Search results for "resolution"
showing 10 items of 1928 documents
ATR-FTIR spectroscopy as a quality control system for monitoring the storage of blood products
2021
Blood screening is a fundamental part of disease diagnosis and monitoring health. Attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy offers an innovative solution to streamlining the process, especially for multianalyte detection in aqueous samples. However, samples always undergo a storage phase before they are processed for testing and blood transfusion. In this study, we investigated the effect of standard storage procedures on the macromolecular composition of whole blood, and plasma collected in blood tubes for diagnostic purposes and initial screening of blood products. Periphery blood samples were collected from 10 volunteers and then stored for 14 days a…
Field-induced ferromagnetism due to magneto-striction in 1-D helical chains
2016
Two homochiral copper(II) helices, [Cu(μ1,3-N3)(L1)]n (1) and [Cu(μ1,3-NCO)(L2)]n (2), with end-to-end pseudohalide bridges, were synthesized using two N2O donor achiral Schiff bases via spontaneous chiral resolution. Field-induced ferromagnetic ordering due to magneto-striction in homochiral 1-D helix [Cu(μ1,3-N3)(L1)]n (1) is reported for the first time. At temperatures below 5.5 K, under a magnetic field of 1 T, orthogonality between the magnetic orbitals of copper centres increases significantly due to the contraction of lattice parameters, giving rise to long-range ferromagnetic ordering in the helical chain. The magneto-dielectric results are also indicative of the observed magneto-st…
Resolution Enhancement in Phase Microscopy: a Review
2018
Quantitative phase microscopy (QPM), a technique combining phase imaging and microscopy, enables visualization of the 3-D topography in reflective samples as well as the inner structure or refractive index distribution of transparent and translucent samples. However, as in conventional optical microscopy, QPM provides either a large field of view (FOV) or a high resolution but not both. Many approaches such as oblique illumination, structured illumination and speckle illumination have been proposed to improve the spatial resolution of phase microscopy by restricting other degrees of freedom (mostly time). Therefore, the space bandwidth product (SBP) of QPM becomes enlarged. This paper aims …
Modeling the chiral resolution ability of highly sulfated β-cyclodextrin for basic compounds in electrokinetic chromatography
2013
Abstract Despite the fact that extensive research in the field of enantioseparations by capillary electrophoresis has been carried out, it is difficult to predict whether a concrete chiral selector would be useful for the separation of a racemic compound. Hence, several experimental effort is necessary to test the abilities of individual chiral selectors, usually by trial and error procedures. Thus, the enantioseparation of a new racemate becomes a time- and money-consuming task. In this work, the ability of highly sulfated β-cyclodextrin (HS-β-CD) as chiral selector in electrokinetic chromatography (EKC) is modeled for the first time, using exclusively directly-available structural data of…
The rotational spectrum of trans-DCOOD: Lamb-dip measurements, THz spectroscopy and quantum-chemical calculations
2011
Abstract The rotational spectrum of the bi-deuterated isotopologue of trans-formic acid, trans-DCOOD, was recorded at sub-Doppler resolution in the millimeter- and sub-millimeter-wave region using the Lamb-dip technique. The hyperfine structure due to the deuterium nuclei could be resolved and accurate hyperfine constants were derived. The experimental determination of the deuterium quadrupole-coupling constants was supported by high-level quantum-chemical calculations at the coupled-cluster level using large atomic-orbital basis sets. The Lamb-dip measurements were also supplemented by THz Doppler-limited measurements in order to extend the predictive capability of the available spectrosco…
Hydrogen CARS thermometry in H2-N2 mixtures at high pressure and medium temperatures: influence of linewidths models
2000
International audience; In order to improve the accuracy of H2 CARS thermometry, H2 Q-branch CARS spectra have been recorded for various H2-N2 mixtures in a high-pressure cell at different pressures and temperatures (up to 40 bar and 875 K). Due to the low spectral resolution of broadband CARS experiments, the relevant spectral lineshape factor is the linewidth ratio G(Q(3))/G(Q(1)), since Q(1) and Q(3) are the most intense lines of the Q-branch spectrum in this temperature range. For the first time, the speed-inhomogeneous effects are accounted for in the simulation of the CARS profiles. The evaluated temperatures are in good agreement with reference values obtained by thermocouples. The s…
Magnetic octupole moment of Yb-173 using collinear laser spectroscopy
2021
The hyperfine constants of the $4{f}^{14}6s6p^{3}P_{2}^{o}$ state in neutral Yb have been measured using three different dipole transitions. This state was recently shown to have a comparatively large hyperfine magnetic octupole splitting, and thus a puzzlingly large magnetic octupole moment. The measurement is performed using collinear laser spectroscopy on a fast atomic beam, which provides a straightforward route to probing long-lived metastable atomic states with high resolution. From the combined analysis of all three lines we find no significant evidence for a nonzero octupole moment in $^{173}\mathrm{Yb}$.
Validation of daily global solar irradiation images from MSG over Spain
2013
Abstract Daily irradiation images over Spain – area that embraces a highly heterogeneous landscape, climatic conditions and relief – are calculated from the down-welling surface short-wave radiation flux (DSSF) product derived from the MSG SEVIRI images. Their analysis and validation is carried out using two different station networks along the year 2008. The first network covers the peninsular Spain and Balearic islands. A denser one, covering the Catalonian territory and including many stations located in rugged terrain, is found useful to assess the elevation correction to be applied to the images. The statistics from the validation using the first network shows a relative mean bias of a…
A VLBI study of the wind-wind collision region in the massive multiple HD 167971
2019
Context. Colliding winds in massive binaries are able to accelerate particles up to relativistic speeds as the result of the interaction between the winds of the different stellar components. HD 167971 exhibits this phenomenon which makes it a strong radio source. Aims. We aim at characterizing the morphology of the radio emission and its dependence on the orbital motion, traced independently by near-infrared (NIR) interferometry of both the spectroscopic binary and the tertiary component comprising HD 167971. Methods. We analyze 2006 and 2016 very long baseline interferometric data at C and X bands. We complement our analysis with a geometrical model of the wind-wind collision region and a…
Determination of macro, micro nutrient and trace element concentrations in Indian medicinal and vegetable leaves using instrumental neutron activatio…
1999
Abstract Leafy samples often used as medicine in the Indian Ayurvedic system and vegetables were analyzed for 20 elements (As, Ba, Br, Ca, Ce, Cr, Cs, Co, Eu, Fe, K, La, Na, Rb, Sb, Sc, Sm, Sr, Th, Zn) by employing Instrumental Neutron Activation Analysis (INAA). The samples were irradiated at the 100 kW TRIGA-MAINZ nuclear reactor and the induced activities were counted by gamma ray spectrometry using an efficiency calibrated high resolution High Purity Germanium (HPGe) detector. The concentration of the elements in the medicinal and vegetable leaves and their biological effects on human beings are discussed.