Search results for "resolution"
showing 10 items of 1928 documents
Q fever: a new ocular manifestation
2011
P Udaondo1,3, S Garcia-Delpech1,2, D Salom1,2, M Garcia-Pous1, M Diaz-Llopis1,21Department of Ophthalmology, Nuevo Hospital Universitario y Politecnico La Fe, Valencia, Spain; 2Faculty of Medicine, Universitat de València, Valencia, Spain; 3Universidad Cardenal Herrera CEU, Valencia, SpainAbstract: Q Fever is a zoonosis caused by Coxiella burnetii. Ocular manifestations are rare in this infection. We describe the case of a man complaining of an intense retro-orbital headache, fever, arthralgia, and bilateral loss of vision, who showed an anterior uveitis accompanied by exudative bilateral inferior retinal detachment and optic disk edema. At the beginning, a Vogt–Koyanag…
Drift Time Measurement in the ATLAS Liquid Argon Electromagnetic Calorimeter using Cosmic Muons
2010
The ionization signals in the liquid argon of the ATLAS electromagnetic calorimeter are studied in detail using cosmic muons. In particular, the drift time of the ionization electrons is measured and used to assess the intrinsic uniformity of the calorimeter gaps and estimate its impact on the constant term of the energy resolution. The drift times of electrons in the cells of the second layer of the calorimeter are uniform at the level of 1.3% in the barrel and 2.8% in the endcaps. This leads to an estimated contribution to the constant term of (0.29-0.04+0.05)% in the barrel and (0.54-0.04+0.06)% in the endcaps. The same data are used to measure the drift velocity of ionization electrons …
Multi frequency phase fluorimetry (MFPF) for oxygen partial pressure measurement: ex vivo validation by polarographic clark-type electrode.
2013
BACKGROUND: Measurement of partial pressure of oxygen (PO2) at high temporal resolution remains a technological challenge. This study introduces a novel PO2 sensing technology based on Multi-Frequency Phase Fluorimetry (MFPF). The aim was to validate MFPF against polarographic Clark-type electrode (CTE) PO2 measurements. METHODOLOGY/PRINCIPAL FINDINGS: MFPF technology was first investigated in N = 8 anaesthetised pigs at FIO2 of 0.21, 0.4, 0.6, 0.8 and 1.0. At each FIO2 level, blood samples were withdrawn and PO2 was measured in vitro with MFPF using two FOXY-AL300 probes immediately followed by CTE measurement. Secondly, MFPF-PO2 readings were compared to CTE in an artificial circulatory s…
Observational Approach and Perspective
1983
Well you did not cover more than half of my planned talk! (laughter). Let me comment on interferometric techniques, in particular speckle imaging which you mentioned. Doing speckle imaging with the largest telescopes now available will not give you better than the theoretical resolving power of the telescope. With a 4m telescope that is about 30 marc sec in the visible. That happens to be the radius of the supergiant Betelguese. So you are not going to achieve much with speckle imaging on these stars. One technique which has not been adequately exploited is that of lunar occultation which can give much better angular resolution than speckle, of the order of 2-3 marc sec. By using suitably c…
Clasificación de usos del suelo a partir de imágenes Sentinel-2
2017
[EN] Sentinel-2 (S2), a new ESA satellite for Earth observation, accounts with 13 bands which provide high-quality radiometric images with an excellent spatial resolution (10 and 20 m) ideal for classification purposes. In this paper, two objectives have been addressed: to determine the best classification method for S2, and to quantify its improve-ment with respect to the SPOT operational mission. To do so, four classifiers (LDA, RF, Decision Trees, K-NN) have been selected and applied to two different agricultural areas located in Valencia (Spain) and Buenos Aires (Argentina). All classifiers were tested using, on the one hand, all the S2 bands and, on the other hand, only selecting those…
The Indian-French Trishna Mission: Earth Observation in the Thermal Infrared with High Spatio-Temporal Resolution
2018
International audience; The monitoring of the water cycle at the Earth surface which tightly interacts with the climate change processes as well as a number of practical applications (agriculture, soil and water quality assessment, irrigation and water resource management, etc...) requires surface temperature measurements at local scale. Such is the goal of the Indian-French high spatio-temporal TRISHNA mission (Thermal infraRed Imaging Satellite for High-resolution Natural resource Assessment). The scientific objectives of the mission and research work conducted to consolidate the mission specifications are presented. Progress in modelling of surface fluxes is then discussed. The main spec…
Batch Methods for Resolution Enhancement of TIR Image Sequences
2015
Thermal infrared (TIR) time series are exploited by many methods based on Earth observation (EO), for such applications as agriculture, forest management, and meteorology. However, due to physical limitations, data acquired by a single sensor are often unsatisfactory in terms of spatial or temporal resolution. This issue can be tackled by using remotely sensed data acquired by multiple sensors with complementary features. When nonreal-time functioning or at least near real-time functioning is admitted, the measurements can be profitably fed to a sequential Bayesian algorithm, which allows to account for the correlation embedded in the successive acquisitions. In this work, we focus on appli…
First results from the PROBA/CHRIS hyperspectral/multiangular satellite system over land and water targets
2005
The Project for On-Board Autonomy (PROBA) platform developed by the European Space Agency was launched on October 22, 2001. The instrument payload includes the Compact High Resolution Imaging Spectrometer (CHRIS). The coupled system provides high spatial resolution hyperspectral/multi-angular data, which represents a new-generation source of information for Earth observation purposes. The first results obtained from the preprocessing (noise removal and geometric/atmospheric correction) of two different datasets, collected over agricultural crops and inland waters, are presented in this letter. In situ measurements are used to assess the quality of the data and to validate the processing alg…
On the demands on imaging spectrometry for the monitoring of global vegetation fluorescence from space
2013
Vegetation fluorescence when measured from space contributes only a tiny fraction of the signal coming on top of the reflected radiance by the Earth surface and the atmosphere. As a consequence, imaging spectrometers have to provide sufficient throughput and radiometric accuracy to enable accurate global monitoring of the daily to seasonal variations of the Earth's vegetation breath, which is particularly challenging if ground resolutions of a few hundred meters are targeted. Since fluorescence retrieval algorithms have to make corrections for atmospheric effects, it is necessary to provide sufficient spectral resolution, so that signal alterations due to the main parameters such as surface…
Surface soil humidity retrieval using remote sensing techniques: a triangle method validation
2010
Soil humidity plays a key-role in hydrological and agricultural processes. In the rainfall-runoff processes the knowledge of its spatial distribution is fundamental to accurately model these phenomena. Furthermore in agronomy and agricultural sciences, assessing the water content of the root zone is required in order to optimize the plant productivity and to improve the irrigation systems management. Despite the importance of this variable the in situ measurements techniques based on Time Domain Reflectometry (TDR) or on the standard thermo-gravimetric methods, are neither cost-effective nor representative of its spatial and temporal variability. Indirect estimations via Earth Observation (…