Search results for "result"

showing 10 items of 2426 documents

MR-imaging features of hepatocellular carcinoma capsule appearance in cirrhotic liver: comparison of gadoxetic acid and gadobenate dimeglumine.

2016

Purpose: The purpose of the study is to compare the MR-imaging features of hepatocellular carcinoma (HCC) capsule appearance on gadoxetic acid and gadobenate dimeglumine-enhanced MR imaging, using imaging-based presumptive diagnosis of HCC as the reference standard. Methods: Gadoxetic acid and gadobenate dimeglumine-enhanced MR imaging of 51 patients with 71 HCCs were retrospectively reviewed. Three readers graded in consensus, using a five-point scale, the presence (score 4–5) of capsule appearance on images obtained during T1-weighted GRE portal venous phase (PVP), 3-min phase, and hepatobiliary phase (HBP). The Fisher's exact test and the t student unpaired test were performed. Results: …

Gadolinium DTPALiver CirrhosisMaleCirrhotic livermedicine.medical_specialtyGadoxetic acidCarcinoma HepatocellularHepatocellular carcinomaUrologyGadoxetic acidContrast MediaSensitivity and Specificity030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineMeglumineInternal medicineGadobenate dimegluminemedicineOrganometallic CompoundsHumansRadiology Nuclear Medicine and imagingGADOBENATE DIMEGLUMINECapsuleAgedRetrospective StudiesAged 80 and overRadiological and Ultrasound Technologybusiness.industryLiver NeoplasmsGastroenterologyCapsuleReproducibility of ResultsHepatologyHCCSMiddle Agedmedicine.diseaseImage EnhancementMr imagingMagnetic Resonance Imagingdigestive system diseasesLiver030220 oncology & carcinogenesisHepatocellular carcinomaFemaleRadiologybusinessMR imagingmedicine.drugAbdominal radiology (New York)
researchProduct

Liver Imaging Reporting and Data System (LI-RADS) v2018: diagnostic value of ancillary features favoring malignancy in hypervascular observations ≥ 1…

2020

This study was conducted in order to assess the diagnostic accuracy of LI-RADS v2018 ancillary features (AFs) favoring malignancy applied to LR-3 and LR-4 observations on gadoxetate-enhanced MRI. In this retrospective dual-institution study, we included consecutive patients at high risk for hepatocellular carcinoma (HCC) imaged with gadoxetate disodium-enhanced MRI between 2009 and 2014 fulfilling the following criteria: (i) at least one LR-3 or LR-4 observation ≥ 10 mm; (ii) nonrim arterial phase hyperenhancement; and (iii) confirmation of benignity or malignancy by pathology or imaging follow-up. We compared the distribution of AFs between HCCs and benign observations and the diagnostic p…

Gadolinium DTPAMalemedicine.medical_specialtyCirrhosisMultivariate analysisCarcinoma HepatocellularContrast MediaMalignancy030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinemedicineHumansRadiology Nuclear Medicine and imagingNeuroradiologyRetrospective Studiesmedicine.diagnostic_testbusiness.industryBenignityLiver NeoplasmsReproducibility of ResultsMagnetic resonance imagingGeneral MedicineMiddle Agedmedicine.diseaseMagnetic Resonance ImagingHyperintensityResearch Design030220 oncology & carcinogenesisHepatocellular carcinomaFemaleRadiologybusinessSettore MED/36 - Diagnostica Per Immagini E RadioterapiaCirrhosis Magnetic resonance imaging Hepatocellular carcinoma LiverEuropean radiology
researchProduct

Role of Cardiac Magnetic Resonance Imaging in the Detection of Cardiac Amyloidosis

2010

Objectives Our aim was to evaluate the role and mechanism of late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) in identifying cardiac amyloidosis (CA) and to investigate associations between LGE and clinical, morphologic, functional, and biochemical features. Background CA can be challenging to diagnose by echocardiography. Recent studies have demonstrated an emerging role for LGE-CMR. Methods LGE-CMR was performed in 120 patients with amyloidosis. Cardiac histology was available in 35 patients. The remaining 85 patients were divided into those with and without echocardiographic evidence of CA. Results Of the 35 patients with histologically verified CA, abnormal LGE was pre…

Gadolinium DTPAMalemedicine.medical_specialtyPathologymedicine.drug_classBiopsyCardiomyopathyContrast MediaMagnetic Resonance Imaging CineSeverity of Illness IndexElectrocardiographyCardiac magnetic resonance imagingPredictive Value of TestsInternal medicineBiopsymedicineNatriuretic peptideHumansRadiology Nuclear Medicine and imagingcardiovascular diseasesAgedRetrospective StudiesUltrasonographyObserver VariationChi-Square Distributionmedicine.diagnostic_testbusiness.industryAmyloidosisMyocardiumReproducibility of ResultsMagnetic resonance imagingAmyloidosisMiddle Agedmedicine.diseasePrognosisSettore MED/11 - Malattie Dell'Apparato CardiovascolareMAGNETIC RESONANCE CARDIAC AMYLOIDOSIS.Early DiagnosisCardiac amyloidosisRadiology Nuclear Medicine and imagingembryonic structurescardiovascular systemCardiologyFemalebusinessCardiomyopathiesCardiology and Cardiovascular MedicineElectrocardiographyBiomarkersJACC: Cardiovascular Imaging
researchProduct

Quantification of pulmonary blood flow (PBF): validation of perfusion MRI and nonlinear contrast agent (CA) dose correction with H(2)15O positron emi…

2009

Validation of quantification of pulmonary blood flow (PBF) with dynamic, contrast-enhanced MRI is still missing. A possible reason certainly lies in difficulties based on the nonlinear dependence of signal intensity (SI) from contrast agent (CA) concentration. Both aspects were addressed in this study. Nine healthy pigs were examined by first-pass perfusion MRI using gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) and HO positron emission tomography (PET) imaging. Calculations of hemodynamic parameters were based on a one-compartment model (MR) and a two-compartment model (PET). Simulations showed a significant error when assuming a linear relation between MR SI and CA dose in the …

Gadolinium DTPAPulmonary CirculationCalibration curveSwinemedia_common.quotation_subjectGadoliniumPerfusion ImagingHemodynamicschemistry.chemical_elementContrast MediaSensitivity and SpecificityStandard deviationOxygen RadioisotopesmedicineContrast (vision)AnimalsRadiology Nuclear Medicine and imagingmedia_commonmedicine.diagnostic_testbusiness.industryReproducibility of ResultsWaterMagnetic resonance imagingImage EnhancementchemistryPositron emission tomographyPositron-Emission TomographyRadiopharmaceuticalsNuclear medicinebusinessArtifactsPerfusionMagnetic Resonance AngiographyMagnetic resonance in medicine
researchProduct

Implementation and microbiological stability of dose-banded ganciclovir infusion bags prepared in series by a robotic system.

2018

Objectives The implementation of dose-banding (DB) in centralised, pharmacy-based cytotoxic drug preparation units allows the preparation of standardised doses in series. The aim of this study was to evaluate the feasibility of DB for the prescribing of ganciclovir (GV) infusion solutions and to investigate the microbiological stability of dose-banded, automatically prepared ready-to-administer GV infusion bags by media-fill simulation tests and sterility tests. Methods The frequency of prescription of GV doses was retrospectively analysed before and after implementing the DB scheme. Four dose-ranges or ‘bands’ and the corresponding standard doses (250, 300, 350, 400 mg) were identified. Th…

GanciclovirCytotoxic drugSterilityDrug CompoundingDrug StorageGrowth promotion030226 pharmacology & pharmacyAntiviral AgentsStandard PreparationsExtended storage03 medical and health sciences0302 clinical medicineAnimal scienceDrug StabilityRefrigerationMedicineInfusions Parenteral030212 general & internal medicineGeneral Pharmacology Toxicology and PharmaceuticsGanciclovirDrug PackagingRetrospective StudiesOriginal Researchbusiness.industryReproducibility of ResultsRoboticsRobotic systemsAseptic processingbusinessDrug ContaminationPharmacy Service Hospitalmedicine.drugEuropean journal of hospital pharmacy : science and practice
researchProduct

Analytical procedures for short chain chlorinated paraffins determination - How to make them greener?

2019

Abstract The aim of the following paper was to gather current scientific information about the analytical protocols dedicated to measuring the content level of short-chain chlorinated paraffins (SCCPs) in various types of environmental samples. Moreover, the data about the basic validation parameters of applied procedures for SCCPs determination are listed. The main issue which is highlighted in the paper is the possibility of the application of green analytical chemistry (GAC) principals in the SCCPs measuring process to reduce the environmental impact of the applied methodology. Analytical methods dedicated to SCCPs determination contain a significant number of steps and require advanced …

Gas chromatographyEnvironmental Engineering010504 meteorology & atmospheric sciencesComputer scienceProcess (engineering)Green analytical chemistrymedia_common.quotation_subjectSample preparation techniquesShort-chain chlorinated paraffins010501 environmental sciences01 natural sciencesPollutionResults qualityQualitative analysisChlorinated paraffinsEnvironmental samplesEnvironmental ChemistryAnalytical proceduresQuality (business)Biochemical engineeringWaste Management and DisposalReliability (statistics)0105 earth and related environmental sciencesmedia_commonThe Science of the total environment
researchProduct

Value of gastrin-17 in detecting antral atrophy.

2011

Decreased plasma gastrin-17 (G-17), particularly after protein stimulation, is indicative of atrophy in the antral stomach mucosa. Available data on the value of this biomarker is inconclusive. Our study was aimed to evaluate the performance of the G-17 test in Caucasian and Asian patients for antral atrophy evaluation either in fasting state or after protein stimulation.241 dyspeptic patients aged 55 and above from Latvia (125), Lithuania (76) and Taiwan (40) were enrolled. G-17 levels were detected in plasma samples obtained either during fasting or after a protein-rich test meal. Levels1 pmol/L at fast and5 pmol/L after stimulation were considered indicative of atrophy.The sensitivity of…

Gastritis AtrophicMalemedicine.medical_specialtyAtrophic gastritisStimulationGastroenterologySensitivity and SpecificityAtrophyPredictive Value of TestsInternal medicineGastrinsmedicineBiomarkers TumorHumansAntrumAgedAged 80 and overbusiness.industryStomachReproducibility of ResultsGeneral MedicineMiddle Agedmedicine.diseaseEndocrinologymedicine.anatomical_structureGastric MucosaPredictive value of testsBiomarker (medicine)FemaleDietary ProteinsGastritismedicine.symptomAtrophybusinessAdvances in medical sciences
researchProduct

Determination of molecular mass, Stokes' radius, frictional coefficient and isomer-type of non-denatured proteins by time-dependent pore gradient gel…

1988

Molecular mass, Stoke's radius, frictional coefficient and isomer-type of non-denatured proteins can be obtained by time-dependent gradient gel electrophoresis by evaluating the resulting data using a two-step mathematical procedure. Provided a histochemical staining procedure is available to locate the position of an enzyme in the gel, crude cell extracts can be used for estimating their molecular size properties. The computation of molecular properties of non-denatured proteins is demonstrated for isozymes of aspartate aminotransferase (EC 2.6.1.1), peroxidase (EC 1.11.1.42) and glucose-6-phosphate dehydrogenase (EC 1.1.1.49) from current-year needles of spruce. The resulting data as well…

Gel electrophoresisShikimate dehydrogenaseChromatographyMolecular massChemistryGlutamate dehydrogenaseClinical BiochemistryReproducibility of ResultsDehydrogenaseEnvironmental pollutionStereoisomerismBiochemistryCatalysisAnalytical ChemistryEnzymesMolecular WeightCalibrationElectrophoresis Polyacrylamide GelPolyacrylamide gel electrophoresisStokes radiusPlant ProteinsElectrophoresis
researchProduct

Multicenter evaluation of a second-generation assay for cardiac troponin T.

1997

Abstract We report on the evaluation of the second-generation assay for cardiac troponin T (cTnT) on the Enzymun®system. This new assay is completely specific for the cardiac isoform of TnT, utilizing two cardiospecific monoclonal antibodies. The assay time is reduced to 45 min. The interassay precision shows a median CV of 5.5%; 20% interassay CV was found between 0.05 and 0.1 μg/L. The cardiosensitivity of the second-generation cTnT assay in patients with ischemic myocardial injury appears equivalent when compared with the first-generation assay. We found no falsely positive results in patients with skeletal muscle damage including multitraumas, surgery patients, and marathon runners who …

Gene isoformmedicine.medical_specialtyCardiac troponinHeart diseasemedicine.drug_classClinical BiochemistryMyocardial IschemiaMonoclonal antibodySensitivity and SpecificityTroponin complexTroponin TInternal medicinemedicineHumansMuscle SkeletalbiologyTroponin Tbusiness.industryMyocardiumBiochemistry (medical)Skeletal muscleReproducibility of Resultsmedicine.diseaseTroponinTroponinmedicine.anatomical_structureEndocrinologyCardiologybiology.proteinbusinessArtifactsTroponin CBiomarkersClinical chemistry
researchProduct

Exact results for accepting probabilities of quantum automata

2001

One of the properties of Kondacs-Watrous model of quantum finite automata (QFA) is that the probability of the correct answer for a QFA cannot be amplified arbitrarily. In this paper, we determine the maximum probabilities achieved by QFAs for several languages. In particular, we show that any language that is not recognized by an RFA (reversible finite automaton) can be recognized by a QFA with probability at most 0.7726...

General Computer ScienceFOS: Physical sciences0102 computer and information sciences02 engineering and technologyUnitary transformationComputer Science::Computational Complexity01 natural sciencesTheoretical Computer ScienceCombinatoricsQuantum measurementFormal languageQuantum computation0202 electrical engineering electronic engineering information engineeringQuantum finite automataMathematicsQuantum computerQuantum PhysicsFinite-state machineMarkov chainExact resultsTransformation (function)010201 computation theory & mathematics020201 artificial intelligence & image processingQuantum Physics (quant-ph)Finite automataComputer Science::Formal Languages and Automata TheoryComputer Science(all)Theoretical Computer Science
researchProduct