolanil, simazine, haloxyfop, acifluorfen, dinoseb, picloram, and ioxynil) in four Mediterranean summer fruits with high water content (peaches, melon, watermelon, and apricot) is developed. Several conditions were studied for the optimisation of both, the separation and the electrospray (ESI) connection. The best results were obtained using 35 mM ammonium formiate (pH 9.7) as separation buffer, 20 °C as capillary temperature and 23 kV as applied voltage in an uncoated fused-silica capillary with 50 cm total length, 25 cm thermostated length, 25 cm at room temperature l…
Determination of benzoylurea insecticides in food by pressurized liquid extraction and LC-MS
2010
A method based on pressurized liquid extraction and LC-MS/MS has been developed for determining nine benzoylureas (BUs) in fruit, vegetable, cereals, and animal products. Samples (5 g) were homogenized with diatomaceous earth and extracted in a 22 mL cell with 22 mL of ethyl acetate at 80 degrees C and 1500 psi. After solvent concentration and exchange to methanol, BUs were analyzed by LC-MS/MS using an IT mass analyzer, which achieved several transitions of precursor ions that increase selectivity providing identification. LOQs were between 0.002 and 0.01 mg/kg, which are equal or lower than maximum residue limits established by the Codex Alimentarius. Excellent linearity was achieved over…
Capillary zone electrophoresis for the determination of thiabendazole, prochloraz and procymidone in grapes
2001
Capillary zone electrophoresis with UV detection was applied to the simultaneous determination of thiabendazole, prochloraz and procymidone in grapes. Electrolyte conditions such as pH, composition and concentration of the buffer, addition of organic solvent and working voltage were checked to obtain a high-performance separation of the three fungicides (by measurement of separation efficiency and resolution). The most critical parameter was the pH of the running buffer. The best separation was achieved in 4 mM phosphate solution at pH 3.5. The repeatability of the migration times, expressed as RSD, was <0.44%. The three peaks were completely resolved with a separation efficiency up to 100 …