Search results for "result"
showing 10 items of 2426 documents
Simultaneous measurement of the muon neutrino charged-current cross section on oxygen and carbon without pions in the final state at T2K
2020
Authors: K. Abe,56 N. Akhlaq,45 R. Akutsu,57 A. Ali,32 C. Alt,11 C. Andreopoulos,54,34 L. Anthony,21 M. Antonova,19 S. Aoki,31 A. Ariga,2 T. Arihara,59 Y. Asada,69 Y. Ashida,32 E. T. Atkin,21 Y. Awataguchi,59 S. Ban,32 M. Barbi,46 G. J. Barker,66 G. Barr,42 D. Barrow,42 M. Batkiewicz-Kwasniak,15 A. Beloshapkin,26 F. Bench,34 V. Berardi,22 L. Berns,58 S. Bhadra,70 S. Bienstock,53 S. Bolognesi,6 T. Bonus,68 B. Bourguille,18 S. B. Boyd,66 A. Bravar,13 D. Bravo Berguño,1 C. Bronner,56 S. Bron,13 A. Bubak,51 M. Buizza Avanzini ,10 T. Campbell,7 S. Cao,16 S. L. Cartwright,50 M. G. Catanesi,22 A. Cervera,19 D. Cherdack,17 N. Chikuma,55 G. Christodoulou,12 M. Cicerchia,24,† J. Coleman,34 G. Collazu…
Characterization of nuclear effects in muon-neutrino scattering on hydrocarbon with a measurement of final-state kinematics and correlations in charg…
2018
This paper reports measurements of final-state proton multiplicity, muon and proton kinematics, and their correlations in charged-current pionless neutrino interactions, measured by the T2K ND280 near detector in its plastic scintillator (C$_8$H$_8$) target. The data were taken between years 2010 and 2013, corresponding to approximately 6$\times10^{20}$ protons on target. Thanks to their exploration of the proton kinematics and of kinematic imbalances between the proton and muon kinematics, the results offer a novel probe of the nuclear-medium effects most pertinent to the (sub-)GeV neutrino-nucleus interactions that are used in accelerator-based long-baseline neutrino oscillation measureme…
Performance Management in the Public Sector
2018
Performance management is a management style aimed at setting goals and ensuring that such targets are achieved through a planning and control cycle. It embodies a set of activities, tools, and mechanisms intended to measuring and evaluating results to continuously improve performance.
Operational and financial effectiveness of e-collaboration tools in supply chain integration
2004
This paper develops a comprehensive model of supply chain integration and uses it to analyze and assess the operational and financial effectiveness of different e-collaboration tools at various levels of supply chain integration. This model is also used to evaluate the importance of the sequence in which e-collaboration tools are adopted in supply chain integration. Computational results from a validated system dynamics simulation model with different implementation sequences of e-collaboration tools and different financial scenarios show that local financial constraints can also severely impact operational and financial performance of the entire supply chain. (C) 2003 Elsevier B.V. All rig…
Market Impact and Trading Profile of Hidden Orders in Stock Markets
2009
We empirically study the market impact of trading orders. We are specifically interested in large trading orders that are executed incrementally, which we call hidden orders. These are statistically reconstructed based on information about market member codes using data from the Spanish Stock Market and the London Stock Exchange. We find that market impact is strongly concave, approximately increasing as the square root of order size. Furthermore, as a given order is executed, the impact grows in time according to a power law; after the order is finished, it reverts to a level of about 0.5-0.7 of its value at its peak. We observe that hidden orders are executed at a rate that more or less m…
Simultaneous determination of four 5-hydroxy polymethoxyflavones by reversed-phase high performance liquid chromatography with electrochemical detect…
2009
Accumulating evidence has suggested the potential health-promoting effects of 5-hydroxy polymethoxyflavones (5-OH-PMFs) naturally existing in citrus genus. However, research efforts are hampered by the lack of reliable and sensitive methods for their determination in plant materials and biological samples. Using reversed-phase high performance liquid chromatography (HPLC) equipped with electrochemical (EC) detection, we have developed a fast and highly sensitive method for quantification of four 5-OH-PMFs, namely 5-hydroxy-6,7,8,3',4'-pentamethoxyflavone, 5-hydroxy-3,6,7,8,3',4'-hexamethoxyflavone, 5-hydroxy-6,7,4'-trimethoxyflavone, and 5-hydroxy-6,7,8,4'-tetramethoxyflavone. The method wa…
Target analysis and retrospective screening of veterinary drugs, ergot alkaloids, plant toxins and other undesirable substances in feed using liquid …
2015
A comprehensive strategy combining a quantitative method for 77 banned veterinary drugs, mycotoxins, ergot alkaloids and plant toxins, and a post-target screening for 425 substances including pesticides and environmental contaminants in feed were developed using a QuEChERS-based extraction and an ultra-high performance liquid chromatography coupled to high-resolution mass spectrometry (UHPLC-HRMS). The quantitative method was validated after previous statistical optimisation of the main parameters governing ionisation, and presented recoveries ranging, in general, from 80 to 120%, with a precision in terms of Relative Standard Deviation (RSD) lower than 20%. The full-scan accurate mass data…
Flow injection spectrophotometric determination of lead using 1,5-diphenylthiocarbazone in aqueous micellar
2009
A simple flow injection colorimetric procedure for determining lead was established. It is based on the reaction of lead in sulfuric acid with 1,5-diphenylthiocarbazone and sodium dodecyl sulfate, resulting in an intense red-blue complex with a suitable absorption at 500 nm. A standard or sample solution was injected into the sulfuric acid stream (flow rate of 2.0 ml min(-1)), which was then merged with sodium dodecyl sulfate stream (flow rate of 2.0 ml min(-1)) and 1,5-diphenylthiocarbazone stream (flow rate of 1.5 ml min(-1)). Optimum conditions for determining lead were investigated by univariate method. Under the optimum conditions, a linear calibration graph was obtained over the range…
Sensitive determination of polycyclic aromatic hydrocarbons in water samples using monolithic capillary solid-phase extraction and on-line thermal de…
2011
A methacrylate-based monolithic capillary column has been evaluated for the preconcentration of polycyclic aromatic hydrocarbons (PAHs) from environmental water samples. For this purpose, the monolyte was in situ synthesized in a 6cm×0.32mm id fused-silica capillary. The microextraction unit was fitted to a micro-HPLC pump to pass 10mL of sample. The isolated pollutants were eluted by means of 10μL of methanol, the organic phase being directly collected in a specific interface that can be fitted to the injection port of the gas chromatograph without modification. The interface allows the on-line thermal desorption of the PAHs, avoiding the dilution and providing enough sensitivity to reach …
Protein diffusion in mammalian cell cytoplasm.
2011
We introduce a new method for mesoscopic modeling of protein diffusion in an entire cell. This method is based on the construction of a three-dimensional digital model cell from confocal microscopy data. The model cell is segmented into the cytoplasm, nucleus, plasma membrane, and nuclear envelope, in which environment protein motion is modeled by fully numerical mesoscopic methods. Finer cellular structures that cannot be resolved with the imaging technique, which significantly affect protein motion, are accounted for in this method by assigning an effective, position-dependent porosity to the cell. This porosity can also be determined by confocal microscopy using the equilibrium distribut…