Search results for "reste"
showing 10 items of 211 documents
Sicilian DES Registry: prospective in-hospital and 9-month clinical and angiographic follow-up in selected high restenosis risk patients.
2008
OBJECTIVE: This is a multicentre, open label, prospective non-randomized registry, with 9-month angiographic follow-up, conducted to evaluate the safety and effectiveness of drug-eluting stents (DES) when used in high restenosis risk patients from the real world. METHODS: From June 2004 to February 2005, a total of 1622 consecutive patients were enrolled to the Sicilian DES Registry, according to specific inclusion criteria. Both paclitaxel-eluting and sirolimus-eluting stents were used. The analysis was performed on 1472 patients because 150 patients were excluded from the study. The primary endpoint was to evaluate the rate of major adverse cardiac events (MACE) within 9 months after DES …
Long-term clinical outcomes after drug-eluting stent implantation in unprotected left main coronary artery disease.
2009
Objective: To investigate long-term outcomes of unprotected left main coronary artery (ULMCA) disease treatment using drug-eluting stents (DES). Background: In several studies, DES implantation in ULMCA appeared safe and effective at mid-term; however, to date, there is limited long-term data. Methods: All consecutive patients undergoing sirolimus- or paclitaxel-eluting stent implantation in ULMCA disease at a single institution were evaluated. The primary endpoint was long-term major adverse cardiac events (MACE) defined as cardiac death, nonfatal myocardial infarction, or target lesion revascularization (TLR). Stent thrombosis (ST), according to Academic Research Consortium definitions, w…
Analysis of risk factors for restenosis after PTCA
1990
To identify risk factors for restenosis, we evaluated data in 473 patients with single-vessel percutaneous transluminal coronary angioplasty (PTCA) and control angiography after 6 months. Restenosis, defined as (1) loss greater than 50% of the initial gain, and (2) stenosis greater than 50% was found in 138 patients (29.2%). Univariate analysis revealed eight factors related to restenosis: (1) duration of symptoms less than 1 month (P = 0.005), (2) unstable angina (P = 0.004), (3) high-grade stenosis before PTCA (P = 0.014), (4) large residual stenosis after PTCA (P = 0.001), (5) insufficient improvement of stenosis (P = 0.042), (6) prolonged single inflation time (P = 0.017), (7) prolonged…
Influence of vessel dilatation on restenosis after successful percutaneous transluminal coronary angioplasty.
1996
The aim of this study was to evaluate the influence of vessel dilation on restenosis after successful percutaneous transluminal coronary angioplasty (PTCA) on the basis of quantitative angiographic analysis. To have the best comparison possible, we restrospectively studied a homogenous series of patients from the early 1980s treated according to a standardized PTCA procedure. The study group consisted of 86 patients with stable angina pectoris and single-vessel disease, all of whom underwent successful PTCA for a short concentric lesion in proximal vessel parts. The overall restenosis rate was 27%. Angiographically measured balloon size remained below specifications. The size of the inflate…
A novel 3-d reconstruction system for the assessment of bifurcation lesions treated by the mini-crush technique.
2010
Background: Conventional two-dimensional angiography lacks the ability to properly image the true bifurcation geometry, and its percutaneous coronary intervention-induced changes in the clinical setting. Methods and Results: A novel three-dimensional reconstruction system was investigated by retrospectively analyzing 39 lesions in 35 consecutive patients with coronary bifurcation disease treated with the mini-crush technique. At baseline, significant correlations were proved between two- and three-dimensional systems in terms of either reference vessel diameter (R 2 = 0.68 and 0.29 for main and side branches, respectively), minimum lumen diameter (R 2 = 0.73 and 0.36), stenosis diameter (R …
Cryoplasty versus angioplasty in the treatment of arterial restenosis in an experimental model of atherosclerosis in rabbits
2014
Abstract Cryoplasty may reduce the incidence of post-angioplasty restenosis in peripheral atherosclerotic arteries. Our study is looking to investigate the mid-term effects (4 weeks) of an FDA-approved cryoplasty catheter (PolarCath®, Boston Scientific) compared to a conventional angioplasty catheter using a hypercholesterolemic rabbit model of arterial restenosis based on diet plus vessel injury. Thirty-six normolipidemic, 3-month old male New Zealand White rabbits were used. Balloon angioplasty was performed on left external iliac arteries on day 1. Animals were fed with a hypercholesterolemic diet for 60 days. On day 120, three groups of animals were established: conventional PTA (percut…
Subclavian Stenosis/Occlusion in Patients with Subclavian Steal and Previous Bypass of Internal Mammary Interventricular Anterior Artery: Medical or …
2004
There are only a few published studies on the association between subclavian steal syndrome and ischemic heart disease. The objective of this report is to evaluate the efficacy of subclavian stenoocclusion treatment in patients with subclavian steal syndrome (SSS) and previous cor- onary bypass. Over the last 8 years we observed 207 patients who underwent left internal mammary artery–intraventricular artery (LIMA–IVA) bypass graft. Of these, 31 patients were affected by steno-occlusion of the homolateral subclavian artery. Ten patients (group 1) showed latent vertebral-SSS and were pharmacologically treated. Seven patients (group 2) had an intermittent vertebral-SSS; four patients were trea…
Combining Sirolimus-eluting Stents and External Irradiation in Cholesterol-fed Rabbits Increased Incomplete Stent Apposition and Decreased Re-endothe…
2009
Restenosis after the implantation of a drug-eluting stent or after vascular irradiation therapy shares similar physiopathological mechanisms. No experimental data are currently available on vascular wall behavior after external irradiation on arteries stented with sirolimus-eluting stents (SES). Ten New Zealand white rabbits received a 0.5% cholesterol-enriched chow for 1 month. Bilateral iliac artery stent implantation was then performed with an SES (Cypher; Cordis Corp). The animals were randomized into either an irradiated group (I, 2 Gy external x-ray irradiation, n = 5) or a control group (C, n = 5). The cholesterol-enriched chow was continued for 1 additional month after stent implant…
9-Month Clinical and Angiographic Outcomes of the COBRA Polyzene-F NanoCoated Coronary Stent System
2016
Abstract Objectives The aim of this study was to assess the safety and effectiveness of the COBRA Polyzene-F NanoCoated Coronary Stent System (CeloNova Biosciences, San Antonio, Texas) for the treatment of de novo coronary artery lesions. Background Polyzene-F–coated coronary stents have shown reduced thrombogenicity and inflammation in preclinical studies. Methods Patients with de novo coronary artery lesions meeting eligibility criteria were enrolled in a nonrandomized, prospective clinical trial. The primary endpoint was target vessel failure (TVF) (defined as a composite of cardiac death, myocardial infarction, or clinically driven target vessel revascularization) at 9 months. A pre-spe…
Optical Coherence Tomography Versus Intravascular Ultrasound to Evaluate Coronary Artery Disease and Percutaneous Coronary Intervention
2013
ObjectivesWe compared intravascular ultrasound (IVUS) and 2 different generations of optical coherence tomography (OCT)—time-domain OCT (TD-OCT) and frequency-domain OCT (FD-OCT)—for the assessment of coronary disease and percutaneous coronary intervention (PCI) using stents.BackgroundOCT is a promising light-based intravascular imaging modality with higher resolution than IVUS. However, the paucity of data on OCT image quantification has limited its application in clinical practice.MethodsA total of 227 matched OCT and IVUS pull backs were studied. One hundred FD-OCT and IVUS pull backs in nonstented (n = 56) and stented (n = 44) vessels were compared. Additionally, 127 matched TD-OCT and …