Search results for "resolution."
showing 10 items of 1825 documents
To transmit genes without becoming mother: An evolutionary conflict behind denial of pregnancy
2016
Aim: The etiology of pregnancy denial remains poorly understood. Neither necessary nor sufficient conditions can be synthesized from the risk factors identified from psychological analyses. In accordance with clinical observations, we aim to explain denial of pregnancy from an evolutionary conflict perspective. Methods: Authors investigate evolutionary biology aspects and emphasize on the transition from solitary animal species to social species. The possibility of conflicts between primitive species-perpetuation forces and subjective social-identity forces are explored. Results: As members of a social species, human beings have a dual, contradictory character of independent organisms but i…
Denoising 3D Models with Attributes using Soft Thresholding
2004
International audience; Recent advances in scanning and acquisition technologies allow the construction of complex models from real world scenes. However, the data of those models are generally corrupted by measurement errors. This paper describes an efficient single pass algorithm for denoising irregular meshes of scanned 3D model surfaces. In this algorithm, the frequency content of the model is assessed by a multiresolution analysis that requires only 1-ring neighbourhood without any particular parameterization of the model faces. Denoising is achieved by applying the soft thresholding method to the detail coefficients given by the multiresolution analysis. Our method is suitable for irr…
Automated high-performance liquid chromatographic determination of amphetamine in biological fluids using column-switching and on-column derivatizati…
1999
A rapid and simple liquid-chromatographic method has been developed for on-line quantification of amphetamine in biological fluids. Untreated samples (20 μL) are injected directly into the chromatographic system and purified on a 20 mm×2.1 mm i.d. pre-column packed with 30 μm Hypersil C18 stationary phase. After clean-up the analyte is transferred to the analytical column (125 mm×4 mm i.d., 5 μm LiChrospher 100 RP18) for derivatization and separation using a mixture of acetonitrile and the derivatization reagent (o-phthaldialdehyde andN-acetyl-L-cysteine) as the mobile phase. The experimental conditions for on-line derivatization and resolution of the amphetamine have been optimized, and th…
Exploring hand-portable nano-liquid chromatography for in place water analysis: Determination of trimethylxanthines as a use case.
2020
Abstract Analytical performance and optimization of figures of merit of a portable nano liquid chromatograph (NanoLC) with UV detection at 255 nm have been established for in place analysis. Methylxanthines: caffeine, theophylline and theobromine were selected as target analytes. A fast lab method based on IT-SPME coupled on line with capillary liquid chromatograph (CapLC) with diode array detection (DAD) was employed for comparative studies. IT-SPME and solid phase extraction were coupled off-line to NanoLC for improving instrumental parameters, mainly detection capacity and selectivity. IT-SPME or SPE/portable NanoLC based methods were superior in terms of chromatographic resolution and o…
Sensitive determination of parabens in human urine and serum using methacrylate monoliths and reversed-phase capillary liquid chromatography-mass spe…
2014
A method for the determination of parabens in human urine and serum by capillary liquid chromatography (cLC) with UV-Vis and mass spectrometry (MS) detection using methacrylate ester-based monolithic columns has been developed. The influence of composition of polymerization mixture was studied. The optimum monolith was obtained with butyl methacrylate monomer at 60/40% (wt/wt) butyl methacrylate/ethylene dimethacrylate ratio and 50wt% porogens (composed of 36wt% of 1,4-butanediol, 54wt% 1-propanol and 10wt% water). Baseline resolution of analytes was achieved through a mobile phase of acetonitrile/water in gradient elution mode. Additionally, dispersive liquid-liquid microextraction (DLLME)…
Fourier transform infrared determination of Fluometuron in pesticide formulations
2003
Abstract A single method has been developed for Fourier transform infrared (FTIR) determination of Fluometuron in pesticide formulations. Samples were ultrasonically shaken with CHCl3 for 5 min and the FTIR spectra of sample extracts and standards were obtained at a nominal resolution of 4 cm−1 from 4000 to 900 cm−1 accumulating 25 scans. Fluometuron determination is based on the measure of peak area from 1342 to 1321 cm−1 corrected using a baseline defined from 1352 to 1294 cm−1. This procedure provided a limit of detection of 6.5 μg g−1, a sensitivity of 0.852 a.u. g mg−1 for a pathlength of 0.11 mm, a relative standard deviation of 1.6% for three analysis of a sample containing 50.4% (w/…
In situ derivatization for double confirmation of 2C–C in oral fluids by ion mobility spectrometry
2017
Ion mobility spectrometry (IMS) is a powerful tool to carry out quick and sensitive detection of illicit activities and has been employed for the determination of the psychedelic drug 2,5-dimethoxy-4 chlorophenethylamine (2C–C) in oral fluid samples. Saliva samples were extracted with chloroform and analysed by IMS reaching a limit of detection (LOD) of 14 μg L−1. Nevertheless, IMS has a scarce resolution and selectivity of the method can be often compromised by the presence of potential interferents with similar molecular weights and drift times. Thus, a rapid and in situ derivatization with acetone, to form the corresponding imine, has been proposed in the present study to confirm the pre…
Identification of Leguminosae gums and evaluation of carob-guar mixtures by capillary zone electrophoresis of protein extracts.
2002
A procedure for the extraction and capillary zone electrophoresis (CZE) separation of proteins from carob, guar and tara gums in a background electrolyte (BGE) of pH 9 containing 0.1% polyvinyl alcohol is described. The CZE protein profiles exhibit characteristic peaks for each one of the Leguminosae gums, which can be used to construct models capable of identifying samples of carob, guar and tara gums, and predicting the guar content in binary carob-guar mixtures of different geographical origin and harvested in different years. The classification and prediction models are constructed by using linear discriminant analysis (LDA) and multiple linear regression (MLR), respectively. An excelle…
Novel approach for the determination of azithromycin in pharmaceutical formulations by Fourier transform infrared spectroscopy in film-through transm…
2013
Abstract This work reports the development of a new method for the determination of azithromycin in pharmaceutical formulations employing Fourier transform infrared (FTIR) technique. The measurements were performed using a novel approach based on a film-through transmission mode. Several variables that could influence the analytical performance of the method were evaluated (solvent, nominal resolution, number of scans, mode of measurement and spectral region selected for measurement). Acetonitrile was the best solvent for the determination of azithromycin, employing the absorption band of the C O group at 1729 cm− 1. The extraction of azithromycin from the formulations was made by mechanica…
Fourier transform infrared determination of imidacloprid in pesticide formulations
2004
A simple method has been developed for Fourier Transform Infrared (FTIR) determination of Imidacloprid in pesticide formulations. Samples were diluted with CHCl3 and the FTIR spectra of samples and standards were obtained at a nominal resolution of 4 cm-1 from 4000 to 900 cm-1 accumulating 25 scans. Imidacloprid determination was based on the measure of either peak area from 1577 to 1567 cm-1 or peak height at 1572 cm-1, both corrected using a horizontal baseline defined at 1900 cm-1. The limits of detection achieved, of the order of 9 µg g-1, were appropriate for the determination of Imidacloprid in commercially available formulations. FTIR results were statistically comparable to those fo…