Search results for "resin"
showing 10 items of 385 documents
Effect of blastfurnace slag addition to Portland cement for cationic exchange resins encapsulation
2013
In the nuclear industry, cement-based materials are extensively used to encapsulate spent ion exchange resins (IERs) before their final disposal in a repository. It is well known that the cement has to be carefully selected to prevent any deleterious expansion of the solidified waste form, but the reasons for this possible expansion are not clearly established. This work aims at filling the gap. The swelling pressure of IERs is first investigated as a function of ions exchange and ionic strength. It is shown that pressures of a few tenths of MPa can be produced by decreases in the ionic strength of the bulk solution, or by ion exchanges (2Na + instead of Ca 2+ , Na + instead of K + ). Then,…
Influence of thickness and translucency of lithium disilicate ceramic on degree of conversion of resinous materials
2020
Background In this study was assessed the degree of conversion (DC) of amine-free resin cements light cured through lithium disilicate-reinforced ceramics at different thicknesses and translucency. Material and Methods Specimens were divided into 21 groups (n = 5) according to luting agent used: Variolink Esthetic LC (Light shade), RelyX Ultimate (A1 shade), and Filtek Z350 XT Flow (A1 shade); the ceramic translucency: low (LT) and high (HT); and the ceramic thickness: no ceramic (control), 0.5 mm, 1 mm, and 2 mm. A Teflon mold with (5 x 5 x 0.5 mm) was used to standardize the cement and over it the ceramic block from each group was placed. Set was cured using a polywave LED light (1200 mW/…
Influence of resin cement shade on the color and translucency of zirconia crowns
2020
Background Zirconia crowns are highly attractive for clinicians, although have poor translucency when used as single restorations, in addition to unknown effect of resin cement shade on final cemented crown shade. This study aimed to assess effect of resin cement opacity on color replication potential of different zirconia frameworks with target tooth color, in addition to different zirconia crowns translucency evaluation. Material and methods Twenty-four zirconia crown restorations were fabricated to restore single central maxillary incisor for 8 patients, divided into 3 groups according to color and type of zirconia used (white Zr core, colored Zr core and monolithic HT Zrcowns). Each gro…
Bond strength of selected composite resin-cements to zirconium-oxide ceramic
2012
Objectives: The aim of this study was to evaluate bond strengths of zirconium-oxide (zirconia) ceramic and a selection of different composite resin cements. Study Design: 130 Lava TM cylinders were fabricated. The cylinders were sandblasted with 80 μm aluminium oxide or silica coated with CoJet Sand. Silane, and bonding agent and/or Clearfil Ceramic Primer were applied. One hundred thirty composite cement cylinders, comprising two dual-polymerizing (Variolink II and Panavia F) and two autopolymerizing (Rely X and Multilink) resins were bonded to the ceramic samples. A shear test was conducted, followed by an optical microscopy study to identify the location and type of failure, an elec…
In vitro experimental study of bonding between aluminium oxide ceramics and resin cements
2010
To evaluate bond strengths of different resin cements to two aluminum oxide-based ceramics. Methods: One hundred ten ceramic cylinders were produced and given four different surface treatments. Resin cement cylinders were then bonded to the ceramic cylinders using different resin cements and the bond strength was determined by shear testing to the breaking point. We were thus able to obtain results for the different combinations of porcelain, surface treatments and cements. All data was analyzed using the Kruskal-Wallis test for more than two independent samples and the Bonferroni correction applied (a=0.01). An optical microscopy study was carried out to analyze the type of failure, and an…
Bond strength of lithium disilicate after cleaning methods of the remaining hydrofluoric acid
2020
Background Complex implant treatments have steadily increased within implant prosthodontics. Based on the lower implant mobility, implant impressions need high accuracy in the model transfer to receive a high passive fit within the final prosthodontic restoration. To analyze the accurate 3-dimensional (3D) inter-implant-positions, a reference point is indispensable. However, there is no reference in the patients mouth, so the aim of the present study was to develop a new method based on a custom-made-measuring-aid (CMA) to assess the inter implant dimensions (InID) in patients. Material and Methods Initially an implant master model (IMM/patient equivalent) was digitized by computed tomograp…
Resistance to bond degradation between dual-cure resin cements and pre-treated sintered CAD-CAM dental ceramics
2012
Objective: To evaluate the bond stability of resin cements when luted to glass-reinforced alumina and zirconia CAD/CAM dental ceramics. Study design: Eighteen glass-infiltrated alumina and eighteen densely sintered zirconia blocks were randomly conditioned as follows: Group 1: No treatment; Group 2: Sandblasting (125 µm Al2O3-particles); and Group 3: Silica-coating (50 µm silica-modified Al2O3-particles). Composite samples were randomly bonded to the pre-treated ceramic surfaces using different resin cements: Subgroup 1: Clearfil Esthetic Cement (CEC); Subgroup 2: RelyX Unicem (RXU); and Subgroup 3: Calibra (CAL). After 24 h, bonded specimens were cut into 1 ± 0.1 mm2 sticks. One-half of th…
Mechanical performance of experimental acrylic resins modified by nanoparticles after chemical and mechanical degradation.
2020
Background Different materials have been incorporated into the polymethylmethacrylate matrix to improve its performance. The aim of this study was to evaluate the degree of conversion (DC), the flexural strength (FS), the elasticity modulus (EM), and the effect of exposure to food-simulating liquids prior to brushing simulation on the gloss loss (GL) of experimental acrylic resins modified by nanoparticles. Material and methods Three different types of nanoparticles; silicon oxide (SiO2), cerium oxide (CeO2) and titanium oxide (TiO2) were added to a poly (methylmethacrylate) matrix, in proportions of 0.5wt%, 1wt% and 3wt% each, forming nine experimental groups. The acrylic resin was also te…
Extraction of uranyl ions from aqueous solutions using silica-gel-bound macrocycles for alpha contaminated waste water treatment
2004
Abstract The efficiency for the extraction of U(VI) of new modified silica gels, namely N-tripropionate (or N-triacetate)-substituted tetraazamacrocycles-bound silica gels, has been studied. The effect of the nature of the ligand, the pH and the temperature was studied both in batch experiments as well as in continuous extraction. These silica gels are good candidates for the extraction of U(VI) when compared to a commercially available acid-type chelating resin. The breakthrough and regeneration tests showed that the total removal of U(VI) from a contaminated solution can be achieved by using a column packed with such tetraazamacrocycles-bound silica gels. Finally, the use of a modified si…
Micro-analytical identification of the components of varnishes from South Italian historical musical instruments by PLM, ESEM-EDX, microFTIR, GC-MS, …
2014
Abstract A multi-analytical investigation was carried out to study varnish micro-samples from historical stringed musical instruments from the collection of the “Vincenzo Bellini” Conservatory in Palermo (Italy). This paper reports on the results of the application of five micro-destructive techniques: optical microscopy analysis of cross-sections, micro-Fourier transform infrared spectroscopy, gas chromatography coupled with mass spectrometry, pyrolysis gas chromatography coupled with mass spectrometry with thermochemolysis, and environmental scanning electron microscopy with X-ray microanalysis. The study provides microchemical information about the composition of the varnishes of the ins…